Lisa Gades

Lisa Gades

Auto-generated profile, based on publicly available information

Lisa Gades

Argonne National Laboratory, Lemont, IL, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2024 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
VKVeenavee Nipunika Kothalawala
Veenavee Nipunika Kothalawala
TGTejas Guruswamy
Tejas Guruswamy
OQOrlando Quaranta
Orlando Quaranta
UPUmeshkumar Manibhai Patel
Umeshkumar Manibhai Patel
LGLisa Gades
Lisa Gades
Bernardo BarbielliniBernardo Barbiellini
Bernardo Barbiellini
Our Compton profile measurements of Ti and TiH2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

12 April 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Open access
DYDaikang Yan
Daikang Yan
LGLisa M. Gades
Lisa M. Gades
TGTejas Guruswamy
Tejas Guruswamy
UPUmeshkumar M. Patel
Umeshkumar M. Patel
OQOrlando Quaranta
Orlando Quaranta
AMAntonino Miceli
Antonino Miceli
Transition-edge sensors (TES) are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scattering and diffraction measurements. In particular, Compton scattering provides information about the electron momentum distribution, while energy dispersive diffraction provides structural information about dense engineering materials. Compton scattering and energy dispersive diffraction experiments must be conducted in the very hard X-ray regime (~100 keV), demanding a high X-ray stopping power in the detector; therefore, an absorber with a large heat capacity is needed in conjunction with the TES. In addition, both applications would benefit from an array composed of parallel strips. We present a design for a TES X-ray microcalorimeter optimized for such applications. In particular, we model the longitudinal position dependence due to the finite thermal diffusion time in the absorber.

23 March 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
TGTejas Guruswamy
Tejas Guruswamy
OQOrlando Quaranta
Orlando Quaranta
DRDanielle Riekse
Danielle Riekse
JPJad Panjaitan
Jad Panjaitan
LGLisa Gades
Lisa Gades
AMAntonino Miceli
Antonino Miceli
Soft X-ray resonant scattering is a sensitive probe of electronic, magnetic, and orbital order, but its weak signals are often embedded in substantial elastic, inelastic, and fluorescence backgrounds. In order to enable new science at the Advanced Photon Source (APS) X-ray synchrotron, we have developed a transition edge sensor array-based spectrometer instrument optimized for energy-resolved detection in the 0.2 to 2keV band, sustained operation at elevated photon count rates, and a mechanical design that allows for a small sensor–sample distance without interfering with existing hardware. The newly fabricated 256-pixel sensor array consists of sidecar Mo/Au transition edge sensors with Bi/Au absorbers, packaged onto a microsnout platform with frequency multiplexed $\mu$Mux readout. We report on laboratory characterization of this array prior to final instrument integration and beamline deployment. DC current–voltage measurements establish acceptable uniformity and yield but identify a higher than intended bilayer critical temperature. Readout characterization shows the majority of $\mu$Mux channels operating in a regime compatible with TESlimited energy resolution. Soft Xray spectral measurements using a lab X-ray source demonstrate a fullwidthathalfmaximum energy resolution median across the array of 2.3eV at Al K$\alpha$ (1.5keV), with almost 80% of all pixels producing spectra with resolution below 3eV. The larger than targeted energy resolution is primarily attributed to a reduced resistance sensitivity to temperature ($\alpha$) relative to the prototype designs. Overall the results indicate the spectrometer meets the minimum requirements for resonant soft X-ray scattering and related measurements at the APS. Immediate next steps focus on commissioning of the instrument at the beamline, validation of high countrate operation, and establishment of energy calibration and data analysis workflows tailored to soft X-ray science.