20 July 2017 in IEEE Transactions on Industry Applications
This paper presents a nonlinear technique based on the sliding mode control theory for mitigation of torsional vibrations in grid-connected doubly fed induction generator (DFIG) based wind turbines. The presented method increases the lifespan of wind turbines by reducing torsional vibrations caused by mechanical or electrical disturbances. The effectiveness of the proposed technique is demonstrated on torsional vibrations caused by a voltage dip and a wind gust. In this paper, dynamics of the generator, multiinertia drivetrain, rotor- and grid-side converters, and transmission line are developed upon the 750-kW fatigue, aerodynamics, structures, and turbulence (FAST) simulator wind turbine model comprising wind turbine aerodynamics.
26 October 2020 in IEEE Transactions on Industry Applications
An adaptive virtual-inductance feedforward scheme is presented in this paper to enhance the stable operation of smart inverters in weak grids. In the developed scheme, the virtual-inductance is updated in real-time according to an adaptation law to ensure that the response of the grid-tied inverter follows the dynamic response of a robust reference model, thereby ensuring stability without the need for any grid impedance estimation. In this paper, the developed scheme is validated with experimental results obtained from testing a small-scale 2-level, 208V, 2kW inverter.
11 September 2019 in IEEE Transactions on Transportation Electrification
In a More Electric Aircraft (MEA) design, the onboard electric generators are mechanically coupled directly to the jet engines, thus producing a variable-frequency constant magnitude voltage. This wild-frequency characteristic imposes a new design challenge on the onboard power converters. In this paper, an experimental performance comparison between model predictive and proportional-integral (PI)-based control schemes for active rectifiers in MEA applications is presented. The comparison of the aforementioned controllers is executed under the MEA variable input frequency perspective for the first time and therefore constitutes the main contribution of this work. This comparison mainly addresses the dynamic response of the controllers in terms of dc-bus voltage regulation and unity power factor operation under frequency ramping, frequency step changes, and load step variations. Furthermore, the robustness of the controllers is analyzed in terms of their performance degradation in the presence of parameter mismatch. Both the model predictive and PI-based controllers are experimentally tested using a 1kW SiC-MOSFET two-level voltage-source-converter topology.
2 March 2020 in IEEE Transactions on Transportation Electrification
19 November 2024 in IEEE Transactions on Power Electronics
While wide bandgap (WBG) switches have revolutionized power electronics and motor-drive systems, the high $dv/dt$ associated with these fast-switching semiconductors can easily induce reflected high-frequency overvoltage spikes on motor stator terminals. The shorter rise time of the voltage pulses confines the cable length between the inverter and the motor in practice to avoid overvoltage across the motor stator windings. Even with shorter cables, voltage spikes from variable-speed drives can still cause premature insulation failure and reduce the remaining useful lifetime of the motors. While effective, conventional methods such as $dv/dt$ passive filters or active gate drivers are usually bulky and/or inefficient. To address this problem, an overvoltage mitigation solution, named “Smart Coil”, is introduced in this paper. The smart coil circuit is installed in parallel with the first coil of each motor phase, which typically experiences the highest reflected overvoltage. Upon detection of overvoltage, the proposed ultra-compact smart coil circuit, located at the motor junction box, is activated to limit voltage stress across the coils. Since the smart coil is connected in parallel with the first coil, it only needs to process very low pulsed power during the overvoltage transients. Therefore, it has high efficiency and an ultra-compact footprint while effectively mitigating voltage spikes. The proposed smart coil circuit can be easily scaled for various motor-drive systems regardless of the cable length or rise time of the switching devices. Simulation and experimental test results are provided to verify the effectiveness of the proposed method.
17 June 2025 in IEEE Transactions on Industrial Electronics
High-performance switching devices such as SiC MOSFETs introduce high-frequency ringing and overvoltage transients at motor terminals, leading to uneven voltage distribution across windings. In SiC-driven motors, the first coil and initial turns experience significant overvoltage stress, increasing the risk of insulation degradation and interturn faults. This study proposes an analog circuit to mitigate overvoltage stress. The circuit detects high dv/dt in the first coil and adaptively inserts a ceramic capacitor via a GaN switch, forming a low-impedance path for high-frequency currents. This diverts part of the transient energy to the second coil, reducing stress on the first coil and promoting uniform voltage distribution. The GaN switch remains closed to sustain the high-frequency current path through the capacitor, adapting to different operating conditions and cable lengths. The circuit was prototyped and experimentally validated on a 2hp induction motor driven by a SiC inverter, demonstrating its effectiveness in mitigating overvoltage stress. This compact solution enhances the reliability of SiC-driven motor systems by addressing uneven high-frequency voltage distribution.