18 June 2024 in Journal of the American Heart Association
Background: Oxygen saturation (Sp o 2 ) screening has not led to earlier detection of critical congenital heart disease (CCHD). Adding pulse oximetry features (ie, perfusion data and radiofemoral pulse delay) may improve CCHD detection, especially coarctation of the aorta (CoA). We developed and tested a machine learning (ML) pulse oximetry algorithm to enhance CCHD detection. Methods and Results: Six sites prospectively enrolled newborns with and without CCHD and recorded simultaneous pre‐ and postductal pulse oximetry. We focused on models at 1 versus 2 time points and with/without pulse delay for our ML algorithms. The sensitivity, specificity, and area under the receiver operating characteristic curve were compared between the Sp o 2 ‐alone and ML algorithms. A total of 523 newborns were enrolled (no CHD, 317; CHD, 74; CCHD, 132, of whom 21 had isolated CoA). When applying the Sp o 2 ‐alone algorithm to all patients, 26.2% of CCHD would be missed. We narrowed the sample to patients with both 2 time point measurements and pulse‐delay data (no CHD, 65; CCHD, 14) to compare ML performance. Among these patients, sensitivity for CCHD detection increased with both the addition of pulse delay and a second time point. All ML models had 100% specificity. With a 2‐time‐points+pulse‐delay model, CCHD sensitivity increased to 92.86% ( P =0.25) compared with Sp o 2 alone (71.43%), and CoA increased to 66.67% ( P =0.5) from 0. The area under the receiver operating characteristic curve for CCHD and CoA detection significantly improved (0.96 versus 0.83 for CCHD, 0.83 versus 0.48 for CoA; both P =0.03) using the 2‐time‐points+pulse‐delay model compared with Sp o 2 alone. Conclusions: ML pulse oximetry that combines oxygenation, perfusion data, and pulse delay at 2 time points may improve detection of CCHD and CoA within 48 hours after birth. Registration: URL: https://www.clinicaltrials.gov/study/NCT04056104?term=NCT04056104&rank=1 ; Unique identifier: NCT04056104.
24 August 2026 in SSRN Electronic Journal
Objectives: Patent ductus arteriosus (PDA) is the most common cardiovascular finding in preterm neonates, yet assessment of hemodynamic significance relies on echocardiography, which is intrusive and provides only single-point-in-time data. Photoplethysmography (PPG) may offer a continuous, non-invasive alternative. We quantified changes in automated PPG indices—pulse transit time in the hand and foot (PTT-h, PTT-f), foot-to-hand time delay (f-hTD), and relative pulse amplitude in the hand and foot (rAM-h, rAM-f)—following transcatheter PDA closure (TCPC) in preterm infants and correlated these changes with echocardiographic stroke volume.Study Design: A prospective, single-center cohort study was conducted in a Level IV NICU (January 2022–March 2024). Very low birth weight infants (<1500 g) with hemodynamically significant PDA scheduled for TCPC were enrolled. PPG waveforms were recorded using standard pulse oximeter probes connected to a custom device that automatically calculated indices from 20-pulse sequences. Recordings and echocardiograms were obtained before and 24–48 hours after TCPC.Results: Eighteen infants were enrolled (median gestational age 25.2 weeks; birth weight 755 g). Stroke volume decreased significantly after TCPC (3.56 vs. 2.58 mL, p=0.042). PTT-h increased from 32 to 48 msec (p3 mL) with 89% sensitivity and 80% specificity.Conclusions: PPG indices change significantly after TCPC, and PTT-h correlates well with SV. PPG may complement echocardiography in assessing PDA hemodynamic significance.