Andreas Napp

Andreas Napp

Auto-generated profile, based on publicly available information

Andreas Napp

Department of Cardiology, Angiology and Critical Care (Medical Clinic 1), University Hospital RWTH, Aachen, Germany

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2015 in European Heart Journal
Verified
Journal Article
Closed access
PDF file
ANAndreas Napp
Andreas Napp
DSDominik Stunder
Dominik Stunder
MMMelanie Maytin
Melanie Maytin
TKThomas Kraus
Thomas Kraus
NMNikolaus Marx
Nikolaus Marx
SDSarah Driessen
Sarah Driessen
Utilization of cardiac implants such as pacemakers and implantable cardioverter defibrillators is now commonplace among heart disease patients. The ever-increasing technological complexity of these devices is matched by the near omnipresent exposure to electric, magnetic, and electromagnetic fields (EMFs), both in everyday life and the occupational environment. Given that electromagnetic interferences (EMIs) are associated with potential risk in device patients, physicians are increasingly confronted with managing device patients with intermittent EMI and chronic occupational exposure. The current review aims to provide a contemporary overview of cardiovascular implantable electronic devices, their function and susceptibility of non-medical EMFs and provide recommendations for physicians caring for cardiac device patients presenting with EMI.

13 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MZMatthias Daniel Zink
Matthias Daniel Zink
CBChristoph Brüser
Christoph Brüser
BSBjörn-Ole Stüben
Björn-Ole Stüben
ANAndreas Napp
Andreas Napp
RSRobert Stöhr
Robert Stöhr
JSJohannes Schiefer
Johannes Schiefer
Sleep disordered breathing (SDB) is known for fluctuating heart rates and an increased risk of developing arrhythmias. The current reference for heartbeat analysis is an electrocardiogram (ECG). As an unobtrusive alternative, we tested a sensor foil for mechanical vibrations to perform a ballistocardiography (BCG) and applied a novel algorithm for beat-to-beat cycle length detection. The aim of this study was to assess the correlation between beat-to-beat cycle length detection by the BCG algorithm and simultaneously recorded ECG. In 21 patients suspected for SDB undergoing polysomnography, we compared ECG to simultaneously recorded BCG data analysed by our algorithm. We analysed 362.040 heartbeats during a total of 93 hours of recording. The baseline beat-to-beat cycle length correlation between BCG and ECG was r s = 0.77 (n = 362040) with a mean absolute difference of 15 ± 162 ms (mean cycle length: ECG 923 ± 220 ms; BCG 908 ± 203 ms). After filtering artefacts and improving signal quality by our algorithm, the correlation increased to r s = 0.95 (n = 235367) with a mean absolute difference in cycle length of 4 ± 72 ms (ECG 920 ± 196 ms; BCG 916 ± 194 ms). We conclude that our algorithm, coupled with a BCG sensor foil provides good correlation of beat-to-beat cycle length detection with simultaneously recorded ECG.

27 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MZMatthias Daniel Zink
Matthias Daniel Zink
FKFabienne König
Fabienne König
SWSören Weyer
Sören Weyer
KWKlaus Willmes
Klaus Willmes
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
ANAndreas Napp
Andreas Napp
Bioelectrical impedance spectroscopy (BIS) measures body composition, including fluid status. Acute decompensated heart failure (ADHF) is associated with fluid overload in different body compartments. This investigation aimed to evaluate the feasibility of measuring and monitoring fluid accumulation in patients with ADHF using BIS. The extracellular impedance as a surrogate marker for fluid accumulation was measured in 67 participants (25 healthy reference volunteers and 42 patients admitted with ADHF) using BIS in the “transthoracic”, “foot-to-foot”, “whole-body” and “hand-to-hand” segments. At baseline, BIS showed significantly lower extracellular resistance values for the “whole-body” (P < 0.001), “foot-to-foot” (P = 0.03), “hand-to-hand” (P < 0.001) and “transthoracic” (P = 0.014) segments in patients with ADHF than the reference cohort, revealing a specific pattern for peripheral, central and general fluid accumulation. The “foot-to-foot” (AUC = 0.8, P < 0.001) and “hand-to-hand” (AUC = 0.74, P = 0.04) segments indicated compartments of fluid accumulation with good prediction. During cardiac recompensation, BIS values changed significantly and were in line with routine parameters for monitoring ADHF. Mean bodyweight change per day correlated moderately to good with BIS values in the “whole-body” (r = −0.4), “foot-to-foot” (r = −0.8) and “transthoracic” (r = −0.4) segments. Based on our analysis, we conclude that measuring and monitoring fluid accumulation in ADHF using segmental BIS is feasible and correlates with clinical parameters during recompensation.

