Clarice Dias Britto Amaral

Clarice Dias Britto Amaral

Auto-generated profile, based on publicly available information

Clarice Dias Britto Amaral

Department of Chemistry, Federal University of Paraná, Curitiba, Brazil

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
ASAna P.R. Santana
Ana P.R. Santana
JMJorge A. Mora-Vargas
Jorge A. Mora-Vargas
TGTaciana G.S. Guimarães
Taciana G.S. Guimarães
CAClarice D.B. Amaral
Clarice D.B. Amaral
AOAndréa Cheble de Oliveira
Andréa Cheble de Oliveira
MGMARIO HENRIQUE GONZALEZ
MARIO HENRIQUE GONZALEZ

1 July 2019 in Talanta
Verified
Journal Article
Closed access
ASAna P.R. Santana
Ana P.R. Santana
DADaniel F. Andrade
Daniel F. Andrade
JMJorge A. Mora-Vargas
Jorge A. Mora-Vargas
CAClarice D.B. Amaral
Clarice D.B. Amaral
AOAndréa Cheble de Oliveira
Andréa Cheble de Oliveira
MGMARIO HENRIQUE GONZALEZ
MARIO HENRIQUE GONZALEZ

1 January 2017 in Microchemical Journal
Verified
Journal Article
Closed access
RMRaquel C. Machado
Raquel C. Machado
CAClarice D.B. Amaral
Clarice D.B. Amaral
DSDaniela Schiavo
Daniela Schiavo
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
ANAna Rita Nogueira
Ana Rita Nogueira

17 April 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
RARenata S. Amais
Renata S. Amais
CAClarice D. B. Amaral
Clarice D. B. Amaral
LFLucimar L. Fialho
Lucimar L. Fialho
DSDaniela Schiavo
Daniela Schiavo
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
The feasibility of inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) to overcome polyatomic interferents in severely affected isotope determination is demonstrated here. This instrument arrangement presents an octopole reaction/collision system (ORS) in between two quadrupole mass analyzers. The first quadrupole operates as a mass filter which allows just the target mass-to-charge ratio (m/z) to enter the ORS and rejects all other species with m/z different from the target analyte's m/z. Once in the ORS, analytes react with the reaction gas introduced into the ORS, and the second quadrupole selects the product of the reaction's m/z (mass shift operation mode). We describe here a procedure for accurate determination of P, S and Si in biodiesel, diesel and lubricating oil by ICP-MS/MS. Fuel standard reference materials (SRMs) were microwave-assisted acid-digested using nitric acid and hydrogen peroxide. The oxygen gas flow rate in the ORS was optimized considering the limit of detection (LOD) values and accuracies reached for P, S and Si determinations in the lubricating oil SRM and the best oxygen gas flow rate was 0.75 mL min−1. Adopting optimized conditions, limits of detection were 1.2, 0.49, 0.31, 0.33 and 0.78 μg L−1 for 28Si16O+, 29Si16O+, 31P16O+, 32S16O+ and 34S16O+, respectively. Adequate precision, accuracy and sensitivity were obtained when using the mass shift mode and recoveries for biodiesel, diesel and lubricating oil digests ranged from 95.0 to 113%. No significant differences were observed between the certified values and the ones obtained using ICP-MS/MS at a 95% confidence level.

1 October 2013 in Talanta
Verified
Journal Article
Closed access
CAClarice D.B. Amaral
Clarice D.B. Amaral
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
ANAna Rita Nogueira
Ana Rita Nogueira

15 December 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
CAClarice D. B. Amaral
Clarice D. B. Amaral
RARenata S. Amais
Renata S. Amais
LFLucimar L. Fialho
Lucimar L. Fialho
DSDaniela Schiavo
Daniela Schiavo
TATatiane Amorim
Tatiane Amorim
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
This work demonstrates the potential of inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) in trace element analysis. Aiming Hg determination in water, sample preservation requires chloride addition, which presents formation of polyatomic interfering ions as a drawback for the determination of other analytes (e.g. As and V). Thus, the effect of chloride on As, Cr, V and Hg determination and the feasibility of using ICP-MS/MS to circumvent the interference were evaluated. A standard reference material (NIST SRM 1643e) and recoveries from tap water spiked with As, Cr, Hg and V were used for accuracy assessment and for the evaluation of matrix effects. The reaction between Hg and oxygen gas is not favorable in the octopole reaction system (ORS3). Therefore, Hg was accurately determined as a single atom ion (202Hg+) under the same analytical conditions adopted for As, Cr and V determination by monitoring 75As16O+, 52Cr16O+ and 51V16O+ while the ORS3 was pressurized with oxygen gas. The oxygen reaction mode significantly improved the accuracy for As, Cr and V, especially at the lowest spiked level, which is strongly affected by matrix effects. The signal gain in m/z 75 for a solution containing 1 μg L−1 As in 0.48 mol L −1 chloride medium was 1974% when employing single quadrupole mode. On the other hand, the signal increased only 7% when 0.75 mL min−1 O2 was used in mass shift mode proving the efficiency of the MS/MS mode. Thus, ICP-MS/MS and ORS3 pressurized with O2 gas effectively reduced the interference, and enhanced the accuracy and sensitivity for some specific isotopes in a complex medium. The limits of detection for V (51V16O+), Cr (52Cr16O+), As (75As16O+) and Hg (202Hg+) were estimated to be 2, 3, 1.6 and 38 ng L−1 at the 99.7% confidence level, respectively.