Emre Şeker

Emre Şeker

Auto-generated profile, based on publicly available information

Emre Şeker

Department of Prosthodontics, Faculty of Dentistry, Eskisehir Osmangazi University, Eskisehir, Turkey

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
TÖTuncer Özçelik
Tuncer Özçelik
BYBurak Yilmaz
Burak Yilmaz
EŞEmre Şeker
Emre Şeker
KSKarnik Shah
Karnik Shah
Tuncer Burak ?z?elik, DDS, PhD/Burak Yilmaz, DDS, PhD/Emre Şeker, DDS, PhD/Karnik Shah, BDS, MS: Purpose: The ideal digital cement space value for the fabrication of provisional computer-aided design/computer-aided manufacturing (CAD/CAM) crowns with clinically acceptable marginal adaptation is not well known. The aim of this study was to evaluate the effect of different simulated cement space settings on the marginal fit of poly(methyl methacrylate) (PMMA) provisional CAD/CAM restorations. Materials and Methods: An extracted premolar tooth was prepared using ceramic crown preparation guidelines and represented both natural teeth and/or custom implant abutments. The prepared tooth abutment was scanned with a three-dimensional (3D) laboratory scanner (D900, 3Shape). CAD design software was used to subsequently design a premolar crown core with three different simulated cement space settings (20 to 40 μm, 20 to 50 μm, 20 to 60 μm). PMMA blocks were used to mill the specimens (n = 9, N = 27). Using a stereo zoom microscope, a total of 36 images for each of the 3 groups (9 crowns per group, 4 sites per crown) were captured to measure the mean vertical marginal discrepancy for every group. One-way analysis of variance (ANOVA) was used to analyze the data, and the post hoc Tukey multiple comparison test was performed. Results: The marginal gap values of the PMMA cores fabricated using the three cement space settings were significantly different from each other (P < .001). The marginal gap was smaller with a 20- to 60-μm setting compared with 20 to 50 μm and 20 to 40 μm, and the 20- to 50-μm setting allowed for smaller marginal gaps compared with 20 to 40 μm (P < .001). Conclusion: Within the limitations of this study, the marginal gaps of CAD/CAM-fabricated PMMA cores were smaller when the cement space was larger. The smallest marginal gaps were achieved when a 20- to 60-μm cement space was used (P < .001).

1 February 2019 in Biomedical Journal
Verified
Journal Article
Open access
CÖCaner Öztürk
Caner Öztürk
SPSerdar Polat
Serdar Polat
MTMakbule Tunçdemir
Makbule Tunçdemir
FGFehmi Gönüldaş
Fehmi Gönüldaş
EŞEmre Şeker
Emre Şeker
Restoration of the teeth with extensive root canals with different post systems is a challenge for clinicians. Evaluation of these systems is important for clinical success. The aim of this study was to compare the fracture resistance and fracture mode of endodontically treated thin-walled teeth which restored with different post systems. Eighty extracted and endodontically treated maxillary canines were divided into 4 groups (n = 20) and the thickness of the radicular dentin walls was reduced by using diamond burs. Each root was embedded in an autopolymerizing resin with a 0.25 mm layer of vinyl polysiloxane material to simulate the periodontal ligament. The subgroups were restored with one of the following post systems: only composite resin (Group 1), cast post (Group 2), glass-fiber post (Group 3), and I-TFC post (Group 4). The samples were subjected to a gradually increasing force (0,5 mm/min). The force required to fracture was recorded, and the data were analyzed with ANOVA, Tukey test's and Chi-Square test (p < 0.05). The highest fracture resistance was recorded for Group 2, followed by the Group 3, Group 4, and Group 1. Differences in the fracture resistance of teeth were significant among the groups (p < 0.05). The fracture resistance of Group 4 was significantly different than the other tested post systems (p < 0.05). The lowest fracture resistance was recorded for Group 1, but among all post systems, Group 4 had the lowest fracture resistance. The fracture mode of the fiber posts (Radix and I-TFC posts) would permit repair of the tooth.

