1 June 2022 in Molecular Imaging and Radionuclide Therapy
This study aimed to evaluate the ability of 18fluorine-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) radiomic features combined with machine learning methods to distinguish between benign and malignant solitary pulmonary nodules (SPN). Data of 48 patients with SPN detected on 18F-FDG PET/CT scan were evaluated retrospectively. The texture feature extraction from PET/CT images was performed using an open-source application (LIFEx). Deep learning and classical machine learning algorithms were used to build the models. Final diagnosis was confirmed by pathology and follow-up was accepted as the reference. The performances of the models were assessed by the following metrics: Sensitivity, specificity, accuracy, and area under the receiver operator characteristic curve (AUC). The predictive models provided reasonable performance for the differential diagnosis of SPNs (AUCs ~0.81). The accuracy and AUC of the radiomic models were similar to the visual interpretation. However, when compared to the conventional evaluation, the sensitivity of the deep learning model (88% vs. 83%) and specificity of the classic learning model were higher (86% vs. 79%). Machine learning based on 18F-FDG PET/CT texture features can contribute to the conventional evaluation to distinguish between benign and malignant lung nodules.
30 December 2022 in Medicine
ITIlhan Asistant Tasdoven
HBHakan Asistant Balbaloglu
Hakan Asistant Balbaloglu
CKCakmak Guldeniz Karadeniz
Cakmak Guldeniz Karadeniz
Axillary staging is 1 of the major issues of current breast cancer management after neoadjuvant systemic therapy (NST). Sentinel lymph node biopsy (SLNB) is an option for clinically node negative patients. Axillary reverse mapping (ARM) was introduced to identify and preserve the lymphatic drainage from the arm. The aim of the presented study is to employ triple mapping (radiocolloid, blue dye and indocyanine green [ICG]) to assess the crossover rate and metastatic involvement of ARM nodes after NST. Clinically node positive patients before NST who were converted to N0 and scheduled for targeted axillary dissection were included. sentinel lymph node (SLN) mapping was performed via dual agent mapping. ICG was used for ARM procedure. Blue, hot and fluorescent nodes and lymphatics were visualized in the axilla using infrared camera system and dual opto-nuclear probe (Euoroprobe3). Fifty-two patients underwent targeted axillary dissection and ARM procedures 12 out of whom had axillary node dissection. 45 of the 52 patients had at least 1 hot or blue SLN identified intraoperatively. Of these, 61.5% cases had hot SLNs, 42.3% had hot and blue, 15.4% had hot/blue/fluorescent, 7.7% had blue/fluorescent, 6 11.5% had hot/fluorescent and 7 13.5% had only clipped nodes. The overall identification rate of ARM-nodes by means of ICG technique was 86.5%. Overall crossover of ARM nodes with SLNs was determined in 36.5%. The ICG intensity was found to be higher in both hot and blue SLNS (8 out of 18 ICG positive cases, 44.4%). In 3 of 52 patients (5.7%) metastatic SLNs were hot or blue but fluorescent which predicts metastatic involvement of the ARM-nodes. More than 1-third of the patients revealed a crossover between arm and breast draining nodes. The higher observed rate of overlap might partially explain why more patients develop clinically significant lymphedema after NST even after sentinel lymph node biopsy alone. The triple mapping provides valuable data regarding the competency of lymphatic drainage and would have the potential to serve selecting patients for lymphovenous by-pass procedures at the index procedure. NST reduces the metastatic involvement of the ARM nodes. However, conservative axillary staging with sparing ARM nodes after NST necessitates further studies with larger sample size and longer follow-up.
21 October 2021 in TURKISH JOURNAL OF MEDICAL SCIENCES
This study aimed to evaluate the effect of sono-scintigraphic correlation on the success of minimal invasive parathyroidectomy (MIP) via surgeon performed continuous intraoperative sonographic guidance in patients operated for primary hyperparathyroidism(PHPT) without intact parathormone (PTH) measurement. A retrospective analysis of a prospective database was conducted to review patients who underwent MIP (July 2017-October 2019). The screened parameters were preoperative PTH level, preoperative ultrasonography (US), preoperative scintigraphy, intraoperative US, intraoperative frozen section analysis, postoperative PTH level and permanent pathology report. Intraoperative intact PTH measurement was not employed due to institutional policy. Preoperative US alone localized the specific side (right/left, inferior/superior) of abnormality in 54 out of 74 (72.97%) cases. Scintigraphy alone localized the specific side in 58 (78.37%) cases. The sensitivity of preoperative US and scintigraphy alone was 76.05% and 86.56%, respectively. Sono-scintigraphic discordance was present in 6 cases (8.1%) and intraoperative real-time US predicted accurate localization of adenoma in 4 (66.6%) and scintigraphy in 2 (44.4%) patients. The frozen section analysis confirmed parathyroid cells in all cases evaluated. Sono-scintigraphic concordance with intraoperative real-time imaging increases surgical success rates in cases where MIP is planned under the circumstances of limited resources regarding unavailability of intact PTH measurement.
