Edwin Bennink

Edwin Bennink

Auto-generated profile, based on publicly available information

Edwin Bennink

Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
FOF. van Ommen
F. van Ommen
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
JDJan Willem Dankbaar
Jan Willem Dankbaar
EBE. Bennink
E. Bennink
TLT. Leiner
T. Leiner
ASA.M.R. Schilham
A.M.R. Schilham

29 July 2020 in Neuroradiology
Verified
Journal Article
Open access
PDF file
FOFasco van Ommen
Fasco van Ommen
JDJan Willem Dankbaar
Jan Willem Dankbaar
GZGuangming Zhu
Guangming Zhu
DWDylan N. Wolman
Dylan N. Wolman
JHJeremy J. Heit
Jeremy J. Heit
MWMax Wintermark
Max Wintermark
Purpose: Early infarcts are hard to diagnose on non-contrast head CT. Dual-energy CT (DECT) may potentially increase infarct differentiation. The optimal DECT settings for differentiation were identified and evaluated. Methods: One hundred and twenty-five consecutive patients who presented with suspected acute ischemic stroke (AIS) and underwent non-contrast DECT and subsequent DWI were retrospectively identified. The DWI was used as reference standard. First, virtual monochromatic images (VMI) of 25 patients were reconstructed from 40 to 140 keV and scored by two readers for acute infarct. Sensitivity, specificity, positive, and negative predictive values for infarct detection were compared and a subset of VMI energies were selected. Next, for a separate larger cohort of 100 suspected AIS patients, conventional non-contrast CT (NCT) and selected VMI were scored by two readers for the presence and location of infarct. The same statistics for infarct detection were calculated. Infarct location match was compared per vascular territory. Subgroup analyses were dichotomized by time from last-seen-well to CT imaging. Results: A total of 80–90 keV VMI were marginally more sensitive (36.3–37.3%) than NCT (32.4%; p > 0.680), with marginally higher specificity (92.2–94.4 vs 91.1%; p > 0.509) for infarct detection. Location match was superior for VMI compared with NCT (28.7–27.4 vs 19.5%; p < 0.010). Within 4.5 h from last-seen-well, 80 keV VMI more accurately detected infarct (58.0 vs 54.0%) and localized infarcts (27.1 vs 11.9%; p = 0.004) than NCT, whereas after 4.5 h, 90 keV VMI was more accurate (69.3 vs 66.3%). Conclusion: Non-contrast 80–90 keV VMI best differentiates normal from infarcted brain parenchyma.

21 January 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
AHA. D. Horsch
A. D. Horsch
JDJan Willem Dankbaar
Jan Willem Dankbaar
TST. A. Stemerdink
T. A. Stemerdink
EBE. Bennink
E. Bennink
TST. van Seeters
T. van Seeters
OIon behalf of the DUST investigators
on behalf of the DUST investigators
BACKGROUND AND PURPOSE: Prominent space-occupying cerebral edema is a devastating complication occurring in some but not all patients with large MCA infarcts. It is unclear why differences in the extent of edema exist. Better knowledge of factors related to prominent edema formation could aid treatment strategies. This study aimed to identify variables associated with the development of prominent edema in patients with large MCA infarcts. MATERIALS AND METHODS: From the Dutch Acute Stroke Study (DUST), 137 patients were selected with large MCA infarcts on follow-up NCCT (3 ± 2 days after stroke onset), defined as ASPECTS ≤4. Prominent edema was defined as a midline shift of ≥5 mm on follow-up. Admission patient and treatment characteristics were collected. Admission CT parameters used were ASPECTS on NCCT and CBV and MTT maps, and occlusion site, clot burden, and collaterals on CTA. Permeability on admission CTP, and day 3 recanalization and reperfusion statuses were obtained if available. Unadjusted and adjusted (age and NIHSS) odds ratios were calculated for all variables in relation to prominent edema. RESULTS: Prominent edema developed in 51 patients (37%). Adjusted odds ratios for prominent edema were higher with lower ASPECTS on NCCT (adjusted odds ratio, 1.32; 95% CI, 1.13–1.55) and CBV (adjusted odds ratio, 1.26; 95% CI, 1.07–1.49), higher permeability (adjusted odds ratio, 2.35; 95% CI, 1.30–4.24), more proximal thrombus location (adjusted odds ratio, 3.40; 95% CI, 1.57–7.37), higher clot burden (adjusted odds ratio, 2.88; 95% CI, 1.11–7.45), and poor collaterals (adjusted odds ratio, 3.93; 95% CI, 1.78–8.69). CONCLUSIONS: Extensive proximal occlusion, poor collaterals, and larger ischemic deficits with higher permeability play a role in the development of prominent edema in large MCA infarcts.

