Ran Zhang

Ran Zhang

Auto-generated profile, based on publicly available information

Ran Zhang

Univ. of Wisconsin School of Medicine and Public Health (United States)

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
EHEvan Cary Harvey
Evan Cary Harvey
MFMang Feng
Mang Feng
XJXu Ji
Xu Ji
RZRan Zhang
Ran Zhang
YLYinsheng Li
Yinsheng Li
KLKe Li
Ke Li
While CTA is an established clinical gold standard for imaging large cerebral arteries and veins, an important challenge that currently remains for CTA is its limited performance in imaging small perforating arteries with diameters below 0.5 mm. The purpose of this work was to theoretically and experimentally study the potential benefits of using photon counting detector (PCD)-based CT (PCCT) to improve the performance of CTA in imaging these small arteries. In particular, the study focused on an important component of the CTA image package known as the maximum intensity projection (MIP) image. To help understand how the physical properties of a detector quantitatively influence the MIP image quality, a theoretical model on the statistical properties of MIP images was developed. After validating this model, it was used to explore the individual and joint contribution of the following detector properties to the MIP signal-to-noise ratio (SNR): inter-slice noise covariance, spatial resolution along the z direction, and native pixel pitch along z . The model demonstrated that superior slice sensitivity, reduced inter-slice noise correlation, and smaller native pixel pitch along z provided by PCDs lead to improved vessel SNR in MIP images. Finally, experiments were performed by scanning an anthropomorphic cerebral angiographic phantom using a benchtop PCCT system and a commercial MDCT system. The experimental MIP results consistently demonstrated that compared with MDCT, PCCT provides superior vessel conspicuity and reduced artifactual stenosis.

10 December 2021 in Frontiers in Oncology
Verified
Journal Article
Open access
CZChengzhou Zhang
Chengzhou Zhang
QYQinglin Yang
Qinglin Yang
FLFan Lin
Fan Lin
HMHeng Ma
Heng Ma
HZHaicheng Zhang
Haicheng Zhang
NMNing Mao
Ning Mao
Objectives: This study aimed to distinguish preoperatively anterior mediastinal thymic cysts from thymic epithelial tumors via a computed tomography (CT)-based radiomics nomogram.Methods: This study analyzed 74 samples of thymic cysts and 116 samples of thymic epithelial tumors as confirmed by pathology examination that were collected from January 2014 to December 2020. Among the patients, 151 cases (scanned at CT 1) were selected as the training cohort, and 39 cases (scanned at CT 2 and 3) served as the validation cohort. Radiomics features were extracted from pre-contrast CT images. Key features were selected by SelectKBest and least absolute shrinkage and selection operator and then used to build a radiomics signature (Rad-score). The radiomics nomogram developed herein via multivariate logistic regression analysis incorporated clinical factors, conventional CT findings, and Rad-score. Its performance in distinguishing the samples of thymic cysts from those of thymic epithelial tumors was assessed via discrimination, calibration curve, and decision curve analysis (DCA).Results: The radiomics nomogram, which incorporated 16 radiomics features and 3 conventional CT findings, including lesion edge, lobulation, and CT value, performed better than Rad-score, conventional CT model, and the clinical judgment by radiologists in distinguishing thymic cysts from thymic epithelial tumors. The area under the receiver operating characteristic (ROC) curve of the nomogram was 0.980 [95% confidence interval (CI), 0.963–0.993] in the training cohort and 0.992 (95% CI, 0.969–1.000) in the validation cohort. The calibration curve and the results of DCA indicated that the nomogram has good consistency and valuable clinical utility.Conclusion: The CT-based radiomics nomogram presented herein may serve as an effective and convenient tool for differentiating thymic cysts from thymic epithelial tumors. Thus, it may aid in clinical decision-making.

