We report on a search for dark matter axionlike particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows one to constrain the coupling of ALPs to gluons in the mass range from to . The best limit of (95% C.L.) is reached in the mass range from to .
Silicon carbide (SiC) is a wide band gap semiconductor and an attractive candidate for applications in harsh environments such as space, fusion, or future high luminosity colliders. Due to the large band gap, the leakage currents in SiC devices are extremely small, even after irradiation to very high fluences, enabling operation without cooling and at high temperatures. This study investigates the effect of neutron irradiation on 50 μm p-n 4H-SiC diodes using current-voltage, capacitance-voltage, and charge collection efficiency (CCE) measurements up to neutron fluences of 1 × 1016neq/cm2. The leakage currents of the investigated devices remained extremely small, below 10 pA at 1.1 kV reverse bias. In the forward bias, a remarkable drop of the current was observed, which was attributed to an increased epi resistivity due to compensation of the epi layer doping by deep-level defects. The CCE was evaluated for alpha particles from a radioactive source, a 62.4 MeV proton beam at the MedAustron ion therapy center and using UV-TCT. The charge collection efficiency in reverse bias was shown to scale directly with the 1 MeV equivalent fluence Φeq as CCE∝Φeq-0.63±0.01. A CCE better than 50% was able to be obtained for fluences up to 1 × 1015neq/cm2. Because of the low currents in the forward direction, particle detection was also possible in forward bias, where the CCE was found to be increased relative to reverse bias. Furthermore, a significant dependency on the amount of injected charge was observed, with the CCE surpassing 100% in alpha and UV-TCT measurements, requiring further systematic investigation.
30 October 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is completely built from off-the-shelf components and is focused on compactness and simple deployment. Beam tests using a 50 um thick SiC detector reveal, that for low fluences, single particles can be detected and counted. For higher fluences, beam properties were extracted from beam cross sections using a silicon strip detector. Overall, accurate results were achieved up to a particle rate of 109 particles per second.
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide bandgap makes it an interesting candidate for radiation-hard particle detectors in high-energy physics and medical applications. Furthermore, the high electron and hole drift velocities in 4H-SiC enable devices suitable for ultra-fast particle detection and timing applications. However, currently, the front-end readout electronics used for 4H-SiC detectors constitute a bottleneck in investigations of the charge carrier drift. To address these limitations, a high-frequency readout board with an intrinsic bandwidth of 10 GHz was developed. With this readout, the transient current signals of a 4H-SiC diode with a diameter of 141 μm and a thickness of 50 μm upon UV laser, alpha particle, and high-energy proton beam excitation were recorded. In all three cases, the electron and hole drift can clearly be separated, which enables the extraction of the charge carrier drift velocities as a function of the electric field. These velocities, directly measured for the first time, provide a valuable comparison to Monte Carlo-simulated literature values and constitute an essential input for TCAD simulations. Finally, a complete simulation environment combining TCAD, the Allpix2 framework, and SPICE simulations is presented, which is in good agreement with the measured data.