Thierry Buchillier

Thierry Buchillier

Auto-generated profile, based on publicly available information

Thierry Buchillier

Inst Radiat Phys, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Open access
FJFrederic Juget
Frederic Juget
ZTZeynep Talip
Zeynep Talip
TBThierry Buchillier
Thierry Buchillier
MDM. Teresa Durán
M. Teresa Durán
YNYoucef Nedjadi
Youcef Nedjadi
CBClaude Bailat
Claude Bailat
In this study, the gamma and X-ray emission intensities of 161Tb were determined using a high-purity germanium spectrometer. The samples used were previously standardised by coincidence counting and Triple to Double Coincidence Ratio (TDCR) methods. A total of 28 gamma-rays and 4 X-rays were measured and compared with previous measurements performed more than 30 years ago. Most of the lines are in agreement, while large discrepancies are observed for 5 lines. The uncertainties have been dramatically decreased with respect to previous measurements giving a better knowledge of the 161 Tb day.

1 October 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Open access
ZTZeynep Talip
Zeynep Talip
FJFrédéric Juget
Frédéric Juget
JUJiri Ulrich
Jiri Ulrich
YNYoucef Nedjadi
Youcef Nedjadi
TBThierry Buchillier
Thierry Buchillier
NMNick Van der Meulen
Nick Van der Meulen
The gamma and X-ray emission intensities of Er-169 were determined using radionuclidically pure Er-169. The activity of the Er-169 source was standardized by the triple-to-double-coincidence ratio technique. Three independent measurements were performed to measure the emission intensities using calibrated high-purity germanium spectrometers. The efficiencies were computed with the Monte Carlo method and validated using several experimental measurements. Final results present a large uncertainty reduction compared to previous evaluations. The emission intensities per decay of Er-169 are reported as 1.401(40).10(-5) for the 109.8 keV line and 1.513(19).10(-6) for the 118.2 keV line. The values obtained for the X-ray lines show large discrepancies with the reference values.

1 August 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Open access
YNYoucef Nedjadi
Youcef Nedjadi
LDLaurent Desoirgher
Laurent Desoirgher
FJFrédéric Juget
Frédéric Juget
TBThierry Buchillier
Thierry Buchillier
FBFrançois Bochud
François Bochud
CBClaude Bailat
Claude Bailat
We report here on the primary activity standardisation of a223Ra dichloride solution in equilibrium with its decay daughters. Both the triple-to-double-coincidence-ratio (TDCR) method with an in-house TDCR detector and the CIEMAT-NIST efficiency tracing (CNET) technique with a commercial counter were used. The liquid scintillation efficiencies for both methods are about 6 while the activities they predict with about 0.4% relative standard uncertainty agree within 0.15%. For backup, the solution was also standardised with 4πγ NaI(Tl) integral counting with a well-type NaI(Tl) detector, and efficiencies computed by Monte Carlo simulations using the GEANT code. This simple technique, unused previously for this nuclide, yielded an activity concentration compatible with, but 1% lower than, the one determined by liquid scintillation counting.

25 February 2022 in Physica Medica
Verified
Journal Article
Closed access
CBC. Bailat
C. Bailat
PGP. Jorge Goncalves
P. Jorge Goncalves
VGV. Grilj
V. Grilj
TBT. Buchillier
T. Buchillier
MGM. Gondré
M. Gondré
RMRaphaël Moeckli
Raphaël Moeckli