This paper discusses the issue of modeling a hybrid renewable energy system for a selected microgrid which is connected to the public distribution system. The subject of the study is a hybrid of solar panels, wind turbine and generalized energy storage. Presented model uses statistical indices of solar irradiation and wind speed data to simulate power flow in the system. The voltage variations character has been analyzed considering possible modes of wind generator reactive power control. Optimal reactive power control requirements are shown in consideration of voltage variation mitigation. The objective of the work is to create a tool for feasibility assessment of the energy hybrid system component operation and appropriate control strategy to provide its efficiency.
In the paper Z-transform based on pole/zero matching method is proposed for high-speed computer simulation of electromagnetic transients in power systems with the purpose of their stability analysis. The application of Z-transform method is illustrated on example of simple electrical circuit.
1 January 2024 in Modelling and Simulation in Engineering
We propose a variant of the application of a phenomenological approach using the “black box” concept to the modeling of electrotechnical systems. The method enables obtaining simplified models of a complex electrotechnical system based on a synchronous generator (SG) with an excitation system and an integral estimation of the accuracy of the reproduction of the original step response. The compromise between complexity and accuracy is the basis for obtaining the computer model of different orders utilizing the proposed method. The application of the proposed phenomenological approach is illustrated by the examples.
This paper discusses the issue of modeling voltage flicker compensation devices in electric arc furnace power supply system. Simple algorithms of modeling the arc furnace and the compensating device are presented. In the proposed model, the statistical indices of arc furnace active and reactive powers and their harmonic approximation in each time interval of one second are used. Such approach allows us to use the index $\Delta U_{10}$ to estimate the equivalent effect of voltage fluctuations. The most annoying voltage fluctuations are within the frequency range of 1-25 Hz, and the efficiency of compensation devices in EAF power supply systems is dependent by their ability to reduce these fluctuations. The objective of the work is to create a simple tool for comparative assessment of compensation devices impact on voltage flicker in the EAF power supply system.