Nathalie Pons-Kerjean

Nathalie Pons-Kerjean

Auto-generated profile, based on publicly available information

Nathalie Pons-Kerjean

Pharmacie, Louis-Mourier, 178, rue des Renouillers, 92700 Colombes, France

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
JFJustine Frija-Masson
Justine Frija-Masson
JMJimmy Mullaert
Jimmy Mullaert
EVEmmanuelle Vidal-Petiot
Emmanuelle Vidal-Petiot
NPNathalie Pons-Kerjean
Nathalie Pons-Kerjean
MFMartin Flamant
Martin Flamant
MDMarie-Pia D'ORtho
Marie-Pia D'ORtho
Background: Smart scales are increasingly used at home by patients to monitor their body weight and body composition, but scale accuracy has not often been documented. Objective: The goal of the research was to determine the accuracy of 3 commercially available smart scales for weight and body composition compared with dual x-ray absorptiometry (DEXA) as the gold standard. Methods: We designed a cross-sectional study in consecutive patients evaluated for DEXA in a physiology unit in a tertiary hospital in France. There were no exclusion criteria except patient declining to participate. Patients were weighed with one smart scale immediately after DEXA. Three scales were compared (scale 1: Body Partner [Téfal], scale 2: DietPack [Terraillon], and scale 3: Body Cardio [Nokia Withings]). We determined absolute error between the gold standard values obtained from DEXA and the smart scales for body mass, fat mass, and lean mass. Results: The sample for analysis included 53, 52, and 48 patients for each of the 3 tested smart scales, respectively. The median absolute error for body weight was 0.3 kg (interquartile range [IQR] –0.1, 0.7), 0 kg (IQR –0.4, 0.3), and 0.25 kg (IQR –0.10, 0.52), respectively. For fat mass, absolute errors were –2.2 kg (IQR –5.8, 1.3), –4.4 kg (IQR –6.6, 0), and –3.7 kg (IQR –8.0, 0.28), respectively. For muscular mass, absolute errors were –2.2 kg (IQR –5.8, 1.3), –4.4 kg (IQR –6.6, 0), and –3.65 kg (IQR –8.03, 0.28), respectively. Factors associated with fat mass measurement error were weight for scales 1 and 2 (P=.03 and P<.001, respectively), BMI for scales 1 and 2 (P=.034 and P<.001, respectively), body fat for scale 1 (P<.001), and muscular and bone mass for scale 2 (P<.001 for both). Factors associated with muscular mass error were weight and BMI for scale 1 (P<.001 and P=.004, respectively), body fat for scales 1 and 2 (P<.001 for both), and muscular and bone mass for scale 2 (P<.001 and P=.002, respectively). Conclusions: Smart scales are not accurate for body composition and should not replace DEXA in patient care. Trial Registration: ClinicalTrials.gov NCT03803098; https://clinicaltrials.gov/ct2/show/NCT03803098

1 November 2009 in Annales Pharmaceutiques Françaises
Verified
Journal Article
Closed access
CDC. Duez
C. Duez
NPN. Pons-Kerjean
N. Pons-Kerjean
FPF. Paycha
F. Paycha
MCM. Callanquin
M. Callanquin

9 June 2023 in European Journal of Hospital Pharmacy
Verified
Journal Article
Closed access
PDF file
MGMarie-Pauline Gagaille
Marie-Pauline Gagaille
VLVincent Leclerc
Vincent Leclerc
JAJeanne Allard
Jeanne Allard
FMFlorent Marty
Florent Marty
BTBleuenn Treguier
Bleuenn Treguier
NPNathalie Pons-Kerjean
Nathalie Pons-Kerjean
Objectives Anticancer drug preparation control is essential to ensure quality and patient safety. Drugcam (Eurekam Company) is a digital video-assisted control system based on artificial intelligence methods to identify vials used and volumes withdrawn. As for any control system, qualification is required before use in a chemotherapy compounding unit (CCU). Methods We conducted an operational qualification (sensitivity, specificity and accuracy assessment of vials and volumes recognition and quantitative analysis of measured volumes) and a performance qualification (comparison with visual control) of Drugcam in our CCU, as well as an impact study on compounding time and compound supply time. Results Sensitivity, specificity and accuracy of vials (94%, 98% and 96%, respectively) and volumes (86%, 96% and 91%, respectively) recognition are satisfactory. It depends on both the object presented and the camera tested. False positives, which could lead to release of non-compliant preparation, were detected. Volume reading errors may exceed the tolerance threshold of ±5% for small volumes. Drugcam did not significantly lengthen compounding time and compound supply time. Conclusions No recommendations for a qualification method of this new type of control equipment exist. However, a qualification process is essential to understand tool limitations and integrate them into the CCU risk management system. Drugcam enables anticancer drug preparation to be secure and is also useful for initial and continuous staff training.

1 December 2017 in Le Pharmacien Hospitalier et Clinicien
Verified
Journal Article
Closed access
CSClément Salque
Clément Salque
ESEden Shwartz
Eden Shwartz
MBMarc-Antoine Bildan
Marc-Antoine Bildan
MKMaryline Kauss-Hornecker
Maryline Kauss-Hornecker
DPDelphine Pozzi
Delphine Pozzi
NPNathalie Pons-Kerjean
Nathalie Pons-Kerjean

1 December 2017 in Le Pharmacien Hospitalier et Clinicien
Verified
Journal Article
Closed access
MBMarc-Antoine Bildan
Marc-Antoine Bildan
LSLaïly Sadozai
Laïly Sadozai
MKMarilyne Kauss-Hornecker
Marilyne Kauss-Hornecker
DPDelphine Pozzi
Delphine Pozzi
NPNathalie Pons-Kerjean
Nathalie Pons-Kerjean

1 December 2016 in Le Pharmacien Hospitalier et Clinicien
Verified
Journal Article
Closed access
IRIrina Rotaru
Irina Rotaru
RLRachida Lebtahi
Rachida Lebtahi
NPNathalie Pons-Kerjean
Nathalie Pons-Kerjean
MRMakrem Ben Reguiga
Makrem Ben Reguiga