1 September 2014 in Surface and Coatings Technology
State of the art packaging for implantable devices uses metal or glass housings that are reliable but limited from a miniaturisation viewpoint as well as cost-intensive. We suggest a hermetic and biocompatible thin film packaging based on alternating organic/inorganic coatings for further miniaturisation of smart implantable MEMS devices that can be applied for long-term implantation. The combination of high intrinsic molecular density silicon oxide (SiOx) and pinhole-free and stress releasing poly-para-xylylene (parylene-C) thin films creates a new composite material, which is optimal for hermetic and biocompatible packaging. A novel single-chamber thin film deposition process was developed for the fabrication of SiOx/parylene thin film multilayer structures, using a modified chemical vapour deposition (CVD) process. According to permeation and conformity aspects, the inorganic layer is the crucial layer of the coating. Permeation measurements the highly ceramic SiOx material revealed a low helium gas permeation and a non-critical cracking thickness up to 300nm. The morphology of the multilayer structure was analysed by scanning electron microscopy; an algorithm for defining ideal layer conformity was established and no local thickness deficiencies of deposited SiOx layers could be observed. To evaluate the corrosion protection, an adapted calcium mirror test based on water droplet permeation was developed, and the water permeation of conventional parylene-C layers (4.5μm) was compared to multilayer stacks composed of 3 SiOx interlayers (4.7μm).In this paper, it could be shown that by tailoring the thickness ratio between the involved layers, the percolative pathway and thereby, the permeation for direct water exposure could be considerably reduced compared to conventional parylene-C single layers with the same thickness
5 April 2016 in Optics Express
This paper presents a Fabry-Perot fiber tip sensor based on an air-liquid filled cavity. The cavity is sealed off by a thin gold coated membrane of parylene C, between 300 and 350 nm, creating a particularly flexible diaphragm. In order to retrieve and track the cavity of interest from other cavities formed within the sensor tip, a signal processing of the feedback signal is performed by inverse fast Fourier transform. The experimental sensor has been manufactured and tested for temperature, giving cavity length sensitivities of 6.1 nm/°C and 9.6 nm/°C for temperature increase and decrease respectively. The external gas pressure response gives a sensitivity of 15 nm/kPa. The fiber sensor has also been adapted for force sensing after silicone embedment and has shown a sensitivity of about 8.7 nm/mN. Finally, the sensor has been tested on insertion into a human temporal bone, proving that it could be an interesting candidate for insertion force monitoring for robotic cochlear implantation.
1 January 1994 in MRS Proceedings
1 February 2015 in Surface and Coatings Technology
RBRina Ben Shabat Binyamini
Rina Ben Shabat Binyamini
1 August 2009 in Journal of Physics: Conference Series