Tuncer Burak Ozcelik

Tuncer Burak Ozcelik

Auto-generated profile, based on publicly available information

Tuncer Burak Ozcelik

Burak Ozcelik Professor, Baskent University Faculty of Dentistry Department of Prosthodontics, Ankara, Turkey

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
TÖTuncer Özçelik
Tuncer Özçelik
BYBurak Yilmaz
Burak Yilmaz
EŞEmre Şeker
Emre Şeker
KSKarnik Shah
Karnik Shah
Tuncer Burak ?z?elik, DDS, PhD/Burak Yilmaz, DDS, PhD/Emre Şeker, DDS, PhD/Karnik Shah, BDS, MS: Purpose: The ideal digital cement space value for the fabrication of provisional computer-aided design/computer-aided manufacturing (CAD/CAM) crowns with clinically acceptable marginal adaptation is not well known. The aim of this study was to evaluate the effect of different simulated cement space settings on the marginal fit of poly(methyl methacrylate) (PMMA) provisional CAD/CAM restorations. Materials and Methods: An extracted premolar tooth was prepared using ceramic crown preparation guidelines and represented both natural teeth and/or custom implant abutments. The prepared tooth abutment was scanned with a three-dimensional (3D) laboratory scanner (D900, 3Shape). CAD design software was used to subsequently design a premolar crown core with three different simulated cement space settings (20 to 40 μm, 20 to 50 μm, 20 to 60 μm). PMMA blocks were used to mill the specimens (n = 9, N = 27). Using a stereo zoom microscope, a total of 36 images for each of the 3 groups (9 crowns per group, 4 sites per crown) were captured to measure the mean vertical marginal discrepancy for every group. One-way analysis of variance (ANOVA) was used to analyze the data, and the post hoc Tukey multiple comparison test was performed. Results: The marginal gap values of the PMMA cores fabricated using the three cement space settings were significantly different from each other (P < .001). The marginal gap was smaller with a 20- to 60-μm setting compared with 20 to 50 μm and 20 to 40 μm, and the 20- to 50-μm setting allowed for smaller marginal gaps compared with 20 to 40 μm (P < .001). Conclusion: Within the limitations of this study, the marginal gaps of CAD/CAM-fabricated PMMA cores were smaller when the cement space was larger. The smallest marginal gaps were achieved when a 20- to 60-μm cement space was used (P < .001).

14 March 2007 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
TÖTuncerBurak Özçelik
TuncerBurak Özçelik
TBTuncer Burak
Tuncer Burak
AEAhmet Ersan Ersoy
Ahmet Ersan Ersoy

1 October 2021 in Journal of Dentistry
Verified
Journal Article
Open access
SASamir Abou-Ayash
Samir Abou-Ayash
MSMartin Schimmel
Martin Schimmel
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
BOBurak Ozcelik
Burak Ozcelik
UBUrs Brägger
Urs Brägger
BYBurak Yilmaz
Burak Yilmaz
To investigate the trueness and marginal fit of computer-aided design-computer-aided manufactured (CAD-CAM) complete-arch implant-supported screw-retained fixed prosthesis (CAISFP) made of polyetheretherketone (PEEK), polyetherketoneketone (PEKK) and titanium (Ti) MATERIAL AND METHODS: A typodont model with four implants, their multiunit abutments (MUAs), and MUA scanbodies were digitized by using a laboratory scanner. The generated CAD was used to mill CAISFP frameworks in Ti, PEEK, or PEKK (each n = 10). The frameworks were digitized with an industrial light scanner to superimpose resulting standard tessellation language (STL) file with the CAD file. Deviations at five points at the abutment-framework interface of each of the four abutment sites (1:left first molar, 2:left canine, 3:right canine, 4:right first molar sites) were calculated (trueness). Marginal gaps were measured using the triple scan technique. A nonparametric repeated measures ANOVA by Brunner and Puri with factors being abutment location and material was performed to assess the mean deviations for trueness and mean marginal gaps, followed by Mann-Whitney or exact Wilcoxon Signed-Rank tests (alpha=.05). Material type significantly affected the trueness (p<0.0001). PEEK had the lowest deviations (0.039 +/-0.01mm) followed by PEKK (0,049 +/-0.009mm), and Ti (0.074 +/-0.011mm). For marginal gaps, only abutment location's effect was significant (p = 0.003). Within PEKK, gaps at abutment 4 were significantly larger, compared with abutments 2 (p = 0.04) and 3 (p = 0.02). The trueness of PEEK, PEKK, and Ti frameworks was different after milled. PEEK had the highest trueness. However, the marginal fit of the frameworks was similar and smaller than 90 µm in average. PEEK, PEKK, and Ti complete-arch frameworks had clinically acceptable gaps and may therefore be recommended when their fit is considered. Higher trueness after milling did not result in better marginal fit.

1 May 2020 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
EKEdiz Kale
Ediz Kale
MCMesutcan Cilli
Mesutcan Cilli
TÖTuncer Burak Özçelik
Tuncer Burak Özçelik
BYBurak Yilmaz
Burak Yilmaz

1 April 2010 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
TÖTuncer Burak Özçelik
Tuncer Burak Özçelik
PTPaul Benjamin Tanner
Paul Benjamin Tanner

1 February 2008 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
TOTuncer Burak Ozcelik
Tuncer Burak Ozcelik
ZPZafer Ozgur Pektas
Zafer Ozgur Pektas