Senhong Yang

Senhong Yang

Auto-generated profile, based on publicly available information

Senhong Yang

College of Electrical Engineering, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Yuan LiYuan Li
Yuan Li
SYSenhong Yang
Senhong Yang
RLRanran Li
Ranran Li
HYHao Yuan
Hao Yuan
KZKai Zhou
Kai Zhou
Shakeel AkramShakeel Akram
Shakeel Akram
For oil-immersed power equipment, the accumulation of cellulose impurities in oil-paper insulation poses a significant problem. To address this issue, this study investigates the migration and bridging characteristics of cellulose impurities in oil-paper insulation under DC voltage. A kinetic analysis model is developed to simulate the impurity trajectories and quantitative analysis of speed, offset distance, and other parameters of cellulose impurities. The results indicate the motion cycle of cellulose impurity under the slightly uneven DC electric field consists of lifting, upward, and downward stages, with a maximum speed of over 10 2 mm/s and maximum acceleration of over 10 2 m/s 2 . During the lifting stage, particle velocity grows quickly and then slows, while during the downward stage velocity increases sharply to a maximum and then gradually decreases. The horizontal offset distance decreases with increased motion cycles. The cellulose impurities departed from the sphere electrode and the insulating paper surface migrate in opposite directions along their respective trajectories. As they gradually approach each other, these impurities undergo collisions and exchange charges, and eventually form a heap-like bridge. Results of this study can guide the development of better insulation materials for high-voltage electrical equipment and aid in the removal of impurities.

30 October 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Yuan LiYuan Li
Yuan Li
RLRanran Li
Ranran Li
SYSenhong Yang
Senhong Yang
CGCan Guo
Can Guo
YXYefei Xu
Yefei Xu
ZRZhaoyang Ran
Zhaoyang Ran
Cellulose impurities in transformer oil pose a significant threat to the reliability of converter transformers, with their concentration increasing during long-term operation, further compromising insulation performance. Therefore, it is crucial to investigate how the concentration of cellulose impurities affects the DC breakdown characteristics of transformer oil. For this purpose, the study constructed an experimental platform to explore the breakdown characteristics of transformer oil containing cellulose impurities under DC voltage. The results indicate that the breakdown voltage of transformer oil initially decreases, then increases, and eventually stabilizes with increasing cellulose impurity concentration. The maximum decrease and increase in breakdown voltage of transformer oil are 39.0% and 25.2%, respectively. Subsequently, observations were made using an optical diagnostic system, revealing that at low concentrations (≤0.005%), cellulose bridges exhibited periodic collapse, while at high concentrations (>0.005%), the bridges remained intact and bubbles appeared due to partial discharge (PD). Furthermore, physical and simulation models indicate that at low concentrations, breakdown is primarily associated with electric field distortion caused by cellulose impurities, while at high concentration, thermal effects from leakage current and PD dominate. Therefore, a Cellulose Retards Bubble Growth (CR-BG) model is proposed to describe how cellulose impurity concentrations inhibit bubble bridging and affect the breakdown voltage of transformer oil at high concentrations. These findings establish a quantitative relationship between cellulose concentration and the electrical strength of transformer oil under DC electric field, providing valuable engineering guidance for monitoring and maintenance work at the site.

18 June 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Yuan LiYuan Li
Yuan Li
RLRanran Li
Ranran Li
SYSenhong Yang
Senhong Yang
KZKai Zhou
Kai Zhou
YXYefei Xu
Yefei Xu
SJShangchen Ji
Shangchen Ji
During the long-term operation of transformers, conductive impurity particles within the transformer oil can significantly degrade its dielectric strength, potentially leading to transformer failures and causing substantial economic losses and adverse social impacts. To comprehensively understand the influence of conductive particles on the discharge characteristics of transformer oil, this paper systematically reviews the progress of relevant research. First, the theoretical framework of force models for conductive particles in transformer oil is introduced, and the effects of voltage type, amplitude, temperature, and flow rate on the motion state, velocity, bridging speed, and landing distance of conductive particles are summarized. Subsequently, the discharge types of transformer oil containing conductive particles are elaborated, and the mechanisms by which factors such as the number of conductive particles and voltage type affect the breakdown voltage are analyzed. The physical mechanisms through which conductive particles induce discharges in transformer oil are also outlined. Finally, methods for the detection and identification of particles in transformer oil are systematically reviewed, with a comparison of the applicability and advantages of different techniques, and future research directions are discussed. This review aims to provide theoretical references and practical guidance for the structural optimization and operational maintenance of transformers.