11 April 2023 in Optics Express
Conventional (CP) and Fourier (FP) ptychography have emerged as versatile quantitative phase imaging techniques. While the main application cases for each technique are different, namely lens-less short wavelength imaging for CP and lens-based visible light imaging for FP, both methods share a common algorithmic ground. CP and FP have in part independently evolved to include experimentally robust forward models and inversion techniques. This separation has resulted in a plethora of algorithmic extensions, some of which have not crossed the boundary from one modality to the other. Here, we present an open source, cross-platform software, called PtyLab, enabling both CP and FP data analysis in a unified framework. With this framework, we aim to facilitate and accelerate cross-pollination between the two techniques. Moreover, the availability in Matlab, Python, and Julia will set a low barrier to enter each field.
18 January 2024 in Optics Express
Structured illumination is essential for high-performance ptychography. Especially in the extreme ultraviolet (EUV) range, where reflective optics are prevalent, the generation of structured beams is challenging and, so far, mostly amplitude-only masks have been used. In this study, we generate a highly structured beam using a phase-shifting diffuser optimized for 13.5 nm wavelength and apply this beam to EUV ptychography. This tailored illumination significantly enhances the quality and resolution of the ptychography reconstructions. In particular, when utilizing the full dynamics range of the detector, the resolution has been improved from 125 nm, when using an unstructured beam, to 34 nm. Further, ptychography enables the quantitative measurement of both the amplitude and phase of the EUV diffuser at 13.5 nm wavelength. This capability allows us to evaluate the influence of imperfections and contaminations on its “at wavelength” performance, paving the way for advanced EUV metrology applications and highlighting its importance for future developments in nanolithography and related fields.
14 April 2023 in Optics Express
We present high-speed and wide-field EUV ptychography at 13.5 nm wavelength using a table-top high-order harmonic source. Compared to previous measurements, the total measurement time is significantly reduced by up to a factor of five by employing a scientific complementary metal oxide semiconductor (sCMOS) detector that is combined with an optimized multilayer mirror configuration. The fast frame rate of the sCMOS detector enables wide-field imaging with a field of view of 100 µm × 100 µm with an imaging speed of 4.6 Mpix/h. Furthermore, fast EUV wavefront characterization is employed using a combination of the sCMOS detector with orthogonal probe relaxation.
1 May 2025 in APL Photonics
Short-wavelength radiation in the extreme ultraviolet (XUV) and soft x-ray spectral regions offers unique advantages for imaging. With wavelengths ranging from a few nanometers to a few tens of nanometers, these techniques enable spatial resolutions at the nanometer scale. In addition, penetration depths in solids in this spectral regime enable non-destructive imaging of internal structures of micrometer-thick objects, surpassing the capabilities of electron microscopy. Furthermore, the diverse atomic absorption edges characteristic of this spectral region enable high-contrast imaging without any staining or labeling. When combined with quantitative phase-sensitive imaging techniques, even material identification at the nanoscale becomes feasible. This article reviews some of the latest advancements in the field. It provides an overview of the available tabletop sources in this spectral region and discusses concepts and state-of-the-art results of two complementary imaging techniques: XUV ptychography and XUV coherence tomography. While XUV ptychography achieves nanoscale lateral resolution, XUV coherence tomography enables nanoscale axial resolution. Both techniques allow for the non-destructive mapping of the chemical composition of samples, facilitating localized analysis of material compositions in integrated circuits or microorganisms. The article also presents a perspective on future developments in time-resolved and 3D XUV imaging and potential future application fields.
19 July 2024 in Optics Express
The limited dynamic range of the detector can impede coherent diffractive imaging (CDI) schemes from achieving diffraction-limited resolution. To overcome this limitation, a straightforward approach is to utilize high dynamic range (HDR) imaging through multi-exposure image fusion (MEF). This method involves capturing measurements at different exposure times, spanning from under to overexposure and fusing them into a single HDR image. The conventional MEF technique in ptychography typically involves subtracting the background noise, ignoring the saturated pixels and then merging the acquisitions. However, this approach is inadequate under conditions of low signal-to-noise ratio (SNR). Additionally, variations in illumination intensity significantly affect the phase retrieval process. To address these issues, we propose a Bayesian MEF modeling approach based on a modified Poisson distribution that takes the background and saturation into account. The expectation-maximization (EM) algorithm is employed to infer the model parameters. As demonstrated with synthetic and experimental data, our approach outperforms the conventional MEF method, offering superior phase retrieval under challenging experimental conditions. This work underscores the significance of robust multi-exposure image fusion for ptychography, particularly in imaging shot-noise-dominated weakly scattering specimens or in cases where access to HDR detectors with high SNR is limited. Furthermore, the applicability of the Bayesian MEF approach extends beyond CDI to any imaging scheme that requires HDR treatment. Given this versatility, we provide the implementation of our algorithm as a Python package.
24 February 2025 in Optics Letters
Calibration of ptychographic setup properties, such as the sample-detector axial distance, is crucial for quantitative and high-resolution reconstructions. This study proposes a calibration scheme based on the degree of coherence (i.e., purity) of the probe in mixed-state ptychography. Compared to established sharpness metric-based methods, it is significantly more robust and applicable to arbitrary samples. A numerical study and validations with various experimental datasets have been conducted to verify the performance of the proposed method, including the application to high-contrast samples and weakly-scattering biological samples. This calibration scheme can significantly enhance the image quality, the precision of wavefront sensing, and the reliability of quantitative analysis for ptychography. Potentially, we believe this optimization method can find further applications in other areas of computational imaging.