Paris Vakiel

Paris Vakiel

Auto-generated profile, based on publicly available information

Paris Vakiel

Department of Mechanical Engineering, University of Victoria, Victoria, Canada

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2022 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
YLYizhao Li
Yizhao Li
KAKevin Adanty
Kevin Adanty
PVParis Vakiel
Paris Vakiel
SOSimon Ouellet
Simon Ouellet
AVAlbert H. Vette
Albert H. Vette
CDChristopher R. Dennison
Christopher R. Dennison
Head injuries account for 15%–20% of all military injuries and pose a high risk of causing functional disability and fatality. Blunt ballistic impacts are one of the threats that can lead to severe head injuries. This review aims to examine the mechanisms and injury risk assessment associated with blunt ballistic head injury (BBHI). The review further discusses research methods and instrumentation used in BBHI studies, focusing on their limitations and challenges. Studies on the mechanisms of focal and diffuse brain injuries remain largely inconclusive and require further effort. Some studies have attempted to associate BBHIs with head mechanics, but more research is required to establish correlations between head mechanics and injury severity. Limited access to experimental models and a lack of instrumentation capable of measuring the mechanics of brain tissue in situ are potential reasons for the lack of understanding of injury mechanisms, injury correlations, and injury tolerance levels specific to this loading regime. Targeted research for understanding and assessing head injuries in blunt ballistic impacts is a necessary step in improving our ability to design protection systems to mitigate these injuries.

22 October 2020 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
PVParis Vakiel
Paris Vakiel
MSMehdi Shekarforoush
Mehdi Shekarforoush
CDChristopher R. Dennison
Christopher R. Dennison
MSMichael Scott
Michael Scott
GMGregory Muench
Gregory Muench
NSNigel G. Shrive
Nigel G. Shrive

22 October 2020 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
PVParis Vakiel
Paris Vakiel
CDChristopher R. Dennison
Christopher R. Dennison
MSMehdi Shekarforoush
Mehdi Shekarforoush
MSMichael Scott
Michael Scott
DHDavid A. Hart
David A. Hart
NSNigel G. Shrive
Nigel G. Shrive

13 April 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
YLYizhao Li
Yizhao Li
PVParis Vakiel
Paris Vakiel
KAKevin Adanty
Kevin Adanty
SOSimon Ouellet
Simon Ouellet
Albert VetteAlbert Vette
Albert Vette
CDChristopher R. Dennison
Christopher R. Dennison

24 April 2023 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
YLYizhao Li
Yizhao Li
PVParis Vakiel
Paris Vakiel
KAKevin Adanty
Kevin Adanty
SOSimon Ouellet
Simon Ouellet
Albert VetteAlbert Vette
Albert Vette
CDChristopher R. Dennison
Christopher R. Dennison

17 October 2020 in Osteoarthritis and Cartilage Open
Verified
Journal Article
Open access
PVParis Vakiel
Paris Vakiel
MSMehdi Shekarforoush
Mehdi Shekarforoush
CDChristopher R. Dennison
Christopher R. Dennison
YAYamini Achari
Yamini Achari
GMGregory Muench
Gregory Muench
NSNigel G. Shrive
Nigel G. Shrive
There is a high risk of developing osteoarthritis (OA) following traumatic injury to the knee. Severe ligament injuries can disrupt the integrity of the multicomponent knee at both biological and biomechanical levels. We hypothesize changes in cartilages stresses could lead to tissue damage and development of OA. The in-vivo gait kinematics of the stifle (knee) joint of four adult female ovine subjects were recorded prior to and at ten-and-twenty weeks following partial ACL-MCL transection. The subjects were sacrificed and the experimental joint from each subject was mounted on a parallel robotic system programmed with the kinematic findings. Ten custom-built Fibre Bragg Grating optic sensors were arranged to measure contact stresses on the surface of the tibial plateau articular cartilage. These sensors provide the first accurate stress measurements in a joint during gait replication using the previously recorded in-vivo kinematics. The relationship between the results obtained and observed focal damage was assessed. The locations on the tibial plateaus that experienced the greatest change in contact stresses corresponded with the locations of focal damage development. No direct link was detected between individual animal differences in kinematics and variations in stress magnitudes or the development of focal cartilage damage. The findings highlight the importance of mechanical stress determinants in the integrated set point for the knee (with individual variation), and how injury-related stress changes correlate with development of PTOA.