Lihui Jin

Lihui Jin

Auto-generated profile, based on publicly available information

Lihui Jin

Department of Radiation Oncology, Fox Chase Cancer Center, 333 Cottman Avenue, Philadelphia, Pennsylvania 19111

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Aerospace Science and Technology
Verified
Journal Article
Closed access
HGHaichao Gui
Haichao Gui
LJLei Jin
Lei Jin
SXShijie Xu
Shijie Xu

20 November 2014 in Nonlinear Dynamics
Verified
Journal Article
Closed access
PDF file
HGHaichao Gui
Haichao Gui
LJLei Jin
Lei Jin
SXShijie Xu
Shijie Xu
JZJun Zhang
Jun Zhang

3 October 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
LJLei Jin
Lei Jin
CMC-M Ma
C-M Ma
JFJIANCHANG FAN
JIANCHANG FAN
AEA Eldib
A Eldib
RPR A Price
R A Price
JLJ S Li
J S Li
Modulated electron radiotherapy (MERT) may potentially be an effective modality for the treatment of shallow tumors, but dose calculation accuracy and delivery efficiency challenges remain. The purpose of this work is to investigate the dose accuracy of MERT delivery using a photon multileaf collimator (pMLC) on a Siemens Primus accelerator. A Monte Carlo (MC)-based inverse treatment planning system was developed for the 3D treatment planning process. Phase space data of 6, 9, 12 and 15 MeV electron beams were commissioned and used as the input source for MC dose calculations. A treatment plan was performed based on the 3D CT data of a heterogeneous 'breast phantom' that mimics a breast cancer patient, and delivered with 22 segments, each associated with a particular energy and Monitor Unit value. Film and ion chamber dosimetry was carefully performed for the conversion from measurement reading to dose, and the results were employed for plan verification using the heterogeneous breast phantom and a solid water phantom. Dose comparisons between measurements and calculations showed agreement within 2% or 1 mm. We conclude that our in-house MC treatment planning system is capable of performing treatment planning and accurate dose calculations for MERT using the pMLC to deliver radiation therapy to the intact breast.


19 November 2012 in Acta Astronautica
Verified
Journal Article
Closed access
DWDongxia Wang
Dongxia Wang
YJYinghong Jia
Yinghong Jia
LJLei Jin
Lei Jin
SXShijie Xu
Shijie Xu

3 February 2014 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
AEAhmed Eldib
Ahmed Eldib
LJLihui Jin
Lihui Jin
JLJinsheng Li
Jinsheng Li
CMC-M Charlie Ma
C-M Charlie Ma
Electron beam therapy has been an important radiation therapy modality for many decades. Studies have been conducted recently for more efficient and advanced delivery of electron beam radiation therapy. X-ray contamination is a common problem that exists with all of the advanced electron beam therapy techniques such as Bolus Electron conformal therapy, segmented electron conformal therapy, and modulated electron arc therapy. X-ray contamination could add some limitations to the advancement and clinical utility of those electron modalities. It was previously shown in the literature that the scattering foil is one of the major accelerator parts contributing to the generation of bremsstrahlung photons. Thus, in this work we investigate the dosimetric characteristics of scattering foil free (SFF) electron beams and the feasibility of using those beams for breast cancer boosts. The SFF electron beams were modeled and simulated using the Monte Carlo method. CT scans of six previously treated breast patients were used for the treatment plan generation utilizing our in-house Monte Carlo-based treatment planning system. Electron boost plans with conventional beams and the SFF beams were generated, respectively, for all patients. A significant reduction of the photon component was observed with the removal of the primary scattering foil for beam energies higher than 12 MeV. Flatness was greatly affected but the difference in flatness between conventional and SFF beams was much reduced for small cone sizes, which were often used clinically for breast boosts. It was found that the SFF electron beams could deliver high-quality dose distributions as conventional electron beams for boost treatments of the breast with an added advantage of a further reduced dose to the lung and the heart.