6 November 2017 in Applied Physics Letters
Transition-edge sensors (TESs) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stopping power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that the bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.
29 January 2016 in Journal of Low Temperature Physics
27 May 2024 in Applied Physics Letters
Our Compton profile measurements of Ti and TiH2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.
18 February 2021 in IEEE Transactions on Applied Superconductivity
Arrays of superconducting transition-edge sensor (TES) microcalorimeters are attractive for some X-ray experiments where the combination of higher collection efficiency than crystal spectrometers and much better energy resolution than semiconductor detectors is enabling. For hard X-ray (>2 keV) applications, a TES is often integrated with an extra absorber to extend its dynamic range, quantum efficiency and collecting area. For >100 keV applications, millimeter size absorbers have been manually attached to TES pixels after fabrication. At lower energies, the absorber size needs to be much smaller, because a large heat capacity degrades energy resolution. In that case, the absorber is directly electroplated or evaporated on the TES during the fabrication process. In this work, we present TES microcalorimeters optimized for the intermediate hard X-ray energy region (20 keV ∼ 100 keV) that have thick absorbers directly deposited during the TES fabrication process. This microcalorimeter is designed to measure high-resolution muonic atom transition X-ray spectra as a method to study quantum electrodynamics (QED) effects. The absorber is comprised of evaporated gold and electroplated bismuth layers and is designed to optimize dynamic range, collecting efficiency, and energy resolution in the 20 keV to 45 keV energy range. A prototype with pure gold absorbers has been fabricated and characterized, in order to obtain a first experimental reference in the detector development process.
26 September 2022 in Journal of Low Temperature Physics
12 April 2019 in IEEE Transactions on Applied Superconductivity
Transition-edge sensors (TES) are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scattering and diffraction measurements. In particular, Compton scattering provides information about the electron momentum distribution, while energy dispersive diffraction provides structural information about dense engineering materials. Compton scattering and energy dispersive diffraction experiments must be conducted in the very hard X-ray regime (~100 keV), demanding a high X-ray stopping power in the detector; therefore, an absorber with a large heat capacity is needed in conjunction with the TES. In addition, both applications would benefit from an array composed of parallel strips. We present a design for a TES X-ray microcalorimeter optimized for such applications. In particular, we model the longitudinal position dependence due to the finite thermal diffusion time in the absorber.