A novel high step-up DC-DC converter with coupled-inductor and switched-capacitor is proposed in the paper, which is widely used in the renewable energy system as the front-end stage for low voltage source. The combinational employment of switched-capacitor and coupled-inductor makes high voltage gain achievable without extreme duty cycle, resulting in reduced voltage stress on power switches. Hence, MOSFETs with low resistance RDS(ON) could be utilized as the main switch to reduce conduction loss. Meanwhile, due to the leakage inductance of coupled inductor, the current falling rate becomes controllable and reverse-recovery problem of output diode is alleviated. Importantly, by incorporating active clamped-circuit, not only voltage spike caused by leakage inductance is restrained, but also zero-voltage switching(ZVS) could be obtained for the main and auxiliary switches. Specially, the clamped-circuit plays a role of energy transfer to boost the gain as well. Finally, a prototype with power rating of 500W is implemented to verify the performance of the proposed converter.
26 October 2018 in IEEE Transactions on Power Electronics
In high gain voltage conversion applications, the low-side switches usually suffer large current stress, resulting in dominate switching loss. In the paper, a general soft-switching method based on an advanced interleaved high-step-up converter, which features excellent performance but works in hard-switching, is presented to combat this issue by using a plug-play resonant circuit. Under this soft-switching method, the main switches reach zero-voltage-switching (ZVS) turn-on and ZVS turn-off, and the soft-switching condition is derived. Meanwhile, the added auxiliary switches could be turned off under ZVS condition and turned on under zero-current-switching (ZCS) condition as well. More importantly, due to its location out of the energy transferring path, the auxiliary circuit will never lead gain lost to the converter and maintain its other existing merits such as current auto-balancing and diode inverse-recovery well. A 1 kW prototype is built and tested to verify the significant efficiency improvement and merits maintenance for the proposed converter considering active resonant soft-switching.
The coulomb counting (CC) approach is widely used in SOC estimation due to its simplicity and low calculation cost. However, in practical applications, the lack of error correction ability limits its accuracy due to the measured noise in the practical occasion. To address the issue, an improved CC (ICC) approach based on numerical iteration is proposed in this paper. In the proposed approach, a battery model based on a 2nd-order, RC circuit is first formulated to determine the SOC-OCV curve, R-OCV curve, and inner parameters. In the model, the slow dynamic and fast dynamic voltages are described separately, and are utilized for battery state assessment. Then, the SOC will be estimated by the CC approach at the unsteady state but through a numerical iteration approach at steady state. Consequently, the accumulative SOC error from the CC approach will be corrected when the numerical iteration approach is applied. Furthermore, a compensation coefficient is employed into the CC approach to reduce the error accumulation rate. Hence, the proposed ICC approach could make full use of the advantages of conventional CC in low computational demand and numerical iteration approach in error correction. Finally, an experiment platform was built, where two kinds of current sensors with different measuring accuracy were employed to simulate the measured current with and without noise, respectively. The experimental results suggest that the accumulative SOC error can be corrected in real-time and the SOC error is reduced to 1%. The error accumulation rate of SOC is effectively reduced compared with traditional CC approach, simultaneously, more than 90% of the calculation time can be reduced compared with EKF.
19 October 2017 in IEEE Transactions on Industrial Electronics
This paper extends the trans-Z-source concept to ac-ac power conversion and proposes a novel single-phase trans-Z-source ac-ac converter. The proposed converter retains the advantages of its existing Z-source/quasi-Z-source counterparts in which the output voltage can be boosted and in-phase with the input voltage or bucked/boosted and out-of-phase with the input voltage. Meanwhile, a coupled inductor is introduced into the proposed converter, and the turns ratio of the coupled inductor become another control variable beside the duty cycle to obtain extreme voltage gain. Importantly, the input voltage and output voltage share the same ground, and the input current could be continuous, which is a benefit for reducing input current harmonics. Most important of all, the safe-commutation strategy for the proposed converter is deep developed, and analytic expression between the switches state and loop circuit voltage/current condition is derived out. Hence, the current/voltage ripple can be avoided without a loss snubber circuit, which benefits a reduced cost and enhanced reliability. The performance analysis is discussed in consideration of parasitic resistance, and system parameter design is optimized based on theoretic calculation. A laboratory prototype is fabricated, and experiments are performed to verify the validation of the proposed converter.
18 December 2017 in IEEE Transactions on Industrial Electronics
Microinverters operating into the single-phase grid from new energy source with low-voltage output face the challenges of efficiency bottleneck and twice-line-frequency variation. This paper proposed a multilevel inverter based on bridge modular switched-capacitor (BMSC) circuits with its superiority in conversion efficiency and power density. The topology is composed of dc-dc and dc-ac stages with independent control for each stage, aiming to improve system stability and simplify the control method. The BMSC dc-dc stage, which can be expanded to synthesize more levels, not only features multilevel voltage gain but also partially replaces the original bulk input capacitor and functions as an active energy buffer to enhance power-decoupling ability between dc and ac sides. In dc-ac stage, the control strategy of optimized unipolar frequency doubling sine-wave pulse width modulation is proposed to improve the quality of output waveform. Meanwhile, the multilevel voltage phase has been optimized to further reduce the power loss. Finally, a prototype has been built and tested. Associated with the simulation, the experimental results validate the practicability of these analyses.
2 December 2021 in IEEE Transactions on Industrial Electronics
The instantaneous output power of the two-stage single-phase inverter pulsates at double-line frequency, generating a large amount of second harmonic current (SHC) in the front-end dc-dc converter and input dc source. The SHC is harmful to the system performance. To address the issue, a control strategy based on port-impedance editing, where inductor current feedforward (ICFF) and bus voltage feedforward paths are employed, is proposed to reduce the low frequency ripple in the article. Due to only bandpass filter employed in each feedforward path, the proposed control scheme is relatively easy to be implemented. Under the control strategy, the dc-bus port-impedance of dc-dc converter is increased rapidly at double-line frequency, while staying low impedance for other frequencies. What is more, different ICFF paths are taken into insight to obtain optimized path. Meanwhile, the small signal model of front-end dc-dc converter is established and the design principle of key parameters is provided for the derived control strategy. Furthermore, the dynamic response with bandwidth limitation is also discussed in this article. Finally, a two-stage single-phase inverter prototype was fabricated and tested. The experimental results verify the performance of the proposed strategy with SHC reduction.