1 March 1998 in IEEE Transactions on Rehabilitation Engineering
The authors' goal is to apply robotics and automation technology to assist, enhance, quantify, and document neurorehabilitation. This paper reviews a clinical trial involving 20 stroke patients with a prototype robot-aided rehabilitation facility developed at the Massachusetts Institute of Technology, Cambridge, (MIT) and tested at Burke Rehabilitation Hospital, White Plains, NY. It also presents the authors' approach to analyze kinematic data collected in the robot-aided assessment procedure. In particular, they present evidence (1) that robot-aided therapy does not have adverse effects, (2) that patients tolerate the procedure, and (3) that peripheral manipulation of the impaired limb may influence brain recovery. These results are based on standard clinical assessment procedures. The authors also present one approach using kinematic data in a robot-aided assessment procedure.
17 September 2007 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In 1991, a novel robot, MIT-MANUS, was introduced to study the potential that robots might assist in and quantify the neuro-rehabilitation of motor function. MIT-MANUS proved an excellent tool for shoulder and elbow rehabilitation in stroke patients, showing in clinical trials a reduction of impairment in movements confined to the exercised joints. This successful proof of principle as to additional targeted and intensive movement treatment prompted a test of robot training examining other limb segments. This paper focuses on a robot for wrist rehabilitation designed to provide three rotational degrees-of-freedom. The first clinical trial of the device will enroll 200 stroke survivors. Ultimately 160 stroke survivors will train with both the proximal shoulder and elbow MIT-MANUS robot, as well as with the novel distal wrist robot, in addition to 40 stroke survivor controls. So far 52 stroke patients have completed the robot training (ongoing protocol). Here, we report on the initial results on 36 of these volunteers. These results demonstrate that further improvement should be expected by adding additional training to other limb segments.
26 October 2004 in Journal of NeuroEngineering and Rehabilitation
Background: Previous results with the planar robot MIT-MANUS demonstrated positive benefits in trials with over 250 stroke patients. Consistent with motor learning, the positive effects did not generalize to other muscle groups or limb segments. Therefore we are designing a new class of robots to exercise other muscle groups or limb segments. This paper presents basic engineering aspects of a novel robotic module that extends our approach to anti-gravity movements out of the horizontal plane and a pilot study with 10 outpatients. Patients were trained during the initial six-weeks with the planar module (i.e., performance-based training limited to horizontal movements with gravity compensation). This training was followed by six-weeks of robotic therapy that focused on performing vertical arm movements against gravity. The 12-week protocol includes three one-hour robot therapy sessions per week (total 36 robot treatment sessions). Results: Pilot study demonstrated that the protocol was safe and well tolerated with no patient presenting any adverse effect. Consistent with our past experience with persons with chronic strokes, there was a statistically significant reduction in tone measurement from admission to discharge of performance-based planar robot therapy and we have not observed increases in muscle tone or spasticity during the anti-gravity training protocol. Pilot results showed also a reduction in shoulder-elbow impairment following planar horizontal training. Furthermore, it suggested an additional reduction in shoulder-elbow impairment following the anti-gravity training. Conclusion: Our clinical experiments have focused on a fundamental question of whether task specific robotic training influences brain recovery. To date several studies demonstrate that in mature and damaged nervous systems, nurture indeed has an effect on nature. The improved recovery is most pronounced in the trained limb segments. We have now embarked on experiments that test whether we can continue to influence recovery, long after the acute insult, with a novel class of spatial robotic devices. This pilot results support the pursuit of further clinical trials to test efficacy and the pursuit of optimal therapy following brain injury.
14 August 2009 in Neurorehabilitation and Neural Repair
Background. Human-administered clinical scales are the accepted standard for quantifying motor performance of stroke subjects. Although they are widely accepted, these measurement tools are limited by interrater and intrarater reliability and are time-consuming to apply. In contrast, robot-based measures are highly repeatable, have high resolution, and could potentially reduce assessment time. Although robotic and other objective metrics have proliferated in the literature, they are not as well established as clinical scales and their relationship to clinical scales is mostly unknown. Objective. To test the performance of linear regression models to estimate clinical scores for the upper extremity from systematic robot-based metrics. Methods. Twenty kinematic and kinetic metrics were derived from movement data recorded with the shoulder-and-elbow InMotion2 robot (Interactive Motion Technologies, Inc), a commercial version of the MIT-Manus. Kinematic metrics were aggregated into macro-metrics and micro-metrics and collected from 111 chronic stroke subjects. Multiple linear regression models were developed to calculate Fugl-Meyer Assessment, Motor Status Score, Motor Power, and Modified Ashworth Scale from these robot-based metrics. Results. Best performance—complexity trade-off was achieved by the Motor Status Score model with 8 kinematic macro-metrics (R = .71 for training; R = .72 for validation). Models including kinematic micro-metrics did not achieve significantly higher performance. Performances of the Modified Ashworth Scale models were consistently low (R = .35-.42 for training; R = .08-.17 for validation). Conclusions. The authors identified a set of kinetic and kinematic macro-metrics that may be used for fast outcome evaluations. These metrics represent a first step toward the development of unified, automated measures of therapy outcome.
13 April 1999 in Proceedings of the National Academy of Sciences
Segmentation of apparently continuous movement has been reported for over a century by human movement researchers, but the existence of primitive submovements has never been proved. In 20 patients recovering from a single cerebral vascular accident (stroke), we identified the apparent submovements that composed a continuous arm motion in an unloaded task. Kinematic analysis demonstrated a submovement speed profile that was invariant across patients with different brain lesions and provided experimental verification of the detailed shape of primitive submovements. The submovement shape was unaffected by its peak speed, and to test further the invariance of shape with speed, we analyzed movement behavior in a patient with myoclonus. This patient occasionally made involuntary shock-like arm movements, which occurred near the maximum capacity of the neuromuscular system, exhibited speed profiles that were comparable to those identified in stroke patients, and were also independent of speed.
1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Several studies investigating the use of electromyographic (EMG) signals in robot-based stroke neuro-rehabilitation to enhance functional recovery. Here we explored whether a classical EMG-based patterns recognition approach could be employed to predict patients’ intentions while attempting to generate goal-directed movements in the horizontal plane. Nine right-handed healthy subjects and seven right-handed stroke survivors performed reaching movements in the horizontal plane. EMG signals were recorded and used to identify the intended motion direction of the subjects. To this aim, a standard pattern recognition algorithm (i.e., Support Vector Machine, SVM) was used. Different tests were carried out to understand the role of the inter- and intra-subjects’ variability in affecting classifier accuracy. Abnormal muscular spatial patterns generating misclassification were evaluated by means of an assessment index calculated from the results achieved with the PCA, i.e., the so-called Coefficient of Expressiveness (CoE). Processing the EMG signals of the healthy subjects, in most of the cases we were able to build a static functional map of the EMG activation patterns for point-to-point reaching movements on the horizontal plane. On the contrary, when processing the EMG signals of the pathological subjects a good classification was not possible. In particular, patients’ aimed movement direction was not predictable with sufficient accuracy either when using the general map extracted from data of normal subjects and when tuning the classifier on the EMG signals recorded from each patient. The experimental findings herein reported show that the use of EMG patterns recognition approach might not be practical to decode movement intention in subjects with neurological injury such as stroke. Rather than estimate motion from EMGs, future scenarios should encourage the utilization of these signals to detect and interpret the normal and abnormal muscle patterns and provide feedback on their correct recruitment.