Chiranjit Biswas

Chiranjit Biswas

Auto-generated profile, based on publicly available information

Chiranjit Biswas

Department of Information Technology, Tripura University, Agartala, India

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
CBChiranjit Biswas
Chiranjit Biswas
SCSoham Chakraborty
Soham Chakraborty
KPKamakshi Patro
Kamakshi Patro
JNJyotsna Nain
Jyotsna Nain
ACAbanishwar Chakrabarti
Abanishwar Chakrabarti
SBSujit K. Biswas
Sujit K. Biswas
This article presents a fast and accurate active islanding detection scheme for a grid-tied voltage source inverter (VSI). In the proposed scheme, the VSI generates a small negative sequence voltage to continuously inject a small negative sequence current into the system. The voltage at the point of common coupling (PCC) is measured and the negative sequence component of PCC voltage is extracted. The negative sequence voltage generated by the VSI and the negative sequence voltage at PCC are combined to yield a time-invariant coefficient, which is proposed here to be used for islanding detection. In case detection is done solely based on the magnitude of negative sequence voltage at PCC, higher threshold has to be set as a small magnitude of negative sequence voltage at PCC may also be present due to grid unbalance and other transient events. In the proposed scheme, the islanding detection coefficient depends on the similarity between the injected and measured negative sequence voltage and hence is not dependent on the absolute magnitude of the negative sequence voltage. Thus a very low magnitude of negative sequence current can be injected to effectively detect islanding conditions without a significant impact on power quality. Simulation results show that the proposed scheme is effective for unbalanced grid voltage, or unbalanced load, even in the presence of noise in acquired data. Experimental studies on a laboratory prototype validate the performance of the proposed islanding detection scheme.

9 February 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
CBChiranjit Biswas
Chiranjit Biswas
ACAbanishwar Chakrabarti
Abanishwar Chakrabarti
SMSwanirbhar Majumder
Swanirbhar Majumder
AJAnindita Jamatia
Anindita Jamatia