Jinzhao Han

Jinzhao Han

Auto-generated profile, based on publicly available information

Jinzhao Han

Institute of Technological Sciences, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Electrochimica Acta
Verified
Journal Article
Closed access
YPYunjie Ping
Yunjie Ping
SYShiju Yang
Shiju Yang
JHJinzhao Han
Jinzhao Han
XLXu Li
Xu Li
HZHaoliang Zhang
Haoliang Zhang
CHChunqing He
Chunqing He

4 April 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DRDiwang Ruan
Diwang Ruan
JHJinzhao Han
Jinzhao Han
JYJianping Yan
Jianping Yan
CGClemens Gühmann
Clemens Gühmann
Convolutional Neural Network (CNN) has been extensively used in bearing fault diagnosis and Remaining Useful Life (RUL) prediction. However, accompanied by CNN’s increasing performance is a deeper network structure and growing parameter size. This prevents it from being deployed in industrial applications with limited computation resources. To this end, this paper proposed a two-step method to build a cell-based light CNN by Neural Architecture Search (NAS) and weights-ranking-based model pruning. In the first step, a cell-based CNN was constructed with searched optimal cells and the number of stacking cells was limited to reduce the network size after influence analysis. To search for the optimal cells, a base CNN model with stacking cells was initially built, and Differentiable Architecture Search was adopted after continuous relaxation. In the second step, the connections in the built cell-based CNN were further reduced by weights-ranking-based pruning. Experiment data from the Case Western Reserve University was used for validation under the task of fault classification. Results showed that the CNN with only two cells achieved a test accuracy of 99.969% and kept at 99.968% even if 50% connections were removed. Furthermore, compared with base CNN, the parameter size of the 2-cells CNN was reduced from 9.677MB to 0.197MB. Finally, after minor revision, the network structure was adapted to achieve bearing RUL prediction and validated with the PRONOSTIA test data. Both tasks confirmed the feasibility and superiority of constructing a light cell-based CNN with NAS and pruning, which laid the potential to realize a light CNN in embedded systems.

13 March 2023 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Yuhao XiaoYuhao Xiao
Yuhao Xiao
JHJinzhao Han
Jinzhao Han
KZKewen Zhu
Kewen Zhu
GWGuoqiang Wu
Guoqiang Wu
A piezoelectrically actuated high quality factor (Q) mechanically coupled Lamé mode resonator based on a thin-film piezoelectric-on-silicon (TPoS) platform is demonstrated. The reported coupled resonator consists of two identical square plates of single-crystal silicon (SCS) coupled with a SCS beam having thin-film piezoelectric stacked layers on top. The coupled resonator is piezoelectrically driven into resonance, and the two square plates are excited into vibrations in a coupled Lamé mode through mechanical coupling. An impressive passive Q-enhancement is obtained by such a scheme based on mechanical coupling of two SCS square plates with a piezoelectrically transduced beam. A fabricated mechanically coupled Lamé mode resonator exhibits an ultra-high Q of 309 894 while still maintaining a moderate impedance (Rm) of 6652 Ω at its resonant frequency of 18.2838 MHz, corresponding to the record highest f-Q product of 5.67 × 1012 for TPoS resonators. The reported high Q microelectromechanical system (MEMS) resonator overcomes the inherent low-Q nature of piezoelectric MEMS resonators, indicating an application for providing a high-performance timing solution in a MEMS timing field.

13 June 2023 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
Yuhao XiaoYuhao Xiao
Yuhao Xiao
JHJinzhao Han
Jinzhao Han
KZKewen Zhu
Kewen Zhu
GWGuoqiang Wu
Guoqiang Wu
This letter presents a dual-mode piezoelectric microelectromechanical system (MEMS) resonator with an in-chip micro-oven for resonator temperature control. The piezoelectric MEMS resonator simultaneously operates in width-extensional (WE) mode with a high temperature turnover point, and torsion-bending (TB) mode with a large temperature coefficient of frequency (TCF) based on a phase-locked loop based system. Exploiting the difference in frequency-temperature characteristics of these two modes, accurate temperature sensing and precise close-loop micro-oven heating control are achieved by phase locking the resonator at its turnover point temperature of WE mode. Measured real-time frequency stability of the reported micro-oven controlled MEMS resonator is ±190 ppb over an extended industrial temperature range of -40 °C to 105 °C, indicating potential applications in high-end timing field, such as macro base stations and instrumentations.

30 March 2023 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
JHJinzhao Han
Jinzhao Han
Yuhao XiaoYuhao Xiao
Yuhao Xiao
WCWen Chen
Wen Chen
KZKewen Zhu
Kewen Zhu
GWGuoqiang Wu
Guoqiang Wu
This paper presents mechanically coupled single-crystal silicon (SCS) microelectromechanical system (MEMS) resonators for temperature coefficient of frequency (TCF) manipulation. The reported mechanically coupled square extensional (SE) mode resonator consists of two square plates coupled with a beam or a third square plate purposely vibrating in another bulk mode. The SE mode resonators and the coupled structure can be considered as two kinds of individual resonators with different TCFs. Within the specific dimensions of the coupled resonator, the resonant frequencies of the two components are assumed to be equal. Hence, the TCF of the mechanically coupled resonator could be manipulated by adjusting the sizes of the coupling parts. The design and fabrication of coupled resonators have been completed in a degenerate-doped (100) SCS wafer. Measurement results illustrate that the TCFs of the coupled resonators can be purposely manipulated by adjusting the volume and equivalent spring constant ratios of the individual resonators. The minimal measured frequency shift is roughly $\pm$ 10 ppm for an 18 MHz coupled SE mode resonator, over the entire industrial temperature range of $-$ 40 $^{\circ}$ C to 85 $^{\circ}$ C. This work highlights a novel and effective way to manipulate the TCFs of MEMS resonators via mechanical coupling. 2022-0197

13 January 2025 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
Yuhao XiaoYuhao Xiao
Yuhao Xiao
JHJinzhao Han
Jinzhao Han
BLBowen Li
Bowen Li
GWGuoqiang Wu
Guoqiang Wu
This paper presents an effective approach for adjusting the zero temperature coefficient of frequency (turnover point) in mechanically coupled single-crystal silicon (SCS) microelectromechanical system (MEMS) resonators. The mechanically coupled MEMS resonators are fabricated on a heavily n-type doped SCS with a phosphorus doping concentration of around $1.0\times 10^{20}$ cm $-3$ for achieving high turnover points. A turnover point tuning prediction model is derived, showing that the turnover point of mechanically coupled resonators can be represented as the weighted average sum of the product of the effective mass and the second order $TCF$ of each individual resonator, along with its corresponding turnover point. By leveraging mechanical coupling between breathing-ring (BR) mode resonators and length-extensional (LE) or width-extensional (WE) mode resonators, the turnover point of mechanically coupled resonator can be purposely manipulated to above industrial temperature ranges by adjusting the dimensions of the coupled components. Such turnover temperatures can be employed in micro-oven-controlled MEMS oscillators (OCMOs) to achieve excellent frequency stability. The results offer valuable insights into optimizing the frequency-temperature characteristic of MEMS resonators in high-end timing field. 2024-0184