4 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DUDurmus Umutcan Uguz
Durmus Umutcan Uguz
RDRosalia Dettori
Rosalia Dettori
ANAndreas Napp
Andreas Napp
MWMarian Walter
Marian Walter
NMNikolaus Marx
Nikolaus Marx
Christoph Hoog AntinkChristoph Hoog Antink
Christoph Hoog Antink
The capacitive electrocardiograph (cECG) has been tested for several measurement scenarios, including hospital beds, car seats and chairs since it was first proposed. The inferior signal quality of the cECG compared to the gold standard ECG guides the ongoing research in the direction of out-of-hospital applications, where unobtrusiveness is sought and high-level diagnostic signal quality is not essential. This study aims to expand the application range of cECG not in terms of the measurement scenario but in the profile of the subjects by including subjects with implanted cardiac pacemakers. Within this study, 20 patients with cardiac pacemakers were recruited during their clinical device follow-up and cECG measurements were conducted using a seat equipped with integrated cECG electrodes. The multichannel cECG recordings of active unipolar and bipolar pacemaker stimulation were analyzed offline and evaluated in terms of Fβ scores using a pacemaker spike detection algorithm. Fβ scores from 3652 pacing events, varying from 0.62 to 0.78, are presented with influencing parameters in the algorithm and the comparison of cECG channels. By tuning the parameters of the algorithm, different ranges of Fβ scores were found as 0.32 to 0.49 and 0.78 to 0.88 for bipolar and unipolar stimulations, respectively. For the first time, this study shows the feasibility of a cECG system allowing health monitoring in daily use on subjects wearing cardiac pacemakers.

28 February 2017 in Circulation
Verified
Journal Article
Closed access
PDF file
DSDominik Stunder
Dominik Stunder
TSTobias Seckler
Tobias Seckler
SJStephan Joosten
Stephan Joosten
MZMatthias Daniel Zink
Matthias Daniel Zink
SDSarah Driessen
Sarah Driessen
ANAndreas Napp
Andreas Napp

26 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Malte JacobsenMalte Jacobsen
Malte Jacobsen
Till A. DembekTill A. Dembek
Till A. Dembek
AZAthanasios-Panagiotis Ziakos
Athanasios-Panagiotis Ziakos
rahil gholamipoorrahil gholamipoor
rahil gholamipoor
GKGuido Kobbe
Guido Kobbe
MSMelchior Seyfarth
Melchior Seyfarth
Atrial fibrillation (AF) is the most common arrhythmia and has a major impact on morbidity and mortality; however, detection of asymptomatic AF is challenging. This study aims to evaluate the sensitivity and specificity of non-invasive AF detection by a medical wearable. In this observational trial, patients with AF admitted to a hospital carried the wearable and an ECG Holter (control) in parallel over a period of 24 h, while not in a physically restricted condition. The wearable with a tight-fit upper armband employs a photoplethysmography technology to determine pulse rates and inter-beat intervals. Different algorithms (including a deep neural network) were applied to five-minute periods photoplethysmography datasets for the detection of AF. A total of 2306 h of parallel recording time could be obtained in 102 patients; 1781 h (77.2%) were automatically interpretable by an algorithm. Sensitivity to detect AF was 95.2% and specificity 92.5% (area under the receiver operating characteristics curve (AUC) 0.97). Usage of deep neural network improved the sensitivity of AF detection by 0.8% (96.0%) and specificity by 6.5% (99.0%) (AUC 0.98). Detection of AF by means of a wearable is feasible in hospitalized but physically active patients. Employing a deep neural network enables reliable and continuous monitoring of AF.