Yuhao Xiao

Dr. Yuhao Xiao

School of Integrated Circuits, Wuhan University, Wuhan, Hubei, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2021 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
WCWen Chen
Wen Chen
WJWenhan Jia
Wenhan Jia
Yuhao XiaoYuhao Xiao
Yuhao Xiao
ZFZhihong Feng
Zhihong Feng
GWGuoqiang Wu
Guoqiang Wu
In this letter, we report a highly temperature-stable and low impedance scandium doped aluminum nitride (Sc x AI 1-x N, x=9.5%) on silicon piezoelectric microelectromechanical system (MEMS) resonator. Passive temperature compensation techniques, including heavy doping and composite structure using oxide layers, are employed to minimize the frequency drifts over temperature of the piezoelectric MEMS resonator. The turnover point is adjusted by changing the in-plane crystal orientation of the (100) doped device silicon wafer. A frequency variation of ±21.5 ppm over the industry temperature range from -40 °C to 85 °C is achieved when the crystal orientation of the device silicon wafer is arranged at around 22.5° from the <;110> direction. The measured loaded quality factor ( Q l ) is 10017 with a motional impedance of 28 Ω at its series resonant frequency of 24.44 MHz. The deduced unloaded quality factor ( Q un ) is above 45000. Thanks to the excellent temperature stability and low impedance, the reported piezoelectric MEMS resonator shows great potential to directly replace the classical quartz crystal resonators without any active temperature compensation.

20 July 2022 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
JHJinzhao Han
Jinzhao Han
Yuhao XiaoYuhao Xiao
Yuhao Xiao
WCWen Chen
Wen Chen
WJWenhan Jia
Wenhan Jia
KZKewen Zhu
Kewen Zhu
GWGuoqiang Wu
Guoqiang Wu
This letter reports temperature compensated single crystal silicon (SCS) bulk-mode capacitive microelectromechanical system (MEMS) resonators with high temperature stability of less than ±20 ppm over industrial temperature range. Degenerate doping is adopted to change the temperature coefficient of frequency ( $TCF$ ) and adjusting of crystal orientation is implemented to tune the turnover points for the MEMS resonators, thanks to the different temperature coefficient of elastic constants ( $TCE$ ) of the resonators along different crystal orientation. The adjustment effects are verified by using finite element method (FEM) simulations as well as measurement results. Two bulk-modes, namely length-extensional (LE) and square-extensional (SE) mode resonators along various crystal orientations in a degenerate-doped (100) SCS wafer are designed and fabricated. The measurement frequency shifts are approximately ±20 ppm for the LE mode resonator and ±16 ppm for the SE mode resonator as the resonators are placed along 22.5° from the direction over industrial temperature range of −40°C to 85 °C, respectively. It highlights an effective way to reduce the $TCF$ via degenerate doping and precisely adjust the turnover point by crystal orientation tuning for MEMS resonators. [2022-0046]

25 March 2022 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
WCWen Chen
Wen Chen
WJWenhan Jia
Wenhan Jia
Yuhao XiaoYuhao Xiao
Yuhao Xiao
GWGuoqiang Wu
Guoqiang Wu
In this paper, the design, modeling and characterization of width-extensional (WE) mode piezoelectric microelectromechanical systems (MEMS) resonators are presented. The resonators consist of piezoelectric stacked layers for transductions, highly doped single crystal silicon (HDS) device layer as vibrating structures, and oxide layers on top and bottom surfaces for passive temperature compensation. Dependencies of quality factors ( $Q\text{s}$ ) of the WE mode resonators on structure designs, such as device length, thickness as well as crystal orientation of the HDS device layer are investigated. Effects of crystal orientation of the HDS device layer and oxide thickness on the temperature stability of resonant frequency of the WE mode resonators are also analyzed. Both aluminum nitride (AlN) and scandium-doped aluminum nitride (Sc x Al 1−x N, $x=9.5\%$ ) are adopted as the piezoelectric transduction layer in this work, in order to investigate the performance improvements by Sc doping. The designed WE mode MEMS resonators are fabricated based on a piezoelectric on cavity-silicon-on-insulator (CSOI) platform. A fabricated ScAlN-based MEMS resonator exhibits a $Q$ of 11086 and motional impedance as low as 28 $\Omega $ at its series resonant frequency of 25.044 MHz. [2021-0222]

