Luca Cerny Oliveira

Luca Cerny Oliveira

Auto-generated profile, based on publicly available information

Luca Cerny Oliveira

Department of Electrical and Computer Engineering, University of California Davis , Davis, CA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
HSHeather Siefkes
Heather Siefkes
LOLuca Cerny Oliveira
Luca Cerny Oliveira
RKRobert Koppel
Robert Koppel
WHWhitnee Hogan
Whitnee Hogan
MGMeena Garg
Meena Garg
CCChen‐Nee Chuah
Chen‐Nee Chuah
Background: Oxygen saturation (Sp o 2 ) screening has not led to earlier detection of critical congenital heart disease (CCHD). Adding pulse oximetry features (ie, perfusion data and radiofemoral pulse delay) may improve CCHD detection, especially coarctation of the aorta (CoA). We developed and tested a machine learning (ML) pulse oximetry algorithm to enhance CCHD detection. Methods and Results: Six sites prospectively enrolled newborns with and without CCHD and recorded simultaneous pre‐ and postductal pulse oximetry. We focused on models at 1 versus 2 time points and with/without pulse delay for our ML algorithms. The sensitivity, specificity, and area under the receiver operating characteristic curve were compared between the Sp o 2 ‐alone and ML algorithms. A total of 523 newborns were enrolled (no CHD, 317; CHD, 74; CCHD, 132, of whom 21 had isolated CoA). When applying the Sp o 2 ‐alone algorithm to all patients, 26.2% of CCHD would be missed. We narrowed the sample to patients with both 2 time point measurements and pulse‐delay data (no CHD, 65; CCHD, 14) to compare ML performance. Among these patients, sensitivity for CCHD detection increased with both the addition of pulse delay and a second time point. All ML models had 100% specificity. With a 2‐time‐points+pulse‐delay model, CCHD sensitivity increased to 92.86% ( P =0.25) compared with Sp o 2 alone (71.43%), and CoA increased to 66.67% ( P =0.5) from 0. The area under the receiver operating characteristic curve for CCHD and CoA detection significantly improved (0.96 versus 0.83 for CCHD, 0.83 versus 0.48 for CoA; both P =0.03) using the 2‐time‐points+pulse‐delay model compared with Sp o 2 alone. Conclusions: ML pulse oximetry that combines oxygenation, perfusion data, and pulse delay at 2 time points may improve detection of CCHD and CoA within 48 hours after birth. Registration: URL: https://www.clinicaltrials.gov/study/NCT04056104?term=NCT04056104&rank=1 ; Unique identifier: NCT04056104.

26 December 2024 in Journal of Neuropathology & Experimental Neurology
Verified
Journal Article
Open access
LOLuca Cerny Oliveira
Luca Cerny Oliveira
JCJoohi Chauhan
Joohi Chauhan
ACAjinkya Chaudhari
Ajinkya Chaudhari
SCSen-Ching S Cheung
Sen-Ching S Cheung
VPViharkumar Patel
Viharkumar Patel
BDBrittany N Dugger
Brittany N Dugger
Microinfarcts and microhemorrhages are characteristic lesions of cerebrovascular disease. Although multiple studies have been published, there is no one universal standard criteria for the neuropathological assessment of cerebrovascular disease. In this study, we propose a novel application of machine learning in the automated screening of microinfarcts and microhemorrhages. Utilizing whole slide images (WSIs) from postmortem human brain samples, we adapted a patch-based pipeline with convolutional neural networks. Our cohort consisted of 22 cases from the University of California Davis Alzheimer’s Disease Research Center brain bank with hematoxylin and eosin-stained formalin-fixed, paraffin-embedded sections across 3 anatomical areas: frontal, parietal, and occipital lobes (40 WSIs with microinfarcts and/or microhemorrhages, 26 without). We propose a multiple field-of-view prediction step to mitigate false positives. We report screening performance (ie, the ability to distinguish microinfarct/microhemorrhage-positive from microinfarct/microhemorrhage-negative WSIs), and detection performance (ie, the ability to localize the affected regions within a WSI). Our proposed approach improved detection precision and screening accuracy by reducing false positives thereby achieving 100% screening accuracy. Although this sample size is small, this pipeline provides a proof-of-concept for high efficacy in screening for characteristic brain changes of cerebrovascular disease to aid in screening of microinfarcts/microhemorrhages at the WSI level.