Zhile Lin

Zhile Lin

Auto-generated profile, based on publicly available information

Zhile Lin

College of Electrical Engineering and Automation, Xiamen University of Technology, Xiamen 361024, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HZHongyan Zhou
Hongyan Zhou
LHLiangzhong He
Liangzhong He
ZLZhile Lin
Zhile Lin
The instantaneous output power of the two-stage single-phase inverter pulsates at double-line frequency, generating a large amount of second harmonic current (SHC) in the front-end dc-dc converter and input dc source. The SHC is harmful to the system performance. To address the issue, a control strategy based on port-impedance editing, where inductor current feedforward (ICFF) and bus voltage feedforward paths are employed, is proposed to reduce the low frequency ripple in the article. Due to only bandpass filter employed in each feedforward path, the proposed control scheme is relatively easy to be implemented. Under the control strategy, the dc-bus port-impedance of dc-dc converter is increased rapidly at double-line frequency, while staying low impedance for other frequencies. What is more, different ICFF paths are taken into insight to obtain optimized path. Meanwhile, the small signal model of front-end dc-dc converter is established and the design principle of key parameters is provided for the derived control strategy. Furthermore, the dynamic response with bandwidth limitation is also discussed in this article. Finally, a two-stage single-phase inverter prototype was fabricated and tested. The experimental results verify the performance of the proposed strategy with SHC reduction.

28 February 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZLZhile Lin
Zhile Lin
LHLiangzhong He
Liangzhong He
HZHongyan Zhou
Hongyan Zhou
In microgrid system, current in dc bus may contain a lot of undesired low-order harmonics when converters are employed, especially the second harmonic current (SHC). To address the issue, this article proposes a method based on fractional-order capacitor (FOC) to suppress the SHC. The FOC, of which the order α is “−1,” has the same characteristics of dc blocking and ac conducting as conventional capacitor; while it can resonate with a conventional capacitor like an inductor, which could be called a negative-order capacitor (NOC) as well. The proposed circuit has good SHC suppression performance, faster dynamic response, and soft switching realization. It parallels on the dc side of an inverter instead of the large bus capacitor, increasing power density and reducing design cost and loss.The secondary power will only circuit between the ac side of inverter and the NOC circuit. In addition, the NOC circuit can adjust zero impedance to specific harmonics; so it can be expanded to suppress harmonic current at other frequencies in the system. The simulation and experimental results are presented to validate the feasibility of the proposed method.

9 October 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HZHongyan Zhou
Hongyan Zhou
LHLiangzhong He
Liangzhong He
ZYZelong Yang
Zelong Yang
ZLZhile Lin
Zhile Lin
In a two-stage single-phase inverter, the pulsating output power generates a second harmonic current (SHC) at the dc port. Although the conventional virtual-resistor (VR) based control method can suppress the SHC, the SHC reduction performance is limited by its dynamic performance. To address the above issues, based on the unified small-signal model of the dc–dc converter, a virtual fractional-order-inductor (FOI) based control method is proposed in this article to reduce the SHC and improve the system dynamic performance. The order and magnitude of the fractional-order inductor can be modified arbitrarily. A negative order inductor is constructed in this article to reduce the SHC and improve the system dynamic performance. In addition, the proposed virtual FOI-based control method can improve the stability of both dc–dc converter and the cascaded system. The comparison of the proposed fractional-order inductor and conventional VR-based control method is given and the design method of key parameters is presented. Finally, an 800-W two-stage single-phase inverter with the upstream boost converter is fabricated and tested in the laboratory to verify the effectiveness of the proposed control method.

8 August 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZLZhile Lin
Zhile Lin
LHLiangzhong He
Liangzhong He
HZHongyan Zhou
Hongyan Zhou
JZJingyu Zhang
Jingyu Zhang
ZXZhenkun Xiong
Zhenkun Xiong
In a microgrid system, the dc bus contains a significant amount of undesired low-order harmonic currents (LHC) when multiple converters of various types and with nonlinear behavior are connected. To address the issue, this article proposes an iterative control strategy based on a negative-order capacitor (NOC) branch on dc bus. In the proposed method, the reference voltage of decoupling capacitors in the NOC circuit is obtained based on the dc bus current. The voltage difference between the two decoupling capacitors is taken as the control objective, leaving little dc difference between the two capacitors and resulting in maximum LHC suppression ability. To refactor the reference voltage, a singularity points hunting strategy is proposed, helping to reduce the current spike. More importantly, the iterative control strategy is employed in the virtual current loop, decreasing steady-state error from device deviation or control deviation. Finally, an 800 W prototype is built to validate the effectiveness of the proposed method.

25 July 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZLZhile Lin
Zhile Lin
LHLiangzhong He
Liangzhong He
HZHongyan Zhou
Hongyan Zhou
In a microgrid system, the current in the dc bus may contain undesired low-order harmonics when multiple converters are employed. The integer negative order capacitor has been verified to be an effective method. However, the performance of harmonic suppression may deteriorate because of the parameter error. To address the issue, this article proposes an adaptive fractional-order capacitor (FOC) based method, in which the order of the capacitor can be modulated, depending on the impedance needed to be compensated. The terminal voltage of adaptive FOC is determined by the external circuit while the current can be adjusted freely, thus, different port impedance characteristics can be performed. The method uses a capacitor as its power storage instead of a dc supply and has nondissipative components to bring no additional loss. To stabilize the internal energy of the adaptive FOC circuit and make the port current accurate, a parallel double closed-loop control is employed. And the parameter error can be calculated from the harmonic content of the bus current. The simulation and experimental results are presented to validate the feasibility of the proposed method. The proposed method opens up an avenue for expanding the application of asymmetric parameter systems.

8 November 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JZJingyu Zhang
Jingyu Zhang
LHLiangzhong He
Liangzhong He
ZLZhile Lin
Zhile Lin
The problem of the second harmonic current (SHC) on the dc bus side of the single-phase inverter system has attracted widespread attention. The active power decoupling method based on dual capacitors can suppress SHC effectively. However, the asymmetrical capacitor parameters will deteriorate the SHC suppression performance and lead to the first-order harmonic current. To eliminate these low-order harmonic currents, this article proposes a SHC suppression method based on the fractional-order capacitor (FOC), where no power supply is employed and little loss is incurred. The capacitance and the order of the proposed FOC can, both, be adjusted. The principle and operating mode of the FOC are analyzed, and the control strategy of adjustment is given. The method can realize the SHC suppression with the advantages of a simple control strategy, hot-swappable, and high flexibility. Most importantly, the method can effectively suppress the first-order harmonic current caused by the asymmetrical parameters of the capacitors. Finally, an 800 W prototype based on the proposed method is built, and the simulation and experimental results both verify the effectiveness of the proposed method.