1 January 2015 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
ESEmre Seker
Emre Seker
MKMehmet Ali Kılıçarslan
Mehmet Ali Kılıçarslan
SDSule Tugba Deniz
Sule Tugba Deniz
EMEmre Mumcu
Emre Mumcu
POPelin Ozkan
Pelin Ozkan
Seker E, et al. J Adv Prosthodont. 2015 Jun;7(3):249-256. https://doi.org/10.4047/jap.2015.7.3.249

1 January 2014 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
EŞEmre Şeker
Emre Şeker
MUMutahhar Ulusoy
Mutahhar Ulusoy
OOOğuz Ozan
Oğuz Ozan
DDDerya Özdemir Doğan
Derya Özdemir Doğan
BKBasak Kusakci-Seker
Basak Kusakci-Seker
Emre Şeker, DDS, PhD/Mutahhar Ulusoy, DDS, PhD/Oğuz Ozan, DDS, PhD/Derya ?zdemir Doğan, DDS, PhD/Başak Kuşakci Şeker, DDS, PhD : Purpose: The purpose of this study was to analyze the functional stresses around implants and supporting tissues placed in different combinations in the grafted and nongrafted atrophic posterior maxilla and to consider the acceptability of various fixed partial denture treatment options. Materials and Methods: A computer model of the atrophic posterior maxilla was created from the computed tomography images of an actual patient. Three different treatment scenarios were modeled with partial denture restorations, grafted and nongrafted maxillary sinuses, and various implant inclinations. Oblique forces were applied to simulate chewing movements. Stress analyses were performed with a three-dimensional finite element analysis computer program, and the von Mises and minimum principal stresses on the implants and supporting tissues were compared. Results: In all models, minimum principal (compressive) stress peak points were the highest within the crestal cortical bone (49.761 MPa), lower within sinus cortical (14.144 MPa) and trabecular bone (4.347 MPa), and lowest within grafted bone (0.049 MPa). The second molar implant in the third model (5 ? 11-mm implant, inclined 45 degrees) showed the highest von Mises stresses (499.50 MPa), and the second molar implant in the first model (6 ? 5-mm implant) showed the lowest (219.63 MPa) von Mises stresses. Conclusion: The stress absorption capacity of graft material is not sufficient and is much lower than that of other supporting tissues. For a fixed partial prosthesis, the use of short, wide implants with sinus floor bicortical fixation was found to be the most feasible approach for the atrophied posterior maxilla.

1 April 2016 in Plasma Science and Technology
Verified
Journal Article
Closed access
PDF file
ESEmre Seker
Emre Seker
MKMehmet Ali Kılıçarslan
Mehmet Ali Kılıçarslan
SPSerdar Polat
Serdar Polat
EOEmre Ozkir
Emre Ozkir
SPSuat Pat
Suat Pat

9 September 2020 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
BKBasak Kusakci-Seker
Basak Kusakci-Seker
KOKaan Orhan
Kaan Orhan
EŞEmre Şeker
Emre Şeker
GUGülbahar USTAOĞLU
Gülbahar USTAOĞLU
OOOğuz Ozan
Oğuz Ozan
NBNilsun BAGIS
Nilsun BAGIS
Background: Alveolar bone height in the posterior maxillary region is very important and critical for dental implant planning and placement. Objective: This study aimed to evaluate the anatomy of the maxillary sinus floor in relation to the alveolar crest and to determine variations in the vertical measurements between the maxillary sinus floor and the alveolar bone crest tip in the posterior edentulous maxilla with the use of cone beam computerized tomography. Methods: This analysis enrolled 234 retrospectively selected patients (123 males with mean age 52.95±11.74 (range 32-76 years) and 111 females with mean age 58.14±11.92 (range 32-75 years)) with edentulous posterior maxillary regions. The maxillary sinus floor was divided into three anatomical segments (anterior, median and posterior) in relation to the transverse palatine suture. The measurements were performed on 3D surface rendered volumetric images by using rotation and translation of the views. Landmarks for measurement were specified by using a cursor driven pointer. Vertical lines were marked on the cross-sectional images between the alveolar ridge and the deepest point of the maxillary sinus floor for each of the three regions. P < 0.05 was regarded as statistically significant. Results: The mean distance values between the sinus floor and the alveolar crest in the anterior, median and posterior regions were 8.74±3.97 mm, 5.37±3.23 mm and 7.06±3.28 mm, respectively. Measurements in the anterior region were found to be high in both total and gender groups compared to other regions. Also, subsinus alveolar bone heights decreased with increasing age in both genders in all three regions. Conclusion: This study emphasizes that the mean subsinus alveolar bone height is highest in the anterior segment of the edentulous posterior maxilla. These results may guide clinicians to make the decision of implant placement area and lead to less invasive alternative surgery methods for edentulous posterior segments.