Hao Su

Dr. Hao Su

Irwin Zahn Endowed Assistant Professor, Department of Mechanical Engineering, City University of New York, City College, New York, NY, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
Yichao TangYichao Tang
Yichao Tang
YCYinding Chi
Yinding Chi
JSJiefeng Sun
Jiefeng Sun
THTzu-Hao Huang
Tzu-Hao Huang
OMOmid H. Maghsoudi
Omid H. Maghsoudi
JYJie Yin
Jie Yin
Soft machines typically exhibit slow locomotion speed and low manipulation strength because of intrinsic limitations of soft materials. Here, we present a generic design principle that harnesses mechanical instability for a variety of spine-inspired fast and strong soft machines. Unlike most current soft robots that are designed as inherently and unimodally stable, our design leverages tunable snap-through bistability to fully explore the ability of soft robots to rapidly store and release energy within tens of milliseconds. We demonstrate this generic design principle with three high-performance soft machines: High-speed cheetah-like galloping crawlers with locomotion speeds of 2.68 body length/s, high-speed underwater swimmers (0.78 body length/s), and tunable low-to-high-force soft grippers with over 1 to 103 stiffness modulation (maximum load capacity is 11.4 kg). Our study establishes a new generic design paradigm of next-generation high-performance soft robots that are applicable for multifunctionality, different actuation methods, and materials at multiscales.

12 June 2024 in Nature
Verified
Journal Article
Closed access
PDF file
SLShuzhen Luo
Shuzhen Luo
MJMenghan Jiang
Menghan Jiang
SZSainan Zhang
Sainan Zhang
JZJunxi Zhu
Junxi Zhu
SYShuangyue Yu
Shuangyue Yu
Hao SuHao Su
Hao Su

18 May 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
SYShuangyue Yu
Shuangyue Yu
THTzu-Hao Huang
Tzu-Hao Huang
XYXiaolong Yang
Xiaolong Yang
CJChunhai Jiao
Chunhai Jiao
JYJianfu Yang
Jianfu Yang
Hao SuHao Su
Hao Su
High-performance actuators are crucial to enable mechanical versatility of wearable robots, which are required to be lightweight, highly backdrivable, and with high bandwidth. State-of-the-art actuators, e.g., series elastic actuators, have to compromise bandwidth to improve compliance (i.e., backdrivability). In this article, we describe the design and human-robot interaction modeling of a portable hip exoskeleton based on our custom quasi-direct drive actuation (i.e., a high torque density motor with low ratio gear). We also present a model-based performance benchmark comparison of representative actuators in terms of torque capability, control bandwidth, backdrivability, and force tracking accuracy. This article aims to corroborate the underlying philosophy of “design for control,” namely meticulous robot design can simplify control algorithms while ensuring high performance. Following this idea, we create a lightweight bilateral hip exoskeleton to reduce joint loadings during normal activities, including walking and squatting. Experiments indicate that the exoskeleton is able to produce high nominal torque (17.5 Nm), high backdrivability (0.4 Nm backdrive torque), high bandwidth (62.4 Hz), and high control accuracy (1.09 Nm root mean square tracking error, 5.4% of the desired peak torque). Its controller is versatile to assist walking at different speeds and squatting. This article demonstrates performance improvement compared with state-of-the-art exoskeletons.

3 May 2022 in Proceedings of the IEEE
Verified
Journal Article
Open access
Hao SuHao Su
Hao Su
Ka Wai KwokKa Wai Kwok
Ka Wai Kwok
KCKevin Cleary
Kevin Cleary
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MCM. Cenk Cavusoglu
M. Cenk Cavusoglu
GFGregory S. Fischer
Gregory S. Fischer
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.

4 November 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GLGang Li
Gang Li
Hao SuHao Su
Hao Su
GCGregory A. Cole
Gregory A. Cole
WSWeijian Shang
Weijian Shang
KHKevin Harrington
Kevin Harrington
GFGregory S. Fischer
Gregory S. Fischer
Stereotaxy is a neurosurgical technique that can take several hours to reach a specific target, typically utilizing a mechanical frame and guided by preoperative imaging. An error in any one of the numerous steps or deviations of the target anatomy from the preoperative plan such as brain shift (up to 20 mm), may affect the targeting accuracy and thus the treatment effectiveness. Moreover, because the procedure is typically performed through a small burr hole opening in the skull that prevents tissue visualization, the intervention is basically “blind” for the operator with limited means of intraoperative confirmation that may result in reduced accuracy and safety. The presented system is intended to address the clinical needs for enhanced efficiency, accuracy, and safety of image-guided stereotactic neurosurgery for deep brain stimulation lead placement. The study describes a magnetic resonance imaging (MRI)-guided, robotically actuated stereotactic neural intervention system for deep brain stimulation procedure, which offers the potential of reducing procedure duration while improving targeting accuracy and enhancing safety. This is achieved through simultaneous robotic manipulation of the instrument and interactively updated in situ MRI guidance that enables visualization of the anatomy and interventional instrument. During simultaneous actuation and imaging, the system has demonstrated less than 15% signal-to-noise ratio variation and less than 0.20% geometric distortion artifact without affecting the imaging usability to visualize and guide the procedure. Optical tracking and MRI phantom experiments streamline the clinical workflow of the prototype system, corroborating targeting accuracy with three-axis root mean square error 1.38 ± 0.45 mm in tip position and 2.03 ± 0.58° in insertion angle.

5 November 2014 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
Hao SuHao Su
Hao Su
WSWeijian Shang
Weijian Shang
GCGregory Cole
Gregory Cole
GLGang Li
Gang Li
KHKevin Harrington
Kevin Harrington
GFGregory S. Fischer
Gregory S. Fischer
This paper presents a fully actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intraoperative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-T MRI scanner using standard imaging sequences and the signal-to-noise ratio loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87-mm root-mean-square (RMS) error in 3-D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure.