Albert Einstein Center for Fundamental Physics (AEC), Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland
Auto-generated profile, based on publicly available information
Alexander Gottstein
Albert Einstein Center for Fundamental Physics (AEC), Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland
We report on a search for dark matter axionlike particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows one to constrain the coupling of ALPs to gluons in the mass range from to . The best limit of (95% C.L.) is reached in the mass range from to .
19 December 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
The theranostic pair 133La/135La has recently attracted growing interest as a promising candidate for combined diagnostic and therapeutic applications, owing to the favorable nuclear and chemical properties of lanthanum. 135La (t1/2 = 18.91 h) decays by electron capture (EC) to the ground state of 135Ba, emitting Auger cascade electrons that are potentially useful for targeted internal radiotherapy. In contrast, 133La (t1/2 = 3.912 h) is a β+-emitter suitable for PET imaging. Moreover, 133La has been proposed as a diagnostic partner for 225Ac (t1/2 = 9.9 d), due to their close chemical similarity and the longer half-life of 133La compared with other PET radiometals such as 68Ga (t1/2 = 1.13 h). A feasible approach for producing 133La and 135La is the irradiation of enriched 134Ba and 135Ba targets, respectively, with low- to medium-energy proton beams (up to 25 MeV maximum energy) readily available from medical cyclotrons. Although these production routes have been previously explored, the available nuclear data on lanthanum radioisotopes remain limited and often inconsistent. In this work, we measured the cross sections of reactions producing lanthanum isotopes up to 18 MeV, using natural BaCO3 as well as enriched 134BaCO3 and 135BaCO3 targets, with some cross sections reported here for the first time. The half-lives of La radioisotopes were also determined and compared with the literature values. The resulting data were used to optimize the production parameters for 133La and 135La, and several irradiation tests were carried out to validate our findings.
The theranostic pair 133La/135La has recently attracted growing interest as a promising candidate for combined diagnostic and therapeutic applications, owing to the favorable nuclear and chemical properties of lanthanum. 135La (t1/2 = 18.91 h) decays by electron capture (EC) to the ground state of 135Ba, emitting Auger cascade electrons that are potentially useful for targeted internal radiotherapy. In contrast, 133La (t1/2 = 3.912 h) is a β+-emitter suitable for PET imaging. Moreover, 133La has been proposed as a diagnostic partner for 225Ac (t1/2 = 9.9 d), due to their close chemical similarity and the longer half-life of 133La compared with other PET radiometals such as 68Ga (t1/2 = 1.13 h).A feasible approach for producing 133La and 135La is the irradiation of enriched 134Ba and 135Ba targets, respectively, with low- to medium-energy proton beams (up to 25 MeV maximal energy) readily available from medical cyclotrons. Although these production routes have been previously explored, the available nuclear data on lanthanum radioisotopes remain limited and often inconsistent. In this work, we measured the cross sections of reactions producing lanthanum isotopes up to 18 MeV, using natural BaCO3 as well as enriched 134BaCO3 and 135BaCO3 targets, with some cross sections reported here for the first time. The half-lives of La radioisotopes were also determined and compared with the literature values. The resulting data were used to optimize the production parameters for 1La and 135La, and several irradiation tests were carried out to validate our findings.
Non-destructive beam diagnostics are essential for low-energy medical cyclotrons, where even thin interceptive devices can severely degrade beam quality. We investigate an external fiber monitor (EFM) based on Ce-doped silica scintillating fibers that detects secondary radiation generated at existing beamline components of the 18 MeV Bern Medical Cyclotron beam transfer line (BTL). Three use cases were studied: (i) beam intensity monitoring around an electrically isolated, water-cooled beam dump; (ii) beam-loss monitoring around a 10 mm collimator under varying the beam focusing; and (iii) by steering a 6.5 mm $\times$ 6.5 mm beam spot on a beam dump. For case (i), the summed EFM signal exhibits a linear dependence on the current on target over nearly three orders of magnitude. In case (ii), a normalized EFM-based beam-loss proxy scales monotonically with an electrical loss proxy across several focusing settings. Furthermore, opposing-fiber signal ratios provide decoupled, monotonic sensitivity to horizontal and vertical beam displacements.
Non-destructive beam diagnostics are essential for low-energy medical cyclotrons, where even thin interceptive devices can severely degrade beam quality. We investigate an external fiber monitor (EFM) based on Ce-doped silica scintillating fibers that detects secondary radiation generated at existing beamline components of the 18 MeV Bern Medical Cyclotron beam transfer line (BTL). Three use cases were studied: (i) beam intensity monitoring around an electrically isolated, water-cooled beam dump; (ii) beam-loss monitoring around a 10 mm collimator under varying the beam focusing; and (iii) by steering a 6×6 mm beam spot on a beam dump. For case (i), the summed EFM signal exhibits a linear dependence on the current on target over nearly three orders of magnitude. In case (ii), a normalized EFM-based beam-loss proxy scales monotonically with an electrical loss proxy across several focusing settings. Furthermore, opposing-fiber signal ratios provide decoupled, monotonic sensitivity to horizontal and vertical beam displacements.