Raj Kumar Jarial

Raj Kumar Jarial

Auto-generated profile, based on publicly available information

Raj Kumar Jarial

NIT Hamirpur

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2008 in IEEE Electrical Insulation Magazine
Verified
Journal Article
Closed access
JSJashandeep Singh
Jashandeep Singh
YSYog Raj Sood
Yog Raj Sood
RJRaj Kumar Jarial
Raj Kumar Jarial

25 February 2016 in IEEE Electrical Insulation Magazine
Verified
Journal Article
Closed access
URU. Mohan Rao
U. Mohan Rao
YSYog Raj Sood
Yog Raj Sood
RJRaj Kumar Jarial
Raj Kumar Jarial
Mineral oils have been used in transformers for cooling and insulation for many years. Despite their long-time success, mineral oils are facing critiques by the electrical power industry in terms of thermal performance-mineral oils have relatively low flashpoint and fire point and will burn in the event of a fault [1], [2], [3]; environmental performance-mineral oils are less biodegradable, toxic in nature, and hazardous in the soil and water [4]; and risk assessment-mineral oils are imperilling near hospitals, near high rise buildings, and in residential areas. In this search, it has been reported that ester-based dielectric oils are a good replacement for mineral insulating oils, exceeding all of the technical demerits of mineral oils, and can operate at higher temperatures [5]-[8]. Nevertheless, the cost of these ester-based oils is comparatively higher than mineral oils [9], resulting in diminished interest in the use of these oils as a replacement. With an augmented fire margin, the industry can avoid fire mitigation equipment, deluge systems, and fire walls, and with application of safer technology, the industry can save on burden stashes and high insurance premiums. These benefits far overweight the additional cost invested on ester dielectrics. Moreover, the major drawback of the ester dielectrics is their poor oxidation stability compared with mineral oils [10].

13 June 2016 in IETE Technical Review
Verified
Journal Article
Closed access
MUMOHAN RAO UNGARALA
MOHAN RAO UNGARALA
YSYog Raj Sood
Yog Raj Sood
RJRaj Kumar Jarial
Raj Kumar Jarial
In this paper, evolution of ester dielectrics highlighting the significant contributions towards replacement of mineral oils with ester oils was discussed. The citations listed in this survey provide a representative sample to current scenario pertaining to ester dielectrics in transformer insulation technology. Additionally, X-ray diffraction analysis highlighting the degradation rate of insulation paper in the presence of typical dielectric liquids, UV spectroscopy analysis of oils, interfacial tension variations, and diffusion characteristics of insulation paper were experimentally found by simulating accelerated thermal stresses. Furthermore, future challenges and outlook in accommodating ester dielectric liquids for safer and effective transformer technology were also discussed.

1 January 2015 in Procedia Computer Science
Verified
Journal Article
Open access
URU. Mohan Rao
U. Mohan Rao
YSY.R. Sood
Y.R. Sood
RJR.K. Jarial
R.K. Jarial
Performance of a fuzzy expert system is related with how good the membership functions are normalized, tuned for a problem statement and correlation of antecedents and consequents. This paper helps in tuning and designing the membership functions that are best suited for the problem statement by integrating subtractive clustering method for fuzzy expert system design. Subtractive clustering algorithm is used to generate the tuned membership functions automatically in accordance to the domain knowledge. The proposed integrated design of clustering based fuzzy expert system acts in improving the accuracy and leads to a précised decision making environment. A practical example for ageing assessment of transformer insulation oil has been included to illustrate the method much effectively; the discussed example has been validated practically in the laboratory and is found that the proposed method is efficient in decision making

1 August 2019 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
KCKingshuk Chatterjee
Kingshuk Chatterjee
SDSubham Dawn
Subham Dawn
Vinay Kumar JadounVinay Kumar Jadoun
Vinay Kumar Jadoun
RJR.K. Jarial
R.K. Jarial
Dissolved gas analysis (DGA) is among the most essential techniques for diagnosis of incipient faults in power transformers. Here, a novel graphical DGA technique is proposed in which fault zones are distinguished based on certainty of prediction. The Duval Pentagon 1 and gas ratio combination methods are two most recent techniques with high prediction accuracy. In the Duval Pentagon 1, the rigidly separated distinct fault zones reduce the flexibility of analysis because the fault distributions themselves are not that strictly separated. This also prevents the full utilisation of the information available from the distribution patterns of the graphical representation. This problem has been addressed by overlapping individual fault zones and overlapping them using a multi‐layer perceptron (MLP) network with fuzzy class boundaries. Then, in the regions, where multiple fault zones overlap, a modified gas ratio combination method is applied. Finally, a fuzzy decision‐making system is developed for predicting the fault using information from both graphical distribution and gas ratios. The combined accuracy of the regions of certainty has been found exceptionally high (98.36%) compared to the regions of uncertainty (58.97%), whereas the overall prediction accuracy of the proposed technique is found comparatively higher (83%) than both the existing methods.

2 July 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
APATUL JAYSING PATIL
ATUL JAYSING PATIL
RNRam Naresh
Ram Naresh
RJRaj Kumar Jarial
Raj Kumar Jarial
HMHasmat Malik
Hasmat Malik
Ensuring transformer health and accurate fault diagnosis is crucial for the reliable operation of power systems. Development of data-driven techniques for fault interpretation in mineral oil filled transformers becomes challenging due to limited availability of real-world data. The research investigates on development of a novel optimized synthetic data dataset for three different ML models—K-Nearest Neighbors (KNN), Support Vector Machine (SVM), and Random Forest (RF) that maximizes the accuracy of these data driven algorithms without training with excessive data instances resulting in overfitting on the training dataset. Utilizing a dataset from 1135 diverse transformers for ML model training, the study introduces a novel two-step iterative and optimized methodology for generating a synthetic database. The integration of real and synthetic data enhances the overall efficacy of incipient fault identification using ML algorithms. To ensure robust evaluation and comparison of performance, the IEC TC 10 dataset is employed. With optimized dataset, the accuracy of the KNN model increased from 79.33 % to 90.26 % when the prior was trained only with real-world data. The verification of the generated synthetic data from the proposed method, compared to existing methods, demonstrated its superiority in dataset quality.