Gregory Scott Fischer

Gregory Scott Fischer

Auto-generated profile, based on publicly available information

Gregory Scott Fischer

Worcester Polytechnic Institute

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014
Verified
Conference Paper
Closed access
PKPeter Kazanzides
Peter Kazanzides
ZCZihan Chen
Zihan Chen
ADAnton Deguet
Anton Deguet
GFGregory S. Fischer
Gregory S. Fischer
RTRussell H. Taylor
Russell H. Taylor
SDSimon P. DiMaio
Simon P. DiMaio
We present a telerobotics research platform that provides complete access to all levels of control via open-source electronics and software. The electronics employs an FPGA to enable a centralized computation and distributed I/O architecture in which all control computations are implemented in a familiar development environment (Linux PC) and low-latency I/O is performed over an IEEE-1394a (FireWire) bus at speeds up to 400 Mbits/sec. The mechanical components are obtained from retired first-generation da Vinci ® Surgical Systems. This system is currently installed at 11 research institutions, with additional installations underway, thereby creating a research community around a common open-source hardware and software platform.

20 July 2009 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
JTJunichi Tokuda
Junichi Tokuda
GFGregory S. Fischer
Gregory S. Fischer
XPXenophon Papademetris
Xenophon Papademetris
ZYZiv Yaniv
Ziv Yaniv
LILuis Ibanez
Luis Ibanez
NHNobuhiko Hata
Nobuhiko Hata

13 June 2008 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
GFGregory S. Fischer
Gregory S. Fischer
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
CCCsaba Csoma
Csaba Csoma
JTJunichi Tokuda
Junichi Tokuda
SDSimon P. DiMaio
Simon P. DiMaio
GFGabor Fichtinger
Gabor Fichtinger
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

11 February 2016 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CNChristopher J. Nycz
Christopher J. Nycz
TBTobias Butzer
Tobias Butzer
OLOlivier Lambercy
Olivier Lambercy
JAJumpei Arata
Jumpei Arata
GFGregory S. Fischer
Gregory S. Fischer
RGRoger Gassert
Roger Gassert
Enabling individuals who are living with reduced mobility of the hand to utilize portable exoskeletons at home has the potential to deliver rehabilitation therapies with a greater intensity and relevance to activities of daily living. Various hand exoskeleton designs have been explored in the past, however, devices have remained nonportable and cumbersome for the intended users. Here we investigate a remote actuation system for wearable hand exoskeletons, which moves weight from the weakened limb to the shoulders, reducing the burden on the user and improving portability. A push-pull Bowden cable was used to transmit actuator forces from a backpack to the hand with strict attention paid to total system weight, size, and the needs of the target population. We present the design and integration of this system into a previously presented hand exoskeleton, as well as its characterization. Integration of remote actuation reduced the exoskeleton weight by 56% to 113g without adverse effects to functionality. Total actuation system weight was kept to 754g. The loss of positional accuracy inherent with Bowden cable transmissions was compensated for through closed loop positional control of the transmission output. The achieved weight reduction makes hand exoskeletons more suitable to the intended user, which will permit the study of their effectiveness in providing long duration, high intensity, and targeted rehabilitation as well as functional assistance.

3 May 2022 in Proceedings of the IEEE
Verified
Journal Article
Open access
Hao SuHao Su
Hao Su
Ka Wai KwokKa Wai Kwok
Ka Wai Kwok
KCKevin Cleary
Kevin Cleary
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MCM. Cenk Cavusoglu
M. Cenk Cavusoglu
GFGregory S. Fischer
Gregory S. Fischer
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.

4 November 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GLGang Li
Gang Li
Hao SuHao Su
Hao Su
GCGregory A. Cole
Gregory A. Cole
WSWeijian Shang
Weijian Shang
KHKevin Harrington
Kevin Harrington
GFGregory S. Fischer
Gregory S. Fischer
Stereotaxy is a neurosurgical technique that can take several hours to reach a specific target, typically utilizing a mechanical frame and guided by preoperative imaging. An error in any one of the numerous steps or deviations of the target anatomy from the preoperative plan such as brain shift (up to 20 mm), may affect the targeting accuracy and thus the treatment effectiveness. Moreover, because the procedure is typically performed through a small burr hole opening in the skull that prevents tissue visualization, the intervention is basically “blind” for the operator with limited means of intraoperative confirmation that may result in reduced accuracy and safety. The presented system is intended to address the clinical needs for enhanced efficiency, accuracy, and safety of image-guided stereotactic neurosurgery for deep brain stimulation lead placement. The study describes a magnetic resonance imaging (MRI)-guided, robotically actuated stereotactic neural intervention system for deep brain stimulation procedure, which offers the potential of reducing procedure duration while improving targeting accuracy and enhancing safety. This is achieved through simultaneous robotic manipulation of the instrument and interactively updated in situ MRI guidance that enables visualization of the anatomy and interventional instrument. During simultaneous actuation and imaging, the system has demonstrated less than 15% signal-to-noise ratio variation and less than 0.20% geometric distortion artifact without affecting the imaging usability to visualize and guide the procedure. Optical tracking and MRI phantom experiments streamline the clinical workflow of the prototype system, corroborating targeting accuracy with three-axis root mean square error 1.38 ± 0.45 mm in tip position and 2.03 ± 0.58° in insertion angle.