24 November 2020 in IEEE Transactions on Industry Applications
Multi-Level Inverters (MLI) has wide applications due to their numerous advantages. An improved configuration of eleven-level MLI suitable for medium voltage range has been proposed in this paper. The proposed topology contains two half-bridge sub-modules (HBSM), one flying capacitor (FC) MLI and one full bridge sub-module (FBSM). A simple method of capacitor voltages balancing (CVB) has been demonstrated with less ripple. The study about the effectiveness of proposed MLI has been justified by loss calculation to find efficiency and voltage ripple analysis of capacitor. The comparative assessment in terms of switch count, driver count, capacitor requirement, device peak inverse voltage (PIV), total standing voltage (TSVp.u), cost function etc. for developed hybrid inverter (HI) topology has been presented to establish the utility of the proposed HI. This topology has been checked for its operation under various operating conditions including frequency and modulation index (MI) variation, over-modulation range and also with motor load. The grid connectivity option of the proposed HI has been verified to ensure the suitability for application with renewables.
8 September 2020 in IEEE Transactions on Industry Applications
This paper proposes the integration of a battery energy storage system in a doubly-fed induction generator based wind energy conversion system. A modified triple star bridge cell converter is proposed for the control of doubly fed induction generator and battery energy storage system. The modular structure of the converter facilitates the integration of large energy storage using low rated converters. A median filter is used to segregate the fluctuating component of power generation because of wind speed variation. A control strategy is proposed to mitigate a part of this fluctuation within the rating of the battery energy storage system thereby reducing the fluctuation of power fed to the grid. Wind velocity at an interval of 30second is obtained from online resources and the performance of the proposed algorithm is evaluated via a simulation study. A wind turbine is emulated in a separately excited DC motor and the performance of the proposed scheme is experimentally validated in a laboratory prototype
2 May 2021 in IET Power Electronics
This study presents a winding open‐circuit fault‐tolerant control scheme for an open‐end induction motor drive with common DC bus for dual inverters. The proposed control scheme also permits balanced three‐phase operation of the same motor under healthy operation. It can suppress common mode current easily, yet permits maximum DC bus utilisation in both operating modes. It is mathematically established here that during fault‐tolerant operation, the magnetising current increases by a factor of √3. As a result, the airgap flux during fault‐tolerant operation is same as that during balanced three‐phase operation. An analytical relation is proposed for maximum torque capability of the machine during fault‐tolerant operation, taking into account the limit of winding current to its rated value and increase of magnetising current during such an operation. Extensive mathematical analysis is supported by simulation and experimental results to validate the performance of the proposed scheme during balanced three‐phase operation as well as winding open‐circuit fault‐tolerant operation.
25 July 2023 in IEEE Transactions on Transportation Electrification
An Electric Vehicle (EV) charging scheme is proposed using a transformer isolated 3-phase 4-wire two level pulse width modulated fault-tolerant active front end converter (AFEC) followed by DC-DC converters for charge control. The AFEC is controlled to exhibit fault tolerant operation with balanced 3-phase supply line currents at unity displacement factor (DF) in the event of zero current in one line of the converter. While existing fault-tolerant schemes incorporate additional hardware switchover in the form of the redundant leg for the open circuit fault of one phase, the proposed scheme can maintain balanced supply line current at unity DF using a modified control scheme without any additional hardware during an open circuit failure of either a leg of AFEC, line reactor, connecting cable or one secondary phase of transformer. The proposed scheme uses a method of re-adjusting the phase positions of the converter controlled line currents using the Delta(Δ)-Star(Y) isolation transformer. The scheme can be conveniently used to enhance fault tolerant capability of EV charging stations. Simulation and experimental results validate the effectiveness of the proposed scheme.
3 October 2022 in IEEE Transactions on Industrial Electronics
A generalized Carrier-Based Pulse Width Modulation (CB-PWM) scheme is proposed here for the elimination of common-mode voltage (CMV) in a multilevel multiphase voltage source inverter (VSI). In this CB-PWM scheme, the switching function of x-level, q-phase VSI is obtained from the switching function of virtual y-level and (y+1) level, q-phase VSI, where y = (x+1)/2 when x is odd and y = x/2 when x is even. It is established here that the pole voltages of q-phase x-level VSI thus obtained generate zero CMV. The proposed CB-PWM technique is computationally less intensive and hence can be easily implemented in hardware. Extensive simulation and experimental results are presented to validate the proposed CMV elimination technique in 3-phase 7-level VSI, 5-phase 5-level VSI, and 6-phase 4-level VSI. A comparative study of the proposed PWM scheme with the existing technique shows the superiority of the proposed technique in eliminating CMV.
30 December 2024 in IEEE Transactions on Industry Applications
This article presents a fast and accurate active islanding detection scheme for a grid-tied voltage source inverter (VSI). In the proposed scheme, the VSI generates a small negative sequence voltage to continuously inject a small negative sequence current into the system. The voltage at the point of common coupling (PCC) is measured and the negative sequence component of PCC voltage is extracted. The negative sequence voltage generated by the VSI and the negative sequence voltage at PCC are combined to yield a time-invariant coefficient, which is proposed here to be used for islanding detection. In case detection is done solely based on the magnitude of negative sequence voltage at PCC, higher threshold has to be set as a small magnitude of negative sequence voltage at PCC may also be present due to grid unbalance and other transient events. In the proposed scheme, the islanding detection coefficient depends on the similarity between the injected and measured negative sequence voltage and hence is not dependent on the absolute magnitude of the negative sequence voltage. Thus a very low magnitude of negative sequence current can be injected to effectively detect islanding conditions without a significant impact on power quality. Simulation results show that the proposed scheme is effective for unbalanced grid voltage, or unbalanced load, even in the presence of noise in acquired data. Experimental studies on a laboratory prototype validate the performance of the proposed islanding detection scheme.