28 May 2020 in Medical Physics
Verified
Journal Article
Open access
PDF file
RZRan Zhang
Ran Zhang
AFAmy Fowler
Amy Fowler
LWLee G. Wilke
Lee G. Wilke
FKFrederick Kelcz
Frederick Kelcz
JGJohn Garrett
John Garrett
KLKe Li
Ke Li
Purpose A major technical obstacle to bringing x‐ray multicontrast (i.e., attenuation, phase, and dark‐field) imaging methodology to clinical use is the prolonged data acquisition time caused by the phase stepping procedure. The purpose of this work was to introduce a fast acquisition with seamless stage translation (FASST) technique to a prototype multicontrast breast imaging system for reduced image acquisition time that is clinically acceptable. Methods The prototype system was constructed based on a Hologic full‐field digital mammography + digital breast tomosynthesis combination system. During each FASST acquisition process, a motorized stage holding a diffraction grating travels continuously with a constant velocity, and a train of 15 short x‐ray pulses (35 ms each) was delivered by using the Zero‐Degree Tomo mode of the Hologic system. Standard phase retrieval was applied to the 15 subimages without spatial interpolation to avoid spatial resolution loss. The method was evaluated using a physical phantom, a bovine udder specimen, and a freshly resected mastectomy specimen. The FASST technique was experimentally compared with single‐shot acquisition methods and the standard phase stepping method. Results The image acquisition time of the proposed method is 3.7 s. In comparison, conventional phase stepping took 105 s using the same prototype imaging system. The mean glandular dose of both methods was matched at 1.3 mGy. No artifacts or spatial resolution loss was observed in images produced by FASST. In contrast, the single‐shot methods led to spatial resolution loss and residual moiré artifacts. Conclusions The FASST technique reduces the data acquisition time of the prototype multicontrast x‐ray breast imaging system to 3.7 s, such that it is comparable to a clinical digital breast tomosynthesis exam.

16 March 2020 in Proceedings of SPIE
Verified
Conference Paper
Open access
PDF file
XJXu Ji
Xu Ji
RZRan Zhang
Ran Zhang
KLKe Li
Ke Li
GCGuang-Hong Chen
Guang-Hong Chen
Three-material decomposition is crucial for material quantification when more than two elemental materials, including a K-edge material, are presented in an image object. In principle, three-material decomposition requires a triple energy scan which cannot be directly accomplished using a conventional dual energy CT system. In this work, a new scheme to enable three-material decomposition by employing phase contrast CT was presented. When a grating interferometer is added, a conventional absorption dual energy CT system can be upgraded to a phase contrast dual energy CT system which provides an additional phase signal related to the real part of the refractive index of an image object, along with the absorption signal under two different x-ray spectra. In this work, a three-material decomposition method was proposed for the aforementioned dual energy phase contrast CT system. Physical experimental studies were performed on a benchtop x-ray Talbot-Lau interferometer system to validate the proposed method. A physical phantom, containing calcium and iodine inserts of known concentrations, was used as the image object. A rotation-rotation dual energy phase contrast CT scan was performed under 40 and 80 kVp tube potentials. For each view angle, a phase stepping procedure with five phase steps was performed. After the phase retrieval procedure and image reconstruction using the standard filtered-back projection, the solutions were decomposed into the calcium, iodine and water bases based on the proposed decomposition method. For all the solutions, the relative quantification errors of the concentrations were within 10%.

9 September 2022 in Gynecologic Oncology
Verified
Journal Article
Closed access
RZRan Zhang
Ran Zhang
TSTaylor Stewart
Taylor Stewart
KTKaitlin Tetreault
Kaitlin Tetreault
RARoxana Alexandridis
Roxana Alexandridis
JBJason Bergsbaken
Jason Bergsbaken
EHEllen Hartenbach
Ellen Hartenbach

16 April 2021 in arXiv
Verified
Preprint
Open access
PDF file
STSaeid Asgari Taghanaki
Saeid Asgari Taghanaki
JLJieliang Luo
Jieliang Luo
RZRan Zhang
Ran Zhang
YWYe Wang
Ye Wang
PJPradeep Kumar Jayaraman
Pradeep Kumar Jayaraman
KJKrishna Murthy Jatavallabhula
Krishna Murthy Jatavallabhula
The 3D deep learning community has seen significant strides in pointcloud processing over the last few years. However, the datasets on which deep models have been trained have largely remained the same. Most datasets comprise clean, clutter-free pointclouds canonicalized for pose. Models trained on these datasets fail in uninterpretible and unintuitive ways when presented with data that contains transformations "unseen" at train time. While data augmentation enables models to be robust to "previously seen" input transformations, 1) we show that this does not work for unseen transformations during inference, and 2) data augmentation makes it difficult to analyze a model's inherent robustness to transformations. To this end, we create a publicly available dataset for robustness analysis of point cloud classification models (independent of data augmentation) to input transformations, called RobustPointSet. Our experiments indicate that despite all the progress in the point cloud classification, there is no single architecture that consistently performs better -- several fail drastically -- when evaluated on transformed test sets. We also find that robustness to unseen transformations cannot be brought about merely by extensive data augmentation. RobustPointSet can be accessed through https://github.com/AutodeskAILab/RobustPointSet.