25 March 2022 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
WJWenhan Jia
Wenhan Jia
WCWen Chen
Wen Chen
Yuhao XiaoYuhao Xiao
Yuhao Xiao
ZWZhongye Wu
Zhongye Wu
GWGuoqiang Wu
Guoqiang Wu
In this article, the design, implementation, and characterization of a micro-oven-controlled dual-mode piezoelectric microelectromechanical system (MEMS) resonator are presented. The designed MEMS resonator simultaneously operates in the width extensional (WE) mode and length shear (LS) mode. Both modes show high quality factor ( ${Q}$ ). The measured ${Q}$ is 15672 for the WE mode and 17781 for the LS mode. Taking advantage of the significant difference in frequency–temperature characteristics between the two modes, accurate temperature sensing and precisely closed-loop micro-oven control are implemented by phase locking the MEMS resonator at an oven-set temperature. In-plane micro-oven is composed of four folded beams and an isolation frame, which maintains an extremely uniform temperature distribution on the resonating element. The micro-oven structure requires less than 7.8 mW to maintain the resonator’s temperature at the preset temperature over variations in the external temperature range of −40 °C to 80 °C. Measured real-time frequency stability of the reported micro-oven-controlled MEMS resonator is less than ±400 ppb over a wide temperature range from −40 °C to 80 °C.

13 March 2023 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Yuhao XiaoYuhao Xiao
Yuhao Xiao
JHJinzhao Han
Jinzhao Han
KZKewen Zhu
Kewen Zhu
GWGuoqiang Wu
Guoqiang Wu
A piezoelectrically actuated high quality factor (Q) mechanically coupled Lamé mode resonator based on a thin-film piezoelectric-on-silicon (TPoS) platform is demonstrated. The reported coupled resonator consists of two identical square plates of single-crystal silicon (SCS) coupled with a SCS beam having thin-film piezoelectric stacked layers on top. The coupled resonator is piezoelectrically driven into resonance, and the two square plates are excited into vibrations in a coupled Lamé mode through mechanical coupling. An impressive passive Q-enhancement is obtained by such a scheme based on mechanical coupling of two SCS square plates with a piezoelectrically transduced beam. A fabricated mechanically coupled Lamé mode resonator exhibits an ultra-high Q of 309 894 while still maintaining a moderate impedance (Rm) of 6652 Ω at its resonant frequency of 18.2838 MHz, corresponding to the record highest f-Q product of 5.67 × 1012 for TPoS resonators. The reported high Q microelectromechanical system (MEMS) resonator overcomes the inherent low-Q nature of piezoelectric MEMS resonators, indicating an application for providing a high-performance timing solution in a MEMS timing field.

8 June 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WCWen Chen
Wen Chen
WJWenhan Jia
Wenhan Jia
Yuhao XiaoYuhao Xiao
Yuhao Xiao
GWGuoqiang Wu
Guoqiang Wu
In this paper, a new approach by introducing auxiliary structures in the tethers of microelectromechanical system (MEMS) resonator is presented to reduce anchor loss. Capacitive square-extensional (SE) mode resonator with folded beam tether is adopted to verify the feasibility of the proposed approach in both finite element method (FEM) analysis and measurement. In FEM simulations, perfectly matched layer (PML) boundary condition is applied in order to estimate anchor loss of the designed MEMS resonators. With the aid of the auxiliary structures, quality factors (Qs) of the designed SE mode MEMS resonators are significantly improved. The measured Q of the fabricated SE mode resonator is improved by approximately 62% after introducing auxiliary structures in the tethers of the resonator without any further treatments on resonator structure or tether design. The proposed approach provides a simple and effective way to suppress anchor loss and hence improve Q for the presented MEMS resonators.