Pia Rademann

Pia Rademann

Auto-generated profile, based on publicly available information

Pia Rademann

University Hospital of Cologne, Köln, Deutschland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in International Journal of Hyperthermia
Verified
Journal Article
Open access
LSLukas Christian Sebeke
Lukas Christian Sebeke
PRPia Rademann
Pia Rademann
AMAlexandra Claudia Maul
Alexandra Claudia Maul
SYSin Yuin Yeo
Sin Yuin Yeo
JGJuan Daniel Castillo Gómez
Juan Daniel Castillo Gómez
EHEdwin Heijman
Edwin Heijman
This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the...

1 January 2020 in International Journal of Hyperthermia
Verified
Journal Article
Open access
LSLukas Christian Sebeke
Lukas Christian Sebeke
PRPia Rademann
Pia Rademann
AMAlexandra Claudia Maul
Alexandra Claudia Maul
CSClaudia Schubert-Quecke
Claudia Schubert-Quecke
TAThorsten Annecke
Thorsten Annecke
EHEdwin Heijman
Edwin Heijman
Purpose: Pancreatic cancer is typically diagnosed in a late stage with limited therapeutic options. For those patients, ultrasound-guided high-intensity focused ultrasound (US-HIFU) can improve local control and alleviate pain. However, MRI-guided HIFU (MR-HIFU) has not yet been studied extensively in this context. To facilitate related research and accelerate clinical translation, we report a workflow for the in vivo HIFU ablation of the porcine pancreas under MRI guidance. Materials and methods: The pancreases of five healthy German landrace pigs (35–58 kg) were sonicated using a clinical MR-HIFU system. Acoustic access to the pancreas was supported by a specialized diet and a hydrogel compression device for bowel displacement. Organ motion was suspended using periods of apnea. The size of the resulting thermal lesions was assessed using the thermal threshold- and dose profiles, non-perfused volume, and gross examination. The effect of the compression device on beam path length was assessed using MRI imaging. Results: Eight of ten treatments resulted in clearly visible damage in the target tissue upon gross examination. Five treatments resulted in coagulative necrosis. Good agreement between the four metrics for lesion size and a clear correlation between the delivered energy dose and the resulting lesion size were found. The compression device notably shortened the intra-abdominal beam path. Conclusions: We demonstrated a workflow for HIFU treatment of the porcine pancreas in-vivo under MRI-guidance. This development bears significance for the development of MR-guided HIFU interventions on the pancreas as the pig is the preferred animal model for the translation of pre-clinical research into clinical application.

1 January 2022 in The Thoracic and Cardiovascular Surgeon
Verified
Journal Article
Closed access
Ilija DjordjevicIlija Djordjevic
Ilija Djordjevic
JMJ. Maier-Trauth
J. Maier-Trauth
Stephen GerferStephen Gerfer
Stephen Gerfer
MEM. Elskamp
M. Elskamp
TMT. Mühlbauer
T. Mühlbauer
TWT. Wahlers
T. Wahlers
Background: Fluid resuscitation is a necessary part of therapeutic measures to maintain sufficient hemodynamic in extracorporeal membrane oxygenation (ECMO) circulation. We aimed to investigate in a post-hoc analysis the impact of increased volume therapy during ECMO circulation on renal function and organ edema in a large animal model. Method: ECMO therapy was performed in 12 female pigs (Deutsche Landrasse × Pietrain) for 10 hours. Application volume, in regard to necessary maintenance of hemodynamics, was divided into moderate in extensive volume therapy (MVT/EVT) due to the double quantity of calculated physiologic urine output for the planed study period. Respiratory and hemodynamic data were measured continuously. Additionally, renal function and organ edema were assessed by blood and tissue samples. Results: Four pigs were included in MVT group and eight pigs were analyzed in EVT group. After 10 hours of ECMO circulation, no major differences were seen between the groups in regard of hemodynamic and respiratory data. Relative change of creatinine after 10 hours ECMO support was significantly higher in EVT (1.3 ± 0.3 MVT vs. 1.8 ± 0.5 EVT; p = 0.033). No major differences were evident for lung, heart, liver, and kidney samples in regard of the organ edema in comparison of EVT and MVT. Bowel tissue showed higher percentage of edema in EVT compared with MVT (77 ± 2% MVT vs. 80 ± 3% EVT; p = 0.049). Conclusion: Presented data suggest potential deterioration of renal and intestinal mucosa function by increase in tissue edema due to administered volume overload during ECMO therapy. Publication Date: 03 February 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany