Ali Zamani

Ali Zamani

Auto-generated profile, based on publicly available information

Ali Zamani

Department of Medical Physics and Biomedical Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2014 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
SSShoaleh Shahidi
Shoaleh Shahidi
EBEhsan Bahrampour
Ehsan Bahrampour
ESElham Soltanimehr
Elham Soltanimehr
AZAli Zamani
Ali Zamani
MOMorteza Oshagh
Morteza Oshagh
AMAlireza Mehdizadeh
Alireza Mehdizadeh
Two-dimensional projection radiographs have been traditionally considered the modality of choice for cephalometric analysis. To overcome the shortcomings of two-dimensional images, three-dimensional computed tomography (CT) has been used to evaluate craniofacial structures. However, manual landmark detection depends on medical expertise, and the process is time-consuming. The present study was designed to produce software capable of automated localization of craniofacial landmarks on cone beam (CB) CT images based on image registration and to evaluate its accuracy.

10 April 2008 in IET Radar, Sonar & Navigation
Verified
Journal Article
Closed access
MSMohammad Hossein Sheikhi
Mohammad Hossein Sheikhi
AZA. Zamani
A. Zamani
The superiority of multiple-input multiple-output (MIMO) radars over conventional phased-array radars has been recently shown in many aspects. The MIMO radars have better detection performance and can extract target information more precisely than phased-array radars. The problem of adaptive target detection using temporal coherent pulse train in the presence of nonhomogeneous clutter (different clutter statistics in receivers) is considered for MIMO radars. This problem has been formulated as a hypothesis test. For clutter with unknown statistics three adaptive decision rules have been developed using the generalised likelihood ratio test. The results show the superiority of the MIMO radars with temporal coherent processing over conventional phased arrays in the presence of clutter.

1 June 2019 in Journal of Biomedical Physics and Engineering
Verified
Journal Article
Open access
PDF file
ASA Safari
A Safari
HPHossein Parsaei
Hossein Parsaei
AZA Zamani
A Zamani
BPB Pourabbas
B Pourabbas
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal cord in the given x-ray image of the spine is highlighted using contract-stretching technique. The overall structural curvature of the spine is determined by a semi-automatic algorithm aided by the operator. Once the morphologic curve of the spine is determined, in the last step the cobb-angle is estimated by calculating the angle between two normal lines to the spinal curve at the inflection points of the curve.Results: Evaluation results of the developed algorithms using 14 radiographs of patients ( 4 - 40 years old) with cobb angle ranges from 34 - 82 degrees, revealed that the developed algorithm accurately estimated cobb angle. Statistical analysis showed that average angle values estimated using the developed method and that provided by experts are statistically equal. The correlation coefficient between the angle values estimated using the developed algorithm and those provided by the expert is 0.81.Conclusion: Compared with previous algorithms, the developed system is easy to use, less operator-dependent, accurate, and reliable. The obtained results are promising and show that the developed computer-based system could be used to quantify scoliosis by measuring Cobb angle.

20 March 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MJMohsen Ghofrani Jahromi
Mohsen Ghofrani Jahromi
HPHossein Parsaei
Hossein Parsaei
AZAli Zamani
Ali Zamani
DSDaniel Stashuk
Daniel Stashuk
Feature extraction is an important step of resolving an electromyographic (EMG) signal into its component motor unit potential trains (MUPTs), commonly known as EMG decomposition. Until now, different features have been used to represent motor unit potentials (MUPs) and improve decomposition processing time and accuracy, but a major limitation is that no systematic comparison of features exists. In an EMG decomposition system, like any pattern recognition system, the features used for representing MUPs play an important role in the overall performance of the system. A cross comparison of the feature extraction methods used in EMG signal decomposition can assist in choosing the best features for representing MUPs and ultimately may improve EMG decomposition results. This paper presents a survey and cross comparison of these feature extraction methods. Decomposability Index (DI), classification accuracy of a kNN classifier, and class-feature mutual information were employed for evaluating the discriminative power of various feature extraction techniques commonly used in the literature including time domain, morphological, frequency domain, and discrete wavelets. In terms of data, 45 simulated and 82 real EMG signals were used. Results showed that among time domain features, the first derivative of time samples exhibit the best separability. For morphological features, slope analysis provided the most discriminative power. Discrete Fourier transform coefficients offered the best separability among frequency domain features. However, neither morphological nor frequency domain techniques outperformed time domain features. The detail4 coefficients in a discrete wavelets decomposition exceeded in evaluation measures when compared to other feature extraction techniques. Using principal component analysis slightly improved the results, but it is time consuming. Overall, considering computation time and discriminative ability, the first derivative of time samples might be efficient in representing MUPs in EMG decomposition and there is no need for sophisticated feature extraction methods.

1 July 2019 in Environmental Research
Verified
Journal Article
Closed access
NJNajmeh Jooyan
Najmeh Jooyan
BGBahram Goliaei
Bahram Goliaei
BBBahareh Bigdeli
Bahareh Bigdeli
RFReza Faraji-Dana
Reza Faraji-Dana
AZAli Zamani
Ali Zamani
SMSmj Mortazavi
Smj Mortazavi

2 September 2018 in Journal of Biomedical Physics and Engineering
Verified
Journal Article
Open access
PDF file
MEM Ebrahimian
M Ebrahimian
MRM Razeghi
M Razeghi
AZA Zamani
A Zamani
ZBZ Bagheri
Z Bagheri
KRK Rastegar
K Rastegar
AMA Motealleh
A Motealleh
Background: Transcutaneous electrical nerve stimulation (TENS) is a noninvasive, inexpensive and safe analgesic technique used for relieving acute and chronic pain. However, despite all these advantages, there has been very little research into the therapeutic effects of TENS on brain activity. To the best of our knowledge, there is no evidence on the effect of high frequency TENS on the gamma band activity. Objective: Investigation of the effect of high frequency TENS on the electroencephalographic (EEG) gamma band activity after inducing ischemic pain in healthy volunteers is considered.Methods: The modified version of Submaximal effort tourniquet test was carried out for inducing tonic pain in 15 right-handed healthy volunteers. The high frequency TENS (150µs in duration, frequency of 100 Hz) was applied for 20 minutes. Pain intensity was assessed using Visual Analog Scale (VAS) in two conditions (after-pain, after-TENS). EEG gamma band activity was recorded by a 19-channel EEG in three conditions (baseline, after-pain and after- TENS). The repeated measure ANOVA and paired-sample T- tests were used for data analysis.Results: EEG analysis showed an increase in gamma total power after inducing pain as compared to baseline and a decrease after the application of TENS (mean±SD: .043±.029 to .088±.042 to .038±.022 μV2 ).The analysis of VAS values demonstrated that the intensity of induced pain (mean±SD: 51.53±9.86) decreased after the application of TENS (mean±SD: 18.66±10.28). All these differences were statistically significant (p<.001).Conclusion: The results of this study revealed that the high frequency TENS can reduced the enhanced gamma band activity after the induction of tonic pain in healthy volunteers. This finding might help as a functional brain biomarker which could be useful for pain treatment, specifically for EEG-based neurofeedback approaches.