Aisheng Wu

Aisheng Wu

Auto-generated profile, based on publicly available information

Aisheng Wu

Science Systems and Applications, Inc. (United States)

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2014 in Remote Sensing
Verified
Journal Article
Open access
PDF file
RBRajendra Bhatt
Rajendra Bhatt
DDDavid Doelling
David Doelling
AWAisheng Wu
Aisheng Wu
XXXiaoxiong Xiong
Xiaoxiong Xiong
BSBenjamin Scarino
Benjamin Scarino
AGArun Gopalan
Arun Gopalan
The latest CERES FM-5 instrument launched onboard the S-NPP spacecraft will use the VIIRS visible radiances from the NASA Land Product Evaluation and Analysis Tool Elements (PEATE) product for retrieving the cloud properties associated with its TOA flux measurement. In order for CERES to provide climate quality TOA flux datasets, the retrieved cloud properties must be consistent throughout the record, which is dependent on the calibration stability of the VIIRS imager. This paper assesses the NASA calibration stability of the VIIRS reflective solar bands using the Libya-4 desert and deep convective clouds (DCC). The invariant targets are first evaluated for temporal natural variability. It is found for visible (VIS) bands that DCC targets have half of the variability of Libya-4. For the shortwave infrared (SWIR) bands, the desert has less variability. The brief VIIRS record and target variability inhibits high confidence in identifying any trends that are less than ±0.6%/yr for most VIS bands, and ±2.5%/yr for SWIR bands. None of the observed invariant target reflective solar band trends exceeded these trend thresholds. Initial assessment results show that the VIIRS data have been consistently calibrated and that the VIIRS instrument stability is similar to or better than the MODIS instrument.

13 November 2003
Verified
Conference Paper
Closed access
PDF file
AWAisheng Wu
Aisheng Wu
CCChangyong Cao
Changyong Cao
XXXiaoxiong Xiong
Xiaoxiong Xiong
Nearly identical copies of the MODerate Resolution Imaging Spectroradiometer (MODIS) are currently operating onboard the NASA s Earth Observing System (EOS) Terra and Aqua satellites launched on December 18, 1999 and on May 04, 2002 respectively. MODIS has 36 spectral bands with wavelengths from 0.41 to 14.5 μm. Bands 1 - 19 and 26 are the reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.2 μm and bands 20 - 25 and 27 - 36 are the thermal emissive bands (TEB) with spectral wavelengths above 3.5 μm. The two latest Advanced Very High Resolution Radiometer (AVHRR) instruments were launched onboard the NOAA-16 and NOAA-17 on September 21, 2000 and on June 24, 2002 respectively. The new AVHRR/3 instrument (onboard NOAA-15 to -17) is a six-channel imaging radiometer in the visible and infrared spectral region. There have been many important parameters and science products derived from observations made by both MODIS (more data products) and AVHRR (longer data record). In this paper, we present an inter-comparison of the 11 μm and 12 μm bands of the Terra and Aqua MODIS (bands 31 and 32) using the NOAA-17 AVHRR (channels 4 and 5). The AVHRR is served as an intermediate transfer vehicle. The intercomparison data sets from the MODIS and AVHRR are selected from nearly simultaneous observations (within 30 seconds) over relatively uniform scenes near the instrument nadir view with pixel-by-pixel matches in the Polar region. Preliminary results show that the measured temperature differences between the Terra and Aqua MODIS at 11 μm and 12 μm are about 0.25 K and 0.35 K at a brightness temperature of about 250 K, indicating consistent and reliable on-board calibration and characterization for the MODIS instruments. Using the same approach this paper also presents the results from comparing the NOAA-16 and 17 AVHRR 11 μm and 12 μm channels. At a brightness temperature range from 240 to 270 K, the observations show that the NOAA-17 AVHRR is about 0.45 K cooler than the NOAA-16 AVHRR for its 11 μm and 12 μm channels.

20 October 2009 in International Journal of Remote Sensing
Verified
Journal Article
Closed access
AWAisheng Wu
Aisheng Wu
XXXiaoxiong Xiong
Xiaoxiong Xiong
CCChangyong Cao
Changyong Cao
The NOAA-KLM satellites (NOAA-15 to 18) are the current polar-orbiting operational environmental satellites (POES) that carry the Advanced Very High Resolution Radiometer (AVHRR). This study examines the calibration stability and consistency of all three infrared channels (3.7, 11.0 and 12.0 μm) of AVHRR onboard NOAA-15 to 18. The short-term stability is examined from variations of the scan-by-scan gain response, while the long-term stability and calibration consistency are examined by tracking the trends of gain response and measured scene brightness temperatures. The relative differences of observed scene brightness temperatures among NOAA-15 to 18 AVHRR are determined using MODIS as a transfer radiometer based on observations from simultaneous nadir overpasses (SNO). Results show that variations of the scan-to-scan gain responses are within 0.10% under normal operational conditions, while long-term gain changes over six years from 2001 to 2006 vary from 2 to 4% depending on channel. Long-term trending results show that total six-year drifts in observed brightness temperature from NOAA-15 to 18 AVHRR are less than 0.5 K for a given scene temperature in the 250 to 270 K range for the 3.7, 11.0 and 12.0 μm channels, respectively. The calibration consistency is examined for a scene temperature range of 220 to 290 K. The temperature biases among NOAA-16 to 18 AVHRR are within ±0.5 K for the 11.0 and 12.0 μm channels. For NOAA-15 AVHRR, biases of –2.0 K at 11.0 μm and –1.5 K at 12.0 μm are found in comparison with others at the low end of the temperature range. For the 3.7 μm channel, relative biases up to a few degrees among NOAA-15 to 18 could be found at low brightness temperatures.

