Kai Zhou

Kai Zhou

Auto-generated profile, based on publicly available information

Kai Zhou

High Voltage Laboratory, College of Electrical Engineering, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KZKai Zhou
Kai Zhou
YFYao Fu
Yao Fu
Guangya ZhuGuangya Zhu
Guangya Zhu
SZShilin Zhao
Shilin Zhao
LLLu Lu
Lu Lu
SMShiyu Ma
Shiyu Ma
Time domain reflectometry (TDR) is an effective method used to detect partial discharge (PD) and localize PD sources on power cables. However, for long-length power cables, the attenuation and dispersion of PD signals are significant due to the propagated distance. The attenuation causes a serious reduction of the pulse amplitude, which makes the defects located far away from the PD detector difficult to find. The dispersion causes appreciable asymmetry in the PD pulse wave form. Thus, the localization accuracy is reduced. To solve the problem of long-length cable fault localization, a novel signal relay system is proposed in this paper. Once a weak PD pulse is captured in the signal relay system, another standard Gaussian pulse signal is initiated by a function generator. The Gaussian pulse signal is injected into the cable and travels along the cable. During this procedure, the weak PD pulse is likely to be amplified, and the fault localization accuracy is notably enhanced. To validate the effectiveness of the proposed method, an experimental platform is built in a laboratory, and PD detection of an artificial defective cable is performed. The experimental results show that the signal relay system can effectively “enlarge” the PD pulse on a long-length cable. For long-length power cables, PD detection can achieve a higher localization accuracy based on the proposed method.

30 October 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Guangya ZhuGuangya Zhu
Guangya Zhu
ZLZhaogui Liu
Zhaogui Liu
SPSongkun Pan
Songkun Pan
PMPengfei Meng
Pengfei Meng
KZKai Zhou
Kai Zhou
HZHao Zhou
Hao Zhou
The penetration of moisture into power cable joints accelerates cable insulation degradation, ultimately leading to cable breakdowns and power outages. The determination of whether environmental moisture has penetrated an insulation interface and the discrimination of dampness status are, thus, significant tasks in cable operation, maintenance, and management. Therefore, a dampness discrimination method based on polarization and depolarization current (PDC) testing under thermal stimulation is presented here. Initially, a working principle of the PDC testing method for detecting moisture in cable joints is developed. Subsequently, a thorough description of the principle of dampness discrimination in cable joints is provided based on PDC testing under thermal stimulation. This analysis reveals that thermal stimulation may alter the phase state of water and the interface contact state between cross-linked polyethylene (XLPE) and silicone rubber (SiR), decreasing the conducting current of the cable. In addition, finite element simulations are employed to determine the parameters for the thermal stimulation methods. Finally, experimental results confirm the effectiveness of the proposed method in accurately identifying dampness defects in cable joints.

11 June 2025 in Journal of Applied Physics
Verified
Journal Article
Open access
Yuan LiYuan Li
Yuan Li
RLRanran Li
Ranran Li
KZKai Zhou
Kai Zhou
YXYefei Xu
Yefei Xu
CZChenjie Zhang
Chenjie Zhang
SJShangchen Ji
Shangchen Ji
Shock waves generated by streamer discharges in transformer oil are a critical factor leading to mechanical damage and explosion incidents in oil-immersed transformers. To clarify the mechanisms of shock wave generation and propagation, this study developed an experimental platform for streamer-induced shock waves and constructed a streamer model based on electrohydrodynamic drift-diffusion, along with a shock wave propagation model driven by volumetric pressure source density. According to the comparison between the simulation and experimental results, the accuracy of the streamer model and the shock wave propagation model was validated. The results show that the high electric field at the streamer tip induces localized ionization, forming plasma clusters. Moreover, plasma clusters generate concentrated volume pressure sources via electron energy absorption, with the source intensity sharply rising to 1.09 × 1020 s−2 upon streamer completion. Subsequently, under high-energy volume pressure sources, the shock wave exhibits typical spherical longitudinal wave characteristics: specifically, a pulse duration of 2.35 μs, a stable central frequency of 417 kHz, and amplitude decay following a power-law model. Finally, the study demonstrates that material interface acoustic impedances significantly alter shock wave behavior. Specifically, the oil–acrylic–air interface generates multi-peak oscillatory waveforms due to multipath interference, while the oil–acrylic interface amplifies wall pressure peaks by 42.1% through constructive interference. This study provides a theoretical foundation for understanding the mechanisms of shock wave generation and propagation induced by streamer discharge in oil.

18 June 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Yuan LiYuan Li
Yuan Li
RLRanran Li
Ranran Li
SYSenhong Yang
Senhong Yang
KZKai Zhou
Kai Zhou
YXYefei Xu
Yefei Xu
SJShangchen Ji
Shangchen Ji
During the long-term operation of transformers, conductive impurity particles within the transformer oil can significantly degrade its dielectric strength, potentially leading to transformer failures and causing substantial economic losses and adverse social impacts. To comprehensively understand the influence of conductive particles on the discharge characteristics of transformer oil, this paper systematically reviews the progress of relevant research. First, the theoretical framework of force models for conductive particles in transformer oil is introduced, and the effects of voltage type, amplitude, temperature, and flow rate on the motion state, velocity, bridging speed, and landing distance of conductive particles are summarized. Subsequently, the discharge types of transformer oil containing conductive particles are elaborated, and the mechanisms by which factors such as the number of conductive particles and voltage type affect the breakdown voltage are analyzed. The physical mechanisms through which conductive particles induce discharges in transformer oil are also outlined. Finally, methods for the detection and identification of particles in transformer oil are systematically reviewed, with a comparison of the applicability and advantages of different techniques, and future research directions are discussed. This review aims to provide theoretical references and practical guidance for the structural optimization and operational maintenance of transformers.

1 February 2020 in International Journal of Machine Tools and Manufacture
Verified
Journal Article
Closed access
WWWeixin Wang
Weixin Wang
CHChuxiong Hu
Chuxiong Hu
KZKai Zhou
Kai Zhou
SHSuqin He
Suqin He

1 October 2019
Verified
Conference Paper
Closed access
QZQi Zeng
Qi Zeng
KZKai Zhou
Kai Zhou
XZXing Zhang
Xing Zhang
PDPengfei Du
Pengfei Du
Inspired by the idea of mobile targets localization by the antenna array, a novel localization methodology for the partial discharge (PD) source in power systems is proposed by using ultra-high frequency (UHF) sensor-arrays in this paper. Due to the broadband feature of UHF-signals emitted from PD source, a focusing algorithm, i.e., two-sided correlation transformation (TCT) algorithm, is utilized to transform the PD signals to the narrowband ones, which improves the accuracy of the direction-of-arrival (DoA) estimation at the sensor-array under the severe electromagnetic surroundings. Then, with the DoAs obtained from multiple sensor-arrays, a spatial localization paradigm for the PD source is introduced. Finally, the PD source can be localized within a spatial sphere formed by the multiple skew DoA-lines from these sensor-arrays. Based on the simulation with the experimental PD UHF-signal data, it is shown that the proposed methodology accurately localizes the PD source within the a small range of sphere under the severe testing situations, which improves the accuracy of PD source localization compared with the classic time-difference-of-arrival (TDoA) method.