New energy, transport, computer and telecommunication technologies require an increasing supply of rare earth elements (REEs). As a consequence, adequate and robust detection methods become essential for the exploration and discovery of new deposits, the improved characterization of existing deposits and the future recycling of today’s high-tech products. Within this paper, we investigate the potential of combining passive reflectance (imaging and point sampling) with laser stimulated luminescence (point sampling) spectroscopic measurements across the visible, near and shortwave infrared for REE detection in non-invasive near-field mineral exploration. We analyse natural REE-bearing mineral samples from main REE-deposits around the world and focus on challenges such as the discrimination of overlapping spectroscopic features and the influence of the mineral type on detectability, feature position and mineral matrix luminescence. We demonstrate that the cross-validation of results from both methods increases the robustness and sensitivity, provides the potential for semi-quantification and enables the time- and cost-efficient detection of economically important REE, including Ce, Pr, Nd, Sm, Eu, Dy, Er, Yb and potentially also Ho and Tm.
In recent times, rare earth orthophosphates ( PO ) have shown great potential as efficient optical materials. They possess either or –type structures. These light or heavy rare earth bearing orthophosphates also exhibit an extraordinary stability over geological time scale in nature, ∼10 years. In the present contribution, we measure, collect, and present a library of absorption spectra of all the PO hosts ( = La–Lu, except Pm) using their single crystal samples, to conclude that the observed spectral features for wavelengths longer than 200 nm were attributable to either Ln- or defect related centers, which corroborate the fact that they have a bandgap higher than 8.0 eV. The absorption band around wavelength, 275 nm, corresponds to defect absorption related to PO centers and/or oxygen vacancies. The hosts can potentially be used to study and interpret unperturbed rare earth emissions due to absence of host related absorption above 300 nm. The information presented herein is expected to serve as a library of absorption spectra for geologists, physicists, material scientists, and chemists working in the field of rare earths.
The capacitance behavior of metal insulator metal (MIM) structures with dielectrics and TiN metal electrodes is analyzed. The capacitance nonlinearity, the dielectric relaxation, and the loss phenomena are found to depend strongly on the Al content, the dielectric thickness, and the amorphous/crystalline phase of the dielectric layer. Two different kinds of phenomena—crystallization-related and interface-related, are considered to explain the observed results, especially the polarity asymmetry in the dielectric behavior. It is found that crystallization of the films enhances the effects of dielectric relaxation and loss, most likely due to charge trapping at grain boundaries. Further on, reactions between the oxidizing ambient (ozone) and the bottom electrode during high- deposition result in structural changes (formation of interfacial layer) and thus in generation of defects which cause a different electrical behavior of the two interfaces at the top and the bottom electrode and a polarity asymmetry of the capacitance performance.
Polymers represent around 25% of total waste from electronic and electric equipment. Any successful recycling process must ensure that polymer-specific functionalities are preserved, to avoid downcycling. This requires a precise characterization of particle compounds moving at high speeds on conveyor belts in processing plants. We present an investigation using imaging and point measurement spectral sensors on 23 polymers including ABS, PS, PC, PE-types, PP, PVC, PET-types, PMMA, and PTFE to assess their potential to perform under the operational conditions found in recycling facilities. The techniques applied include hyperspectral imaging sensors (HSI) to map reflectance in the visible to near infrared (VNIR), short-wave (SWIR) and mid-wave infrared (MWIR) as well as point Raman, FTIR and spectroradiometer instruments. We show that none of the sensors alone can identify all the compounds while meeting the industry operational requirements. HSI sensors successfully acquired simultaneous spatial and spectral information for certain polymer types. HSI, particularly the range between (1600-1900) nm, is suitable for specific identification of transparent and light-coloured (non-black) PC, PE-types, PP, PVC and PET-types plastics; HSI in the MWIR is able to resolve specific spectral features for certain PE-types, including black HDPE, and light-coloured ABS. Fast-acquisition Raman spectroscopy (down to 500 ms) enabled the identification of all polymers regardless their composition and presence of black pigments, however, it exhibited limited capacities in mapping applications. We therefore suggest a combination of both imaging and point measurements in a sequential design for enhanced robustness on industrial polymer identification.
Due to the rapidly increasing use of energy-efficient technologies, the need for complex materials containing rare earth elements (REEs) is steadily growing. The high demand for REEs requires the exploration of new mineral deposits of these valuable elements, as recovery by recycling is still very low. Easy-to-deploy sensor technologies featuring high sensitivity to REEs are required to overcome limitations by traditional techniques, such as X-ray fluorescence. We demonstrate the ability of laser-induced fluorescence (LIF) to detect REEs rapidly in relevant geological samples. We introduce two-dimensional LIF mapping to scan rock samples from two Namibian REE deposits and cross-validate the obtained results by employing mineral liberation analysis (MLA) and hyperspectral imaging (HSI). Technique-specific parameters, such as acquisition speed, spatial resolution, and detection limits, are discussed and compared to established analysis methods. We also focus on the attribution of REE occurrences to mineralogical features, which may be helpful for the further geological interpretation of a deposit. This study sets the basis for the development of a combined mapping sensor for HSI and 2D LIF measurements, which could be used for drill-core logging in REE exploration, as well as in recovery plants.
Ge-rich ZrO2 films, fabricated by confocal RF magnetron sputtering of pure Ge and ZrO2 targets in Ar plasma, were studied by multi-angle laser ellipsometry, Raman scattering, Auger electron spectroscopy, Fourier transform infrared spectroscopy, and X-ray diffraction for varied deposition conditions and annealing treatments. It was found that as-deposited films are homogeneous for all Ge contents, thermal treatment stimulated a phase separation and a formation of crystalline Ge and ZrO2. The “start point” of this process is in the range of 640–700 °C depending on the Ge content. The higher the Ge content, the lower is the temperature necessary for phase separation, nucleation of Ge nanoclusters, and crystallization. Along with this, the crystallization temperature of the tetragonal ZrO2 exceeds that of the Ge phase, which results in the formation of Ge crystallites in an amorphous ZrO2 matrix. The mechanism of phase separation is discussed in detail.