Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated since their launches in 1999 and 2002, respectively, and generated various data products to support the Earth remote sensing disciplines and users worldwide for their research activities and applications, including studies of the Earth system, and its changes over time and geographic regions. The MODIS data have also significantly contributed to the continuity of multi-decadal satellite data records and led to major advances in the Earth remote sensing field. The long-term data records from MODIS observations have been and will continue to be extended by the Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, currently operated aboard the Suomi-National Polar-Orbiting Partnership (NPP) and NOAA-20 satellites. The data quality of satellite instruments strongly depends on their calibration accuracy and stability. In order to help scientists and users gain a better understanding of MODIS and VIIRS data quality, this paper provides an overview of their on-orbit calibration methodologies, approaches, and results derived from instrument on-board calibrators and lunar observations, as well as select Earth view targets. What is also discussed is the calibration consistency between MODIS and VIIRS and its potential impact on producing multi-sensor long-term data records. As illustrated, the overall performance of both MODIS and VIIRS continues to meet their design requirements.
The launch of VIIRS on-board the Suomi-National Polar-orbiting Partnership (S-NPP) on 28 October 2011, marked the beginning of the next chapter on nighttime lights observation started by the Defense Meteorological Satellite Program’s (DMSP) OLS sensor more than two decades ago. The VIIRS observes the nighttime lights on Earth through its day-night band (DNB), a panchromatic channel covering the wavelengths from 500 nm to 900 nm. Compared to its predecessors, the VIIRS DNB has a much improved spatial/temporal resolution, radiometric sensitivity and, more importantly, continuous calibration using on-board calibrators (OBCs). In this paper, we describe the current state of the NASA calibration and characterization methodology used in supporting mission data quality assurance and producing consistent mission-wide sensor data records (SDRs) through NASA’s Land Product Evaluation and Analysis Tool Element (Land PEATE). The NASA calibration method utilizes the OBCs to determine gains, offset drift and sign-to-noise ratio (SNR) over the entire mission. In gain determination, the time-dependent relative spectral response (RSR) is used to correct the optical throughput change over time. A deep space view acquired during an S-NPP pitch maneuver is used to compute the airglow free dark offset for DNB’s high gain stage. The DNB stray light is estimated each month from new-moon dark Earth surface observations to remove the excessive stray light over the day-night terminators. As the VIIRS DNB on-orbit calibration is the first of its kind, the evolution of the calibration methodology is evident when the S-NPP VIIRS’s official calibrations are compared with our latest mission-wide reprocessing. In the future, the DNB calibration methodology is likely to continue evolving, and the mission-wide reprocessing is a key to providing consistently calibrated DNB SDRs for the user community. In the meantime, the NASA Land PEATE provides an alternative source to obtain mission-wide DNB SDR products that are calibrated based on the latest NASA DNB calibration methodology.
The MODerate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with wavelengths from 0.41 to 14.5 micrometers. The 36 spectral bands, with a total of 490 detectors, are distributed on four focal plane assemblies (FPAs): visible (VIS), near infrared (NIR), short- mid-wave infrared (SMIR), and long wave infrared (LWIR). Nearly identical copies of the MODIS are currently operating onboard the NASA EOS Terra (launched on December 18,1999) and Aqua spacecraft (launched on May 4, 2002). Prelaunch and on-orbit characterizations of both Terra and Aqua MODIS have shown small but non-negligible out-of-band (OOB) response in the sensor's short-wave infrared bands (SWIR): bands 5-7, and band 26. To minimize the impact due to OOB response on the MODIS SWIR bands calibration and the Earth scene product retrieval, an algorithm has been developed and implemented in the Level 1B (L1B) software for both Terra and Aqua MODIS. In this paper, we describe the algorithm and its applications to the MODIS L1B calibration algorithms. We illustrate how the correction coefficients are derived from on-orbit observations and discuss the test procedures involved before the final implementation in the L1B code. Performance is evaluated for both Terra and Aqua MODIS and the two results are compared.
The MODerate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments for the NASA’s Earth Observing System (EOS). The MODIS ProtoFlight Model (PFM) was launched on-board the EOS Terra spacecraft on December 18, 1999. The science data acquisition started on February 24, 2000. Since then it has been providing the science community and public users unprecedented amount of data sets for the global monitoring of the Earth’s land, oceans, and atmosphere. MODIS has 36 spectral bands with wavelengths ranging from 0.41 micrometer to 14.5 micrometers. Its 16 thermal emissive bands (TEB) range from 3.7 to 14.2 micrometers and have a total of 160 individual detectors (10 detectors per band). The thermal emissive bands are calibrated on-orbit by an on-board calibrator blackbody (OBC BB) on a scan by scan basis. The detectors responses to the BB source track their operational stability and therefore their noise characteristics as well. In this paper, we provide a brief review of the MODIS TEB on-orbit calibration algorithm with a focus on detector stability using over three years of on-orbit calibration data sets. The on-orbit changes in detectors responses from one operational configuration to another, the changes within the same operational condition, and the impact of these changes on the calibration and on the Earth scene observations are carefully examined. Except for a few detectors that were identified from pre-launch or became noisy on-orbit, the overall performance of MODIS TEB detectors is very satisfactory according to the design specifications.
The Visible Infrared Imaging Radiometer Suite (VIIRS) is a radiometric sensing instrument currently operating onboard the Suomi National Polar-orbiting Partnership (S-NPP) spacecraft. It provides high spatial-resolution images of the emitted and reflected radiation from the Earth and its atmosphere in 22 spectral bands (16 moderate resolution bands M1-M16, 5 imaging bands I1-I5, and 1 day/night pan band DNB) spanning the visible and infrared wavelengths from 412 nm to 12 μm. Just prior to each scan it makes of the Earth, the VIIRS instrument makes a measurement of deep space to serve as a background reference. These space view (SV) measurements form a crucial input to the VIIRS calibration process and are a major determinant of its accuracy. On occasion, the orientation of the Suomi NPP spacecraft coincides with the position of the moon in such a fashion that the SV measurements include light from the moon, rendering the SV measurements unusable for calibration. This paper investigates improvements to the existing baseline SV data processing algorithm of the Sensor Data Record (SDR) processing software. The proposed method makes use of a Moon-in-SV detection algorithm that identifies moon-contaminated SV data on a scan-by-scan basis. Use of this algorithm minimizes the number of SV scans that are rejected initially, so that subsequent substitution processes are always able to find alternative substitute SV scans in the near vicinity of detected moon-contaminated scans.