1 March 2023 in Stroke
Verified
Journal Article
Open access
FKFrans Kauw
Frans Kauw
BVBirgitta K Velthuis
Birgitta K Velthuis
RTRichard A P Takx
Richard A P Takx
MGMarco Guglielmo
Marco Guglielmo
MCMaarten J. M. Cramer
Maarten J. M. Cramer
JDJan Willem Dankbaar
Jan Willem Dankbaar
Background: Identifying cardioembolic sources in patients with acute ischemic stroke is important for the choice of secondary prevention strategies. We prospectively investigated the yield of admission (spectral) nongated cardiac computed tomography angiography (CTA) to detect cardioembolic sources in stroke. Methods: Participants of the ENCLOSE study (Improved Prediction of Recurrent Stroke and Detection of Small Volume Stroke) with transient ischemic attack or acute ischemic stroke with assessable nongated head-to-heart CTA at the University Medical Center Utrecht were included between June 2017 and March 2022. The presence of cardiac thrombus on cardiac CTA was based on a Likert scale and dichotomized into certainly or probably absent versus possibly, probably, or certainly present. The diagnostic certainty of cardiac thrombus was evaluated again on spectral computed tomography reconstructions. The likelihood of a cardioembolic source was determined post hoc by an expert panel in patients with cardiac thrombus on CTA. Parametric and nonparametric tests were used to compare the outcome groups. Results: Forty four (12%) of 370 included patients had a cardiac thrombus on admission CTA: 35 (9%) in the left atrial appendage and 14 (4%) in the left ventricle. Patients with cardiac thrombus had more severe strokes (median National Institutes of Health Stroke Scale score, 10 versus 4; P =0.006), had higher clot burden (median clot burden score, 9 versus 10; P =0.004), and underwent endovascular treatment more often (43% versus 20%; P <0.001) than patients without cardiac thrombus. Left atrial appendage thrombus was present in 28% and 6% of the patients with and without atrial fibrillation, respectively ( P <0.001). The diagnostic certainty for left atrial appendage thrombus was higher for spectral iodine maps compared with the conventional CTA ( P <0.001). The presence of cardiac thrombus on CTA increased the likelihood of a cardioembolic source according to the expert panel ( P <0.001). Conclusions: Extending the stroke CTA to cover the heart increases the chance of detecting cardiac thrombi and helps to identify cardioembolic sources in the acute stage of ischemic stroke with more certainty. Spectral iodine maps provide additional value for detecting left atrial appendage thrombus. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04019483.

17 April 2019 in Audiology and Neurotology
Verified
Journal Article
Open access
PDF file
JPJeroen P.M. Peters
Jeroen P.M. Peters
EBEdwin Bennink
Edwin Bennink
GZGijsbert A. van Zanten
Gijsbert A. van Zanten
Background: In electric-acoustic pitch matching experiments in patients with single-sided deafness and a cochlear implant, the observed “mismatch” between perceived pitch and predicted pitch, based on the amended Greenwood frequency map, ranges from –1 to –2 octaves. It is unknown if and how this mismatch differs for perimodiolar versus lateral wall electrode arrays. Objectives: We aimed to investigate if the type of electrode array design is of influence on the electric-acoustic pitch match. Method: Fourteen patients (n = 8 with CI422 + lateral wall electrode array, n = 6 with CI512 + perimodiolar electrode array; Cochlear Ltd.) compared the pitch of acoustic stimuli to the pitch of electric stimuli at two test sessions (average interval 4.3 months). We plotted these “pitch matches” per electrode contact against insertion angle, calculated from high-resolution computed tomography scans. The difference between these pitch matches and two references (the spiral ganglion map and the default frequency allocation by Cochlear Ltd.) was defined as “mismatch.” Results: We found average mismatches of –2.2 octaves for the CI422 group and –1.3 octaves for the CI512 group. For any given electrode contact, the mismatch was smaller for the CI512 electrode array than for the CI422 electrode array. For all electrode contacts together, there was a significant difference between the mismatches of the two groups (p < 0.05). Results remained stable over time, with no significant difference between the two test sessions considering all electrode contacts. Neither group showed a significant correlation between the mismatch and phoneme recognition scores. Conclusion: The pitch mismatch was smaller for the perimodiolar electrode array than for the lateral wall electrode array.

24 July 2013 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
EBEdwin Bennink
Edwin Bennink
ARAlan J Riordan
Alan J Riordan
AHAlexander D Horsch
Alexander D Horsch
JDJan Willem Dankbaar
Jan Willem Dankbaar
BVBirgitta K Velthuis
Birgitta K Velthuis
HJHugo W de Jong
Hugo W de Jong
Blood–brain barrier damage, which can be quantified by measuring vascular permeability, is a potential predictor for hemorrhagic transformation in acute ischemic stroke. Permeability is commonly estimated by applying Patlak analysis to computed tomography (CT) perfusion data, but this method lacks precision. Applying more elaborate kinetic models by means of nonlinear regression (NLR) may improve precision, but is more time consuming and therefore less appropriate in an acute stroke setting. We propose a simplified NLR method that may be faster and still precise enough for clinical use. The aim of this study is to evaluate the reliability of in total 12 variations of Patlak analysis and NLR methods, including the simplified NLR method. Confidence intervals for the permeability estimates were evaluated using simulated CT attenuation-time curves with realistic noise, and clinical data from 20 patients. Although fixating the blood volume improved Patlak analysis, the NLR methods yielded significantly more reliable estimates, but took up to 12 x longer to calculate. The simplified NLR method was ~4 x faster than other NLR methods, while maintaining the same confidence intervals (CIs). In conclusion, the simplified NLR method is a new, reliable way to estimate permeability in stroke, fast enough for clinical application in an acute stroke setting.