6 May 2019 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
OOOluwaseyi T. Ogunsola
Oluwaseyi T. Ogunsola
JWJunke Wang
Junke Wang
LSLi Song
Li Song
The lack of measurement data on particle generation rates from process activities for companies involved in the life sciences industry, such as pharmaceutical and biotechnology firms, has the potential to undermine cleanroom design, particulate concentration control, and energy efficiency. Based on this situation, this paper surveys the particle production rates from process activities in pharmaceutical and biological cleanrooms using field measurements for the particle sizes of interest (0.3 µm, 0.5 µm, and 1 µm). The measured and collected data were correlated to the surveyed activities to obtain a range of particle generation rates for different cleanroom operations. In terms of the recommended ACH values and measured ACH values, the results indicate that although most cleanrooms operate below the recommended ranges, in most cases they satisfy or exceed the required ISO standard cleanliness levels. In addition, the particle generation rates are process-specific and that suggests process-specific guidelines for different cleanrooms will help engineers, owners and contractors arrive at a better design solution. It is worth mentioning that nonperfect mixing of airflow and particles was observed in several cleanrooms, resulting in large variances in the measurements at different sampling locations. This observation suggests that a correction factor might be needed for the ventilation effectiveness for Class 7 and 8 cleanrooms. Although the determination of the correction factor is beyond the study of this paper, the data presented in this paper are critical to understand the severity of the non-perfect mixing in Class 7 and 8 cleanrooms and thus provides insights on the determination of the correction factor. The research reported in this paper was conducted through the ASHRAE 1399 research project, with a focus on developing scientific cleanroom design guidelines that can assist engineers, owners, and contractors to arrive at appropriately sized and efficient cleanroom systems.

7 August 2014 in HVAC&R Research
Verified
Journal Article
Closed access
JHJunjun Hu
Junjun Hu
OOOluwaseyi T. Ogunsola
Oluwaseyi T. Ogunsola
LSLi Song
Li Song
RMRenee A. McPherson
Renee A. McPherson
MZMeijun Zhu
Meijun Zhu
SCSheng Chen
Sheng Chen
Building energy system retrofit and retro-commissioning projects present tremendous opportunities to save energy. Energy consumption in buildings, especially HVAC systems, is significantly impacted by weather conditions. However, short- or long-term climatic data are frequently missing because of data transmission problems, data quality assurance methods, sensor malfunction, or a host of other reasons. These gaps in climatic data continue to provide challenges for HVAC engineers in monitoring and verifying building energy performance. This article examines eight classical approaches that use Linear interpolation, Lagrange interpolation, and Cubic Spline interpolation techniques, and eleven approaches that use two newly developed methods, i.e., Angle-based interpolation and Corr-based interpolation, to restore up to 24 h of missing dry-bulb temperature data in a time series for use in building performance monitoring and analysis. Eleven one-year hourly data sets are used to evaluate the performance of these 19 different methods. Each method is applied to deal with artificial gaps that are generated randomly. In terms of the difference between estimated values and measured values, two types of comparisons are carried out. The first comparison is conducted with three evaluation indices: MAE, RMSE, and STDBIAS. The second comparison is based on the percentage of the total data that can be estimated by an approach within specific error thresholds, including 1°F (0.56°C), 2°F (1.11°C), 3°F (1.67°C), and 5°F (2.78°C), from measured values. The comparison results show that Linear interpolation performs best when filling 1–2 h gaps, Lagrange interpolation (Lag2L2R) outperforms other methods when gaps are 3–8 h long, and the Corr-based interpolation method (Corr1L1R24Avg) is a better technique for filling 9–24 h gaps. This article presents the first part of the research results through the ASHRAE 1413 research project. The second part of the results focuses on methods to filling long-term dry-bulb temperature gaps.

8 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
GWGang Wang
Gang Wang
Junke WangJunke Wang
Junke Wang
NTNurayn Tiamiyu
Nurayn Tiamiyu
Zufen WangZufen Wang
Zufen Wang
LSLi Song
Li Song
An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.

4 April 2012 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
LSLi Song
Li Song
IJIk-Seong Joo
Ik-Seong Joo
SGSubroto Gunawan
Subroto Gunawan
Thermal storage systems were originally designed to shift on-peak cooling production to off-peak cooling production in order to reduce on-peak electricity demand. Recently, however, the reduction of both on- and off-peak demand is a critical issue. Reduction of on- and off-peak demand can also extend the life span and defer or eliminate the replacement of power transformers. Next day electricity consumption is a critical set point to operate chillers and associated pumps at the appropriate time. In this paper, a data evaluation process using the annual daily average cooling consumption of a building was conducted. Three real-time building load forecasting models were investigated: a first-order autoregressive model (AR(1)), an autogressive integrated moving average model (ARIMA(0,1,0)), and a linear regression model. A comparison of results shows that the AR(1) and ARIMA(0,1,