2 February 2011 in International Journal of Remote Sensing
Verified
Journal Article
Closed access
AWAisheng Wu
Aisheng Wu
XXXiaoxiong Xiong
Xiaoxiong Xiong
AAA. Angal
A. Angal
WBW. Barnes
W. Barnes
The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the five Earth-observing instruments on-board the National Aeronautics and Space Administration (NASA) Earth-Observing System (EOS) Terra spacecraft, launched in December 1999. It has 36 spectral bands with wavelengths ranging from 0.41 to 14.4 μm and collects data at three nadir spatial resolutions: 0.25 km for 2 bands with 40 detectors each, 0.5 km for 5 bands with 20 detectors each and 1 km for the remaining 29 bands with 10 detectors each. MODIS bands are located on four separate focal plane assemblies (FPAs) according to their spectral wavelengths and aligned in the cross-track direction. Detectors of each spectral band are aligned in the along-track direction. MODIS makes observations using a two-sided paddle-wheel scan mirror. Its on-board calibrators (OBCs) for the reflective solar bands (RSBs) include a solar diffuser (SD), a solar diffuser stability monitor (SDSM) and a spectral-radiometric calibration assembly (SRCA). Calibration is performed for each band, detector, sub-sample (for sub-kilometre resolution bands) and mirror side. In this study, a ratio approach is applied to MODIS observed Earth scene reflectances to track the detector-to-detector and mirror side differences. Simultaneous observed reflectances from the Multi-angle Imaging Spectroradiometer (MISR), also onboard the Terra spacecraft, are used with MODIS observed reflectances in this ratio approach for four closely matched spectral bands. Results show that the detector-to-detector difference between two adjacent detectors within each spectral band is typically less than 0.2% and, depending on the wavelengths, the maximum difference among all detectors varies from 0.5% to 0.8%. The mirror side differences are found to be very small for all bands except for band 3 at 0.44 μm. This is the band with the shortest wavelength among the selected matching bands, showing a time-dependent increase for the mirror side difference. This study is part of the effort by the MODIS Characterization Support Team (MCST) in order to track the RSB on-orbit performance for MODIS collection 5 data products. To support MCST efforts for future data re-processing, this analysis will be extended to include more spectral bands and temporal coverage.

28 August 2008
Verified
Conference Paper
Closed access
PDF file
AWAisheng Wu
Aisheng Wu
XXXiaoxiong Xiong
Xiaoxiong Xiong
MODIS is a key instrument on-board both EOS Terra and Aqua satellites launched in December 1999 and May 2002, respectively. It has 16 thermal emissive bands (TEB) with a wavelength range from 3.5 to 14.4μm and 10 detectors in each band. The TEB detectors are located on cold focal plane assembles nominally controlled at 83K. TEB on-orbit calibration is performed for each band, detector and mirror side on a scan-by-scan basis with the dominant gain response determined through observations of a temperature controlled on-board blackbody (BB). The noise equivalent temperature difference (NEdT) is a key parameter to characterize the calibration uncertainty. Values of the NEdT are normally monitored at a fixed BB temperature of 285K for Aqua and 290K for Terra. Variations of NEdT with BB temperature are determined using the BB warmup/cooldown cycle scheduled every three months for a BB temperature range between 270 and 315K. In this study, we extend TEB detector NEdT characterization to temperatures below the BB temperature range. This approach uses detector responses to the interior of the instrument cavity, which varies in temperature between 210 and 270K depending on the viewing portion of the cavity inner surface. This study examines the stability of the cavity inner surface responses. Comparison of the NEdT obtained from cavity and BB measurements shows good agreement at the same temperature of 270K. Finally, the results of both Terra and Aqua NEdT determined from cavity measurements are presented.

13 November 2003
Verified
Conference Paper
Closed access
PDF file
XXXiaoxiong Xiong
Xiaoxiong Xiong
KCKwo-Fu Chiang
Kwo-Fu Chiang
NCNa Chen
Na Chen
SXS. Xiong
S. Xiong
AWAisheng Wu
Aisheng Wu
WBWilliam L. Barnes
William L. Barnes
The MODerate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments for the NASA’s Earth Observing System (EOS). The MODIS ProtoFlight Model (PFM) was launched on-board the EOS Terra spacecraft on December 18, 1999. The science data acquisition started on February 24, 2000. Since then it has been providing the science community and public users unprecedented amount of data sets for the global monitoring of the Earth’s land, oceans, and atmosphere. MODIS has 36 spectral bands with wavelengths ranging from 0.41 micrometer to 14.5 micrometers. Its 16 thermal emissive bands (TEB) range from 3.7 to 14.2 micrometers and have a total of 160 individual detectors (10 detectors per band). The thermal emissive bands are calibrated on-orbit by an on-board calibrator blackbody (OBC BB) on a scan by scan basis. The detectors responses to the BB source track their operational stability and therefore their noise characteristics as well. In this paper, we provide a brief review of the MODIS TEB on-orbit calibration algorithm with a focus on detector stability using over three years of on-orbit calibration data sets. The on-orbit changes in detectors responses from one operational configuration to another, the changes within the same operational condition, and the impact of these changes on the calibration and on the Earth scene observations are carefully examined. Except for a few detectors that were identified from pre-launch or became noisy on-orbit, the overall performance of MODIS TEB detectors is very satisfactory according to the design specifications.