24 February 2019 in IEEE Transactions on Sustainable Energy
Penetration of renewable energy sources (RESs) and electrical energy storage (EES) systems in distribution systems is increasing, and it is crucial to investigate their impact on systems' operation scheme, reliability, and security. In this paper, expected energy not supplied (EENS) and voltage stability index (VSI) of distribution networks are investigated in dynamic balanced and unbalanced distribution network reconfiguration, including RESs and EES systems. Furthermore, due to the high investment cost of the EES systems, the number of charge and discharge is limited, and the state-of-health constraint is included in the underlying problem to prolong the lifetime of these facilities. The optimal charging/discharging scheme for EES systems and optimal distribution network topology are presented in order to optimize the operational costs, and reliability and security indices simultaneously. The proposed strategy is applied to a large-scale 119-bus distribution test network in order to show the economic justification of the proposed approach.
25 January 2019 in IEEE Transactions on Sustainable Energy
26 June 2017 in Engineering Optimization
This article proposes an efficient improved hybrid Jaya algorithm based on time-varying acceleration coefficients (TVACs) and the learning phase introduced in teaching–learning-based optimization (TLBO), named the LJaya-TVAC algorithm, for solving various types of nonlinear mixed-integer reliability–redundancy allocation problems (RRAPs) and standard real-parameter test functions. RRAPs include series, series–parallel, complex (bridge) and overspeed protection systems. The search power of the proposed LJaya-TVAC algorithm for finding the optimal solutions is first tested on the standard real-parameter unimodal and multi-modal functions with dimensions of 30–100, and then tested on various types of nonlinear mixed-integer RRAPs. The results are compared with the original Jaya algorithm and the best results reported in the recent literature. The optimal results obtained with the proposed LJaya-TVAC algorithm provide evidence for its better and acceptable optimization performance compared to the original Jaya algorithm and other reported optimal results.
1 July 2018 in Computers and Electrical Engineering
SSSamaneh Fathi Sasansara
22 March 2018 in IEEE Systems Journal
This paper introduces various models for optimal and maximal utility-based distributed generation penetration in the radial distribution systems. Several problems with different probabilistic indices as objective functions constrained by power flow equations, distributed generation penetration, voltage, and thermal limits are proposed to obtain the optimal penetration of distributed generations on rural distribution networks. There are tradeoffs between interests and risks that the distribution network operators or distribution companies may be willing to take on. Thus, to have an effective method for maximal allocation of distributed generations, new indices are proposed, and the problems are formulated as a risk-constrained optimization model. The obtained problems have mixed-integer nonlinear programming and nonconvex forms because of nonlinearity and nonconvexity of the optimal power flow (OPF) equations and indices, leading to computationally nondeterministic polynomial-time-hard problems. Accordingly, in this paper, convex relaxations of OPF are introduced instead of the conventional nonlinear equations. Efficient linear equivalents of the objective function and constraints are introduced to reduce the computational burden. Test results of the proposed models on a radial distribution system are presented and discussed.
20 January 2020 in IEEE Transactions on Smart Grid
Large-scale compressed air energy storage (CAES) is conventionally used in power systems. However, application of CAESs at the distribution level is limited because of differences in design and efficiency. On the other hand, application of electrical batteries suited for distribution networks (DNs) faces also challenges from high investment cost and significant degradation. In this regard, this paper presents the participation of an active distribution system equipped with a small-scale CAES (SCAES) in the day-ahead wholesale market. To make CAES applicable to DNs, thermalelectrical setting design of the SCAES coupled with a packed-bed heat exchanger is adopted in the operation of the grid, where SCAES performs as an energy storage for DNs to surpass existing deficiencies of battery banks. The electrical/thermal conversion rate has been modeled for the SCAES operation. Moreover, the operation strategy of the SCAES is optimally coordinated with an electric vehicle charging station (EVCS) as an alternative energy storage technology in deregulated DNs. To make EVCS simulation more realistic, Gaussian Copula probability distribution function is used to model the behavior of the EVCS. The results obtained from different case studies confirm the value of SCAES as a reliable energy storage technology for DNs.