1 January 2019 in International Journal of Hyperthermia
Verified
Journal Article
Open access
LSL. Sebeke
L. Sebeke
DDD. A. Deenen
D. A. Deenen
EME. Maljaars
E. Maljaars
EHE. Heijman
E. Heijman
BJB. de Jager
B. de Jager
HGHolger Gruell
Holger Gruell
Purpose: In local hyperthermia, precise temperature control throughout the entire target region is key for swift, safe, and effective treatment. In this article, we present a model predictive control (MPC) algorithm providing voxel-level temperature control in magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) and assess the improvement in performance it provides over the current state of the art. Materials and methods: The influence of model detail on the prediction quality and runtime of the controller is evaluated and a tissue mimicking phantom is characterized using the resulting model. Next, potential problems arising from modeling errors are evaluated in silico and in the characterized phantom. Finally, the controller’s performance is compared to the current state-of-the-art hyperthermia controller in side-by-side experiments. Results: Modeling diffusion by heat exchange between four neighboring voxels achieves high predictive performance and results in runtimes suited for real-time control. Erroneous model parameters deteriorate the MPC’s performance. Using models derived from thermometry data acquired during low powered test sonications, however, high control performance is achieved. In a direct comparison with the state-of-the-art hyperthermia controller, the MPC produces smaller tracking errors and tighter temperature distributions, both in a homogeneous target and near a localized heat sink. Conclusion: Using thermal models deduced from low-powered test sonications, the proposed MPC algorithm provides good performance in phantoms. In direct comparison to the current state-of-the-art hyperthermia controller, MPC performs better due to the more finely tuned heating patterns and therefore constitutes an important step toward stable, uniform hyperthermia.

1 January 2021 in International Journal of Hyperthermia
Verified
Journal Article
Open access
LSLukas Christian Sebeke
Lukas Christian Sebeke
PRPia Rademann
Pia Rademann
AMAlexandra Claudia Maul
Alexandra Claudia Maul
SYSin Yuin Yeo
Sin Yuin Yeo
JGJuan Daniel Castillo Gómez
Juan Daniel Castillo Gómez
EHEdwin Heijman
Edwin Heijman
This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the...

1 January 2020 in International Journal of Hyperthermia
Verified
Journal Article
Open access
LSLukas Christian Sebeke
Lukas Christian Sebeke
PRPia Rademann
Pia Rademann
AMAlexandra Claudia Maul
Alexandra Claudia Maul
CSClaudia Schubert-Quecke
Claudia Schubert-Quecke
TAThorsten Annecke
Thorsten Annecke
EHEdwin Heijman
Edwin Heijman
Purpose: Pancreatic cancer is typically diagnosed in a late stage with limited therapeutic options. For those patients, ultrasound-guided high-intensity focused ultrasound (US-HIFU) can improve local control and alleviate pain. However, MRI-guided HIFU (MR-HIFU) has not yet been studied extensively in this context. To facilitate related research and accelerate clinical translation, we report a workflow for the in vivo HIFU ablation of the porcine pancreas under MRI guidance. Materials and methods: The pancreases of five healthy German landrace pigs (35–58 kg) were sonicated using a clinical MR-HIFU system. Acoustic access to the pancreas was supported by a specialized diet and a hydrogel compression device for bowel displacement. Organ motion was suspended using periods of apnea. The size of the resulting thermal lesions was assessed using the thermal threshold- and dose profiles, non-perfused volume, and gross examination. The effect of the compression device on beam path length was assessed using MRI imaging. Results: Eight of ten treatments resulted in clearly visible damage in the target tissue upon gross examination. Five treatments resulted in coagulative necrosis. Good agreement between the four metrics for lesion size and a clear correlation between the delivered energy dose and the resulting lesion size were found. The compression device notably shortened the intra-abdominal beam path. Conclusions: We demonstrated a workflow for HIFU treatment of the porcine pancreas in-vivo under MRI-guidance. This development bears significance for the development of MR-guided HIFU interventions on the pancreas as the pig is the preferred animal model for the translation of pre-clinical research into clinical application.

1 January 2020 in IFAC-PapersOnLine
Verified
Journal Article
Open access
DDD.A. Deenen
D.A. Deenen
EME. Maljaars
E. Maljaars
LSL. Sebeke
L. Sebeke
BJB. de Jager
B. de Jager
EHE. Heijman
E. Heijman
WHW.P.M.H. Heemels
W.P.M.H. Heemels
In hyperthermia treatments, cancer tissue is heated to enhance the desired effects of radio- and chemotherapies. A powerful technology for noninvasive feedback-controlled hyperthermia is magnetic-resonance-guided high-intensity focused ultrasound (MR-HIFU), which enables fast and millimeter-accurate heating inside the body. Electronic beam steering allows for volumetric heating, but due to its limited steering range can only be used to treat small tumors. For the treatment of larger tumors, the transducer itself must be mechanically relocated as well. Due to system limitations, however, the admissible transducer positions must be restricted to a finite set that is chosen a priori. Moreover, non-negligible time is needed for transducer relocation, during which no heating is possible. In this paper, we present a mixed-integer model predictive controller that simultaneously optimizes over the power deposition by electronic beam steering - a continuous subproblem - as well as the mechanical transducer motions - a discrete subproblem. By incorporating model knowledge of the tissue’s thermal response and of the transducer carrier motion system into the predictive algorithm, the controller optimizes treatment temperature while respecting temperature and actuation constraints. The performance of the proposed feedback control setup is demonstrated by means of simulation.

23 November 2023 in International Journal of Hyperthermia
Verified
Journal Article
Open access
SNSven Nouwens
Sven Nouwens
Margarethus PaulidesMargarethus Paulides
Margarethus Paulides
JLJohannes Lindemeyer
Johannes Lindemeyer
LSLukas Sebeke
Lukas Sebeke
RKRicky van Kampen
Ricky van Kampen
MHMaurice Heemels
Maurice Heemels
Purpose: A crucial aspect of quality assurance in thermal therapy is periodic demonstration of the heating performance of the device. Existing methods estimate the specific absorption rate (SAR) from the temperature rise after a short power pulse, which yields a biased estimate as thermal diffusion broadens the apparent SAR pattern. To obtain an unbiased estimate, we propose a robust frequency-domain method that simultaneously identifies the SAR as well as the thermal dynamics.Methods: We propose a method consisting of periodic modulation of the FUS power while recording the response with MR thermometry (MRT). This approach enables unbiased measurements of spatial Fourier coefficients that encode the thermal response. These coefficients are substituted in a generic thermal model to simultaneously estimate the SAR, diffusivity, and damping. The method was tested using a cylindrical phantom and a 3 T clinical MR-HIFU system. Three scenarios with varying modulation strategies are chosen to challenge the method. The results are compared to the well-known power pulse technique.Results: The thermal diffusivity is estimated at 0.151 mm2s-1 with a standard deviation of 0.01 mm2s-1 between six experiments. The SAR estimates are consistent between all experiments and show an excellent signal-to-noise ratio (SNR) compared to the well established power pulse method. The frequency-domain method proved to be insensitive to B0-drift and non steady-state initial temperature distributions.Conclusion: The proposed frequency-domain estimation method shows a high SNR and provided reproducible estimates of the SAR and the corresponding thermal diffusivity. The findings suggest that frequency-domain tools can be highly effective at estimating the SAR from (biased) MRT data acquired during periodic power modulation.