Majid Tahmasbi Fard

Majid Tahmasbi Fard

Auto-generated profile, based on publicly available information

Majid Tahmasbi Fard

Department of Electrical and Computer Engineering, University of Kentucky, Lexington, KY, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
MFMajid T. Fard
Majid T. Fard
JiangBiao HeJiangBiao He
JiangBiao He
HHHao Huang
Hao Huang
YCYue Cao
Yue Cao
Global transportation has shifted toward electromobility to achieve net-zero emission, and in the next few decades, commercial electric aircraft is likely to become a reality. This transition has embarked on through the existing more electric aircraft (MEA), and the ultimate goal will be potentially achieved by hybrid-electric and all-electric airliners, along with green fuels, such as green hydrogen or supercritical CO2 (sCO2) and its potential Gg CO2 equivalent elimination—with or without combustion. Electric propulsion replaces conventional jet propulsors with electric fans powered by electric generators rotated by an engine, a combination of generators and energy storage, or just energy storage. An appealing idea is to distribute the electric fans along the aircraft wings or tails to improve aerodynamics, boost energy efficiency, and reduce carbon emissions and acoustic noise. Focusing on distributed electric propulsion (DEP) systems, this article reviews the state-of-the-art advancements in aircraft electrification. Three major DEP categories, i.e., turboelectric, hybrid-electric, and all-electric propulsion technologies, are investigated. Although all of them utilize electric fans as propulsors, their system structures and power generation stages are different. Hence, comprehensive considerations are required to optimize the DEP system designs. Starting with the multifarious electrical system architectures proposed in the literature, a thorough review is conducted including the system parametric specifications, design considerations of power converters, the power electronics devices’ characteristics in cryogenic conditions, and various energy storage systems. This review aims to provide a reference to researchers, engineers, and policy-makers in aviation to accelerate the progress toward future net-zero emissions.

16 May 2018 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
MTMajid Tahmasbi-Fard
Majid Tahmasbi-Fard
MTMehrdad Tarafdar-Hagh
Mehrdad Tarafdar-Hagh
SPSaman Pourpayam
Saman Pourpayam
AHAmir-Aslan Haghrah
Amir-Aslan Haghrah
Partial shading is one of the main causes in reducing the output power of photovoltaic (PV) systems. This paper proposes a circuit to recover the energy of shaded PV modules during partial shading condition (PSC). The proposed circuit, which is a combination of a buck–boost converter and the switched-capacitor (BBSC) circuits, equalizes the voltage of PV modules and prevents bypass diodes from bypassing the shaded modules in a string. Hence, shaded PV modules can have a contribution in output generated power instead of being bypassed. The main features of the BBSC are the utilization of the reduced number of switches in comparison with buck–boost and switched-capacitor circuits, a simple switching control strategy, and fast voltage equalization. In addition, a BBSC circuit is almost a lossless circuit during uniform shading conditions. To validate the effectiveness of the proposed BBSC circuit, both simulation results in PSCAD/EMTDC software and experimental results are presented.

1 June 2016
Verified
Conference Paper
Closed access
MFMajid Fard
Majid Fard
MAMohammad Aldeen
Mohammad Aldeen
A robust H ∞ control design based on linear matrix inequality (LMI) is presented in this paper to control a DC-DC boost converter in a photovoltaic system. The design method considers converter nonlinearities, modelled as a convex polytope, and achieves H ∞ performance, in terms of load disturbance rejection, as well as system stability. A 6kW PV system is considered as an application example to test the designed controller performance in presence and absence of parametric uncertainties. The results comparison shown the better performance and less power dissipation of this approach in compared with direct duty cycle control method. The proposed approach is also compared non-quantitatively and quantitatively with a non-linear LQR controller to elaborate performance superiority of the proposed method. This new approach achieves faster tracking of reference maximum power voltage provided by MPPT with less oscillation.

