Anyu Jiang

Anyu Jiang

Auto-generated profile, based on publicly available information

Anyu Jiang

University of Florida

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2025 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Asif Iftekhar OmiAsif Iftekhar Omi
Asif Iftekhar Omi
AJAnyu Jiang
Anyu Jiang
BCBaibhab Chatterjee
Baibhab Chatterjee
In the context of implantable bioelectronics, this work provides new insights into maximizing biomedical wireless power transfer (BWPT) via the systematic development of inductive links. This approach addresses the specific challenges of power transfer efficiency (PTE) optimization within the spatial/area constraints of bio-implants embedded in tissue. Key contributions include the derivation of an optimal self-inductance with S-parameter-based analyses leading to the codesign of planar spiral coils and L-section impedance matching networks. To validate the proposed design methodology, two coil prototypes— one symmetric (type-1) and one asymmetric (type- 2)— were fabricated and tested for PTE in pork tissue. Targeting a 20 MHz design frequency, the type-1 coil demonstrated a state-of-the-art PTE of ~ 4% (channel length = 15 mm) with a return loss (RL) > 20 dB on both the input and output sides, within an area constraint of < 18×18 mm2. In contrast, the type-2 coil achieved a PTE of ~ 2% with an RL > 15 dB, for a smaller receiving coil area of < 5×5 mm2 for the same tissue environment. To complement the coils, we demonstrate a 65 nm test chip with an integrated energy harvester, which includes a 30-stage rectifier and low-dropout regulator (LDO), producing a stable ~ 1V DC output within tissue medium, matching theoretical predictions and simulations. Furthermore, we provide a robust and comprehensive guideline for advancing efficient inductive links for various BWPT applications, with shared resources in GitHub available for utilization by the broader community.

5 August 2026 in Advanced Science
Verified
Journal Article
Open access
PDF file
HWHan Wu
Han Wu
SMSultan Mahmud
Sultan Mahmud
MHMali Halac
Mali Halac
Asif Iftekhar OmiAsif Iftekhar Omi
Asif Iftekhar Omi
DRDomenica Sofia Baez Rodas
Domenica Sofia Baez Rodas
AKAdam Khalifa
Adam Khalifa
Electroceutical implants that deliver targeted neural stimulation have shown therapeutic potential for a wide range of neurological and peripheral disorders, yet wirelessly powering ultra‐miniaturized, fully injectable systems remains a critical challenge. Here, we report a Thread‐like Injectable Neural TechnologY (TINY) based on differential tissue‐coupled powering (DTCP), which transmits energy through tissue using MHz‐range differential fields generated by a compact, wearable transmitter. DTCP allows power harvesting to scale with implant length rather than cross‐section, enabling a flexible, thread‐like implant that integrates a custom ASIC with PEDOT‐coated receiver and stimulation electrodes. Benchtop experiments in tissue‐mimicking agar phantoms characterize power‐transfer efficiency (PTE) and reveal that PTE increases with implant length while remaining highly tolerant to angular misalignment. In vivo tests in rat hindlimbs further demonstrate wireless sciatic nerve activation through tissue at centimeter‐scale depths, confirming effective transcutaneous energy delivery for neurostimulation. A 20‐day implantation study provides a short‐term/subacute assessment of device positioning and local tissue response. Together, these findings address long‐standing challenges in wirelessly powering injectable electroceuticals and establish DTCP as a scalable and alignment‐robust powering strategy for future minimally invasive neuromodulation therapies.

12 November 2026 in ACM Transactions on Design Automation of Electronic Systems
Verified
Journal Article
Open access
AYAaron Haohua Yen
Aaron Haohua Yen
BJBelal Jahannia
Belal Jahannia
RSRussell Schwartz
Russell Schwartz
AJAnyu Jiang
Anyu Jiang
HYHangbo Yang
Hangbo Yang
PGPuneet Gupta
Puneet Gupta
This article describes a system for modeling nonidealities in a silicon-photonic joint transform correlator (JTC) used as an accelerator for convolutional neural networks (CNNs). The system is used to determine which nonidealities have the greatest impact on end-to-end model accuracy, which helps determine what design choices can be made at the block and system level to improve performance. We create a digital twin of the on-chip 1D JTC using transfer functions fitted from simulations, then introduce a scalar α that mixes ideal and realized behaviors. We quantify the α-dependent model accuracy on CIFAR-10 and SNDR differences at both the joint power spectrum (JPS) and the JTC output. The framework allows quantification of block- and system-level sensitivities, informing design choices by isolating the accuracy bottlenecks within the system.

1 January 2026 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
ABAyan Biswas
Ayan Biswas
AJAnyu Jiang
Anyu Jiang
ADArunashish Datta
Arunashish Datta
Asif Iftekhar OmiAsif Iftekhar Omi
Asif Iftekhar Omi
BCBaibhab Chatterjee
Baibhab Chatterjee
SSShreyas Sen
Shreyas Sen