17 January 2014 in Biotechnology for Biofuels
Background: The microbial fuel cell represents a novel technology to simultaneously generate electric power and treat wastewater. Both pure organic matter and real wastewater can be used as fuel to generate electric power and the substrate type can influence the microbial community structure. In the present study, rice straw, an important feedstock source in the world, was used as fuel after pretreatment with diluted acid method for a microbial fuel cell to obtain electric power. Moreover, the microbial community structures of anodic and cathodic biofilm and planktonic culturewere analyzed and compared to reveal the effect of niche on microbial community structure. Results: The microbial fuel cell produced a maximum power density of 137.6 ± 15.5 mW/m2 at a COD concentration of 400 mg/L, which was further increased to 293.33 ± 7.89 mW/m2 through adjusting the electrolyte conductivity from 5.6 mS/cm to 17 mS/cm. Microbial community analysis showed reduction of the microbial diversities of the anodic biofilm and planktonic culture, whereas diversity of the cathodic biofilm was increased. Planktonic microbial communities were clustered closer to the anodic microbial communities compared to the cathodic biofilm. The differentiation in microbial community structure of the samples was caused by minor portion of the genus. The three samples shared the same predominant phylum of Proteobacteria. The abundance of exoelectrogenic genus was increased with Desulfobulbus as the shared most abundant genus; while the most abundant exoelectrogenic genus of Clostridium in the inoculum was reduced. Sulfate reducing bacteria accounted for large relative abundance in all the samples, whereas the relative abundance varied in different samples. Conclusion: The results demonstrated that rice straw hydrolysate can be used as fuel for microbial fuel cells; microbial community structure differentiated depending on niches after microbial fuel cell operation; exoelectrogens were enriched; sulfate from rice straw hydrolysate might be responsible for the large relative abundance of sulfate reducing bacteria.
1 June 2019 in Bioelectrochemistry
9 August 2016 in Environmental Technology
Separator is important to prevent bio-contamination of the catalyst layer of air-diffusion cathode microbial fuel cells (MFCs). Mixed cellulose ester filter (MCEF) was examined as a separator for an air-cathode MFC in the present study. The MCEF-MFC produced a maximum power density of 780.7 ± 18.7 mW/m2, which was comparable to 770.9 ± 35.9 mW/m2 of MFC with Nafion membrane (NFM) as a separator. Long-term examination demonstrated a more stable performance of the MCEF-MFC than NFM-MFC. After 25 cycles, the maximum voltage of the MCEF-MFC decreased by only 1.3% from 425.1 ± 4.3 mV (initial 5 cycles) to 419.5 ± 2.3 mV (last 5 cycles). However, it was decreased by 9.1% from 424.8 ± 5.7 to 386 ± 2.5 mV for the NFM-MFC. The coulombic efficiency (CE) of the MCEF-MFC did not change (from 3.11 ± 0.09% to 3.13 ± 0.02%), while it decreased by 9.12% from 3.18 ± 0.04% to 2.89 ± 0.02% for the NFM-MFC. The MCEF separator was with less biofouling than the NFM separator over 60 days’ operation, which might be the reason for the more table long-term performance of the MCEF-MFC. The results demonstrated that MCEF was feasible as a separator to set up good-performing and cost-effective air-diffusion cathode MFC.
1 March 2004 in Water Science & Technology
This study was performed to increase the treatment efficiency and to reduce operation and maintenance costs of the existing nightsoil treatment plant. The existing nightsoil plant was not established by the nitrogen removal process, and was operated ineffectively with deterioration of treatment efficiency rate, and according to the demand of many operators, the expenses of operation and maintenance have become excessive. Modified plant has been changed through two steps. The first step, liquid decayed tank using closed oxidation ditch is operated to increase retention time only for nitrification. The second step, modified liquid decayed tank including anoxic tank is operated, it has an excellent nitrogen removal rate. In first step, when HRT was increased from 10 days to 13 days in liquid decayed tank including aeration tank using closed oxidation ditch, TN concentration of effluent appeared below 51 mg/l less than discharge limit, 60 mg/L. In second step, when anoxic tank and oxic tank were installed, HRT has been increased to 13 days and 26 days, respectively. Then average TN concentration of effluent was detected less than 13 mg/L for over one year. The simple process modified the existing two processes resulted in the reduction of costs for operation and maintenance in the personnel, chemical, and filter change sphere.