Department of Anesthesiology and Intensive Care Medicine (CCM, CVK); Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
Auto-generated profile, based on publicly available information
Thilo Busch
Department of Anesthesiology and Intensive Care Medicine (CCM, CVK); Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
The contribution of veno-venous (VV) extracorporeal membrane oxygenation (ECMO) to systemic oxygen delivery is determined by the ratio of total extracorporeal blood flow ( ) to cardiac output ( ). Thermodilution-based measurements of may be compromised by blood recirculating through the ECMO (recirculation fraction; Rf). We measured the effects of and Rf on classic thermodilution-based measurements of in six anesthetized pigs. An ultrasound flow probe measured total aortic blood flow ( ) at the aortic root. Rf was quantified with the ultrasound dilution technique. was set to 0–125% of and was measured using a pulmonary artery catheter (PAC) in healthy and lung injured animals. PAC overestimated ( ) at all settings compared to . The mean bias between both methods was 2.1 L/min in healthy animals and 2.7 L/min after lung injury. The difference between and increased with an of 75–125%/ compared to QEC <50%/ . Overestimation of was highest when resulted in a high Rf. Thus, thermodilution-based measurements can overestimate cardiac output during VV ECMO. The degree of overestimation of depends on the EC/ ratio and the recirculation fraction.
1 June 2008 in Respiratory Physiology & Neurobiology
Purpose: Admixture of nitric oxide (NO) to the gas inspired with mechanical ventilation can be achieved through continuous, timed, or pulsed injection of NO into the inspiratory limb. The dose and timing of NO injection govern the inspired and intrapulmonary effect site concentrations achieved with different administration modes. Here we test the effectiveness and target reliability of a new mode injecting pulsed NO boluses exclusively during early inspiration. Methods: An in vitro lung model was operated under various ventilator settings. Admixture of NO through injection into the inspiratory limb was timed either (i) selectively during early inspiration (“pulsed delivery”), or as customary, (ii) during inspiratory time or (iii) the entire respiratory cycle. Set NO target concentrations of 5–40 parts per million (ppm) were tested for agreement with the yield NO concentrations measured at various sites in the inspiratory limb, to assess the effectiveness of these NO administration modes. Results: Pulsed delivery produced inspiratory NO concentrations comparable with those of customary modes of NO administration. At low (450 ml) and ultra-low (230 ml) tidal volumes, pulsed delivery yielded better agreement of the set target (up to 40 ppm) and inspiratory NO concentrations as compared to customary modes. Pulsed delivery with NO injection close to the artificial lung yielded higher intrapulmonary NO concentrations than with NO injection close to the ventilator. The maximum inspiratory NO concentration observed in the trachea (68 ± 30 ppm) occurred with pulsed delivery at a set target of 40 ppm. Conclusion: Pulsed early inspiratory phase NO injection is as effective as continuous or non-selective admixture of NO to inspired gas and may confer improved target reliability, especially at low, lung protective tidal volumes.