27 October 2023 in Medicine
There has been an increase in positron emission tomography (PET)/computed tomography (CT) imaging procedures, and medical workers involved in PET/CT are at increased risk of occupational exposure. Data on extremity dose exposure are limited globally. The current study aimed to evaluate the occupational radiation dose for extremities for medical workers (nurses, radiographers/radiologic technologists, and nuclear medicine physicians) working in PET/CT scanners at 5 large hospitals in Turkey. Optically stimulated luminescence (OSL) and Thermoluminescent dosimeter (TLD) ring dosimeters were used to measure equivalent dose values. Hospitals 1, 2, and 5 used OSL, and 3 and 4 used TLD. A total of 502 readings were obtained from 55 workers. In millisievert (mSv), the average annual effective dose for all workers was 14.5 ± 17.7 (0.2–157.2). A radiography technologist received a maximum dose of 157.21. Nurses received the highest average annual effective dose (15.2 ± 19.46) (0.32–65.58), followed by radiography technologists (14.7 ± 18.03) (0.4–157.2), and nuclear medicine physicians demonstrated the least dose (8.6 ± 10.5) (1.2–24.4). The results show that the extremity dose is well below the annual dose limit of 500 mSv. However, there is a wide variation in dose among the workers, underlining a need for careful assessment of working conditions to ensure safe practices for all workers.
27 December 2022 in Batı Karadeniz Tıp Dergisi
Amaç: Pozitron-emisyon-tomografisi/ bilgisayarlı tomografi (PET/BT) bir nükleer tıp görüntüleme yöntemidir ve yaygın olarak onkolojide kullanılır. PET/BT görüntüleme yönteminde kullanılan F(flor)-18 radyoizotopu konvansiyonel nükleer tıpta kullanılan diğer radyoizotoplara göre daha yüksek foton enerjisine sahiptir. Çalışmamızda F-18 fluorodeoksiglukoz (FDG) ile PET/BT çekimi yapılan hastaların taburculuk sırasında çevreye salınan radyasyonun doz hızının ölçülmesi ve çevresel radyasyon maruziyetinin değerlendirilmesi amaçlanmıştır. Yöntem: Çalışmamıza, Zonguldak Bülent Ecevit Üniversitesi Nükleer Tıp PET/BT ünitesine başvuran toplam 353 (E/K=177/176) hasta dahil edilmiştir. Hastalara F-18 FDG ile PET/BT çekimi yapıldıktan sonra taburcu edilmeden önce 0.5 metre (m), 1 m ve 2 m mesafeden toraks düzeyinden Geiger-Müller probu kullanılarak doz hızı ölçümleri yapılmış ve kayıt altına alınmıştır. Ölçümler arasında istatistiksel olarak anlamlı farklılık olup olmadığı değerlendirilmiştir. Bulgular: Hastalara IV yol ile 331±149 megabecquerel (MBq) (Aralık: 182-481) radyoaktif madde enjekte edilmiş ve PET/BT ünitesinde enjeksiyon sonrası 104,5±34,5 dk (Aralık: 70 -139) beklemiştir. Taburculuk sırasında 0,5 m, 1 m ve 2 m m mesafelerden alınan radyasyon doz hızı ölçümleri, sırasıyla 33,20±20,50 mikrosievert/saat (µSv/sa), 15,94±10,55 µSv/sa ve 6,56 ±4,43 µSv/sa olarak hesaplanmıştır. Sonuç: F-18 FDG PET/ BT çekimi sonrası taburculuk sırasında hastaların 0.5,1 ve 2 m mesafelerdeki doz hızı ölçümlerinin, uluslararası ve ulusal radyasyon düzenleme kuralları göz önünde bulundurulduğunda, çevresel radyasyon güvenliği açısından bir tehlike arz etmediği gösterilmiştir. F-18 FDG enjeksiyonundan yaklaşık iki saat sonra hastayla temas edenler için ciddi radyasyon riski bulunmamakta olup güvenli bir şekilde taburcu edilebilmektedir.
1 January 2021 in Chirurgia