26 September 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
MFMajid T. Fard
Majid T. Fard
BLBenjamin J. Luckett
Benjamin J. Luckett
JiangBiao HeJiangBiao He
JiangBiao He
This paper presents an innovative digital twin strategy for health monitoring of five-level active neutral point clamped (5L-ANPC) power converters, which are extensively utilized in high-power, safety-critical applications. Despite their widespread use, the reliability of 5L-ANPC inverters is often compromised due to the large number of semiconductor devices employed, posing challenges for their broader deployment in safety-critical applications. The proposed approach introduces a real-time digital twin replica that continuously monitors crucial parameters to assess the inverter’s performance and detect open-circuit faults in the switches. This methodology not only enhances reliability but also reduces maintenance downtime cost. Specifically focusing on open-circuit switching faults, this paper presents a fast online digital twin based fault diagnostic method. The proposed diagnostic technique leverages the existing DC-link capacitor and flying capacitor voltages, along with load current data and switching patterns, eliminating the need for any additional sensors. The detection process takes less than a fundamental period of the inverter output frequency to diagnose any faulty switch accurately. Experimental results validate the robustness and effectiveness of the proposed digital twin health monitoring method across various operating conditions.

3 December 2019 in International Journal of Electronics
Verified
Journal Article
Closed access
MFMajid Tahmasbi Fard
Majid Tahmasbi Fard
MHMehrdad Tarafdar Hagh
Mehrdad Tarafdar Hagh
This paper presents a current source inverter (CSI)-based hybrid power generation system, which uses wind turbine and photovoltaic cells (PVs). A permanent magnet synchronous generator (PMSG) is connected to the CSI using a diode rectifier and a buck converter that is used to control the speed of the rotor. Another buck converter is used to control the maximum power point tracking of PVs. The operation of proposed system is studied under normal and grid voltage dip conditions. According to new grid codes, most power generating units are supposed to remain connected to the grid during voltage sag conditions and inject reactive current to grid as defined by grid codes. The CSI has fault current limiting capability that makes it appropriate to use in grid-connected applications and during voltage sag conditions in particular. The proposed system tracks the maximum power point of wind turbine and PVs under normal mode and injects required reactive current to the grid during voltage drop. However, incorporation of CSI with the inherent behaviour of wind turbine and PVs causes fault current to be within the tolerable range for power electronic devices. Simulations are carried out by using PSCAD/EMTDC software to verify the proposed system.

19 November 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MFMajid T. Fard
Majid T. Fard
JiangBiao HeJiangBiao He
JiangBiao He
LWLulu Wei
Lulu Wei
RIReza Ilka
Reza Ilka
BMBehrooz Mirafzal
Behrooz Mirafzal
FFFariba Fateh
Fariba Fateh
While wide bandgap (WBG) switches have revolutionized power electronics and motor-drive systems, the high $dv/dt$ associated with these fast-switching semiconductors can easily induce reflected high-frequency overvoltage spikes on motor stator terminals. The shorter rise time of the voltage pulses confines the cable length between the inverter and the motor in practice to avoid overvoltage across the motor stator windings. Even with shorter cables, voltage spikes from variable-speed drives can still cause premature insulation failure and reduce the remaining useful lifetime of the motors. While effective, conventional methods such as $dv/dt$ passive filters or active gate drivers are usually bulky and/or inefficient. To address this problem, an overvoltage mitigation solution, named “Smart Coil”, is introduced in this paper. The smart coil circuit is installed in parallel with the first coil of each motor phase, which typically experiences the highest reflected overvoltage. Upon detection of overvoltage, the proposed ultra-compact smart coil circuit, located at the motor junction box, is activated to limit voltage stress across the coils. Since the smart coil is connected in parallel with the first coil, it only needs to process very low pulsed power during the overvoltage transients. Therefore, it has high efficiency and an ultra-compact footprint while effectively mitigating voltage spikes. The proposed smart coil circuit can be easily scaled for various motor-drive systems regardless of the cable length or rise time of the switching devices. Simulation and experimental test results are provided to verify the effectiveness of the proposed method.