Tobias Reum

Tobias Reum

Auto-generated profile, based on publicly available information

Tobias Reum

Technische Hochschule Ingolstadt

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2024 in International Journal of Refrigeration
Verified
Journal Article
Open access
TRTobias Reum
Tobias Reum
DSDavid Schmitt
David Schmitt
TSThorsten Summ
Thorsten Summ
CTChristoph Trinkl
Christoph Trinkl
FOFabian Ochs
Fabian Ochs
TSTobias Schrag
Tobias Schrag

22 April 2024 in International Sustainable Energy Conference - Proceedings
Verified
Journal Article
Open access
PDF file
DSDavid Schmitt
David Schmitt
TRTobias Reum
Tobias Reum
TSThorsten Summ
Thorsten Summ
CTChristoph Trinkl
Christoph Trinkl
TSTobias Schrag
Tobias Schrag
Using the thermal building mass as a thermal storage received increasing attention in research during recent years. Due to the large mass of concrete, it offers a large storage capacity and thus a high potential for flexibility. However, passive heat losses during cool down of a thermally activated building influence room temperature and thus limit its flexibility potential. In this contribution a multi-layer activation concept was investigated which thermally decouples the building mass and room air. The study aims to analyse the cool down of a thermally activated building in terms of different charging parameters while considering other heat sources such as solar gains. A dynamic building simulation of a demonstration building was set-up and compared to simulative studies from literature to proof the validity of its dynamic behaviour. In the simulation model the room temperature could be kept above 19 °C between 100 - 190 h. However, when charging the building structure quickly, room temperatures above 24 °C are reached easily. Considering other heat sources such as solar gains, advanced control algorithms are required for efficient operation of the heating system.

23 November 2025
Verified
Book Chapter
Closed access
PDF file
TRTobias Reum
Tobias Reum
CNChristian Natale
Christian Natale
DSDavid Schmitt
David Schmitt
MDMatteo Dongellini
Matteo Dongellini
CNClaudia Naldi
Claudia Naldi
TSTobias Schrag
Tobias Schrag


24 April 2024 in International Sustainable Energy Conference - Proceedings
Verified
Journal Article
Open access
PDF file
TRTobias Reum
Tobias Reum
DSDavid Schmitt
David Schmitt
TSThorsten Summ
Thorsten Summ
TSTobias Schrag
Tobias Schrag
Dual-source heat pumps can mitigate disadvantages of single source heat pumps: They have fewer geological requirements compared to ground-source heat pumps while having higher efficiencies compared to air-source heat pumps. Parallel operation of two heat sources can also make electric heaters for peak loads obsolete, leading to economic benefits in the operational costs. Parallel operation has not been analysed thoroughly at different evaporation temperature gradients. To address this gap in research, four possible interconnections of two heat sources were analysed using a refrigerant cycle simulation, two with similar and two with separate evaporation pressures. The energetic potential of each interconnection is evaluated and compared to single source operation with an air-source and a ground-source heat pump. The results showed that only the interconnections with separate evaporation pressure allowed significant reduction in evaporation power from the ground source. As expected, the efficiency – compared to single air-source operation – increased for all parallel interconnections but decreased compared to ground-source operation. Efficient peak load coverage with small ground-source collectors therefore requires a more complex interconnection of completely split evaporator branches at different evaporation pressures. While the efficiency and heating power compared to single ground-source operation decreased slightly (by 4% and 6%, respectively), the power load on the GSHX and ASHX reduced to about 54% and 66% compared to the corresponding single-source operation, respectively. This allows high efficiency at reduced GSHX size and ASHX noise emission. Additionally, this interconnection also allows increased flexibility for improved heat source management.