17 September 2007 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In 1991, a novel robot, MIT-MANUS, was introduced to study the potential that robots might assist in and quantify the neuro-rehabilitation of motor function. MIT-MANUS proved an excellent tool for shoulder and elbow rehabilitation in stroke patients, showing in clinical trials a reduction of impairment in movements confined to the exercised joints. This successful proof of principle as to additional targeted and intensive movement treatment prompted a test of robot training examining other limb segments. This paper focuses on a robot for wrist rehabilitation designed to provide three rotational degrees-of-freedom. The first clinical trial of the device will enroll 200 stroke survivors. Ultimately 160 stroke survivors will train with both the proximal shoulder and elbow MIT-MANUS robot, as well as with the novel distal wrist robot, in addition to 40 stroke survivor controls. So far 52 stroke patients have completed the robot training (ongoing protocol). Here, we report on the initial results on 36 of these volunteers. These results demonstrate that further improvement should be expected by adding additional training to other limb segments.
15 August 2012 in Journal of Neurophysiology
Because wrist rotation dynamics are dominated by stiffness (Charles SK, Hogan N. J Biomech 44: 614–621, 2011), understanding how humans plan and execute coordinated wrist rotations requires knowledge of the stiffness characteristics of the wrist joint. In the past, the passive stiffness of the wrist joint has been measured in 1 degree of freedom (DOF). Although these 1-DOF measurements inform us of the dynamics the neuromuscular system must overcome to rotate the wrist in pure flexion-extension (FE) or pure radial-ulnar deviation (RUD), the wrist rarely rotates in pure FE or RUD. Instead, understanding natural wrist rotations requires knowledge of wrist stiffness in combinations of FE and RUD. The purpose of this report is to present measurements of passive wrist stiffness throughout the space spanned by FE and RUD. Using a rehabilitation robot designed for the wrist and forearm, we measured the passive stiffness of the wrist joint in 10 subjects in FE, RUD, and combinations. For comparison, we measured the passive stiffness of the forearm (in pronation-supination), as well. Our measurements in pure FE and RUD agreed well with previous 1-DOF measurements. We have linearized the 2-DOF stiffness measurements and present them in the form of stiffness ellipses and as stiffness matrices useful for modeling wrist rotation dynamics. We found that passive wrist stiffness was anisotropic, with greater stiffness in RUD than in FE. We also found that passive wrist stiffness did not align with the anatomical axes of the wrist; the major and minor axes of the stiffness ellipse were rotated with respect to the FE and RUD axes by ∼20°. The direction of least stiffness was between ulnar flexion and radial extension, a direction used in many natural movements (known as the “dart-thrower's motion”), suggesting that the nervous system may take advantage of the direction of least stiffness for common wrist rotations.
1 February 2011 in Journal of Biomechanics
25 March 2014 in IEEE Transactions on Biomedical Engineering
Because the dynamics of wrist rotations are dominated by stiffness, understanding wrist rotations requires a thorough characterization of wrist stiffness in multiple degrees of freedom. The only prior measurement of multivariable wrist stiffness was confined to approximately one-seventh of the wrist range of motion (ROM). Here, we present a precise nonlinear characterization of passive wrist joint stiffness over a range three times greater, which covers approximately 70% of the functional ROM of the wrist. We measured the torque–displacement vector field in 24 directions and fit the data using thin-plate spline smoothing optimized with generalized cross validation. To assess anisotropy and nonlinearity, we subsequently derived several different approximations of the stiffness due to this multivariable vector field. The directional variation of stiffness was more pronounced than reported previously. A linear approximation (obtained by multiple linear regression over the entire field) was significantly more anisotropic (eigenvalue ratio of 2.69 ± 0.52 versus 1.58 ± 0.39; $p < 0.001$ ) though less misaligned with the anatomical wrist axes (12.1 ± 4.6° versus 21.2 ± 9.2°; $p < 0.001$ ). We also found that stiffness over this range exhibited considerable nonlinearity—the error associated with a linear approximation was 20–30%. The nonlinear characterization over this greater range confirmed significantly greater stiffness in radial deviation compared to ulnar deviation. This study provides a characterization of passive wrist stiffness better suited to investigations of natural wrist rotations, which cover much of the wrist's ROM. It also provides a baseline for the study of neurological and/or orthopedic disorders that result in abnormal wrist stiffness.
1 January 2013 in Frontiers in Computational Neuroscience
Given the vast complexity of human actions and interactions with objects, we proposed that control of sensorimotor behavior may utilize dynamic primitives. However, greater computational simplicity may come at the cost of reduced versatility. Evidence for primitives may be garnered by revealing such limitations. This study tested subjects performing a sequence of progressively faster discrete movements, in order to “stress” the system. We hypothesized that the increasing pace would elicit a transition to rhythmic movements, assumed to be computationally and neurally more efficient. Abrupt transitions between the two types of movements would support the hypothesis that rhythmic and discrete movements are distinct primitives. Ten subjects performed planar point-to-point arm movements paced by a metronome: Starting at 2s the metronome intervals decreased by 36ms per cycle to 200ms, stayed at 200ms for several cycles, then increased by similar increments. Instructions emphasized to insert explicit stops between each movement with a duration that equaled the movement time. The experiment was performed with eyes open and closed, and with short and long metronome sounds, the latter explicitly specifying the dwell duration. Results showed that subjects matched instructed movement times but did not preserve the dwell times. Rather, they progressively reduced dwell time to zero, transitioning to continuous rhythmic movements before movement times reached their minimum. The acceleration profiles showed an abrupt change between discrete and rhythmic profiles. The loss of dwell time occurred earlier with long auditory specification, when subjects also showed evidence of predictive control. While evidence for hysteresis was weak, taken together, the results clearly indicated a transition between discrete and rhythmic movements, supporting the proposal that representation is based on primitives rather than on veridical internal models.
11 April 2010 in Experimental Brain Research