This paper investigates the risk-oriented multi-area economic dispatch (MAED) problem with high penetration of wind farm (WF) combined with compressed air energy storage (CAES). The main objective is to help system operators to minimize the operational cost of thermal units and CAES units with an appropriate level of security through optimized WF power generation error curtailment strategy and CAES charging/discharging control. In the obtained MAED model, several WFs integrated with CAES units are considered in different generation zones, and the probability to meet demand by available spinning reserves during N-1 security contingency is characterized as a risk function. Furthermore, the contribution of CAES units in providing the system spinning reserve is taken into account in the MAED model, which accounts for another noteworthy feature of this study. The proposed framework is demonstrated by a case study using the modified IEEE 40-generator system. The numerical results reveal that the proposed method brings a significant advantage to the efficient scheduling of thermal units' power generation, WF power curtailment and CAES charging/discharging control in the power system.
1 July 2018 in Computers and Electrical Engineering
With the advent of restructuring in the power industry, the conventional unit commitment problem in power systems, involving the minimization of operation costs in a traditional vertically integrated system structure, has been transformed to the profit-based unit commitment (PBUC) approach, whereby generation companies (GENCOs) perform scheduling of the available production units with the aim of profit maximization. Generally, a GENCO solves the PBUC problem for participation in the day-ahead market (DAM) through determining the commitment and scheduling of fossil-fuel-based units to maximize their own profit according to a set of forecasted price and load data. This study presents a methodology to achieve optimal offering curves for a price-taker GENCO owning compressed air energy storage (CAES) and concentrating solar power (CSP) units, in addition to conventional thermal power plants. Various technical and physical constraints regarding the generation units are considered in the provided model. The proposed framework is mathematically described as a mixed-integer linear programming (MILP) problem, which is solved by using commercial software packages. Meanwhile, several cases are analyzed to evaluate the impacts of CAES and CSP units on the optimal solution of the PBUC problem. The achieved results demonstrate that incorporating the CAES and CSP units into the self-scheduling problem faced by the GENCO would increase its profitability in the DAM to a great extent.
20 January 2020 in IEEE Transactions on Smart Grid
Large-scale compressed air energy storage (CAES) is conventionally used in power systems. However, application of CAESs at the distribution level is limited because of differences in design and efficiency. On the other hand, application of electrical batteries suited for distribution networks (DNs) faces also challenges from high investment cost and significant degradation. In this regard, this paper presents the participation of an active distribution system equipped with a small-scale CAES (SCAES) in the day-ahead wholesale market. To make CAES applicable to DNs, thermalelectrical setting design of the SCAES coupled with a packed-bed heat exchanger is adopted in the operation of the grid, where SCAES performs as an energy storage for DNs to surpass existing deficiencies of battery banks. The electrical/thermal conversion rate has been modeled for the SCAES operation. Moreover, the operation strategy of the SCAES is optimally coordinated with an electric vehicle charging station (EVCS) as an alternative energy storage technology in deregulated DNs. To make EVCS simulation more realistic, Gaussian Copula probability distribution function is used to model the behavior of the EVCS. The results obtained from different case studies confirm the value of SCAES as a reliable energy storage technology for DNs.
The presence of electrical energy storage (EES) units in distribution systems has potentials to improve the network profiles (e.g. bus voltage and branch current profiles) as well as to reduce operational cost and power losses. This paper presents a novel approach to determine the optimal charging/discharging schedule of EES units in distribution systems by employing multi-objective optimization methods, aiming at reducing operation cost and enhancing radial distribution networks security. In this regard, a voltage stability index (VSI) to improve the radial network security is presented as a separate objective function. In order to assess effectiveness and applicability of the proposed method, it is applied to a 33-bus IEEE standard distribution test system and then the obtained results are compared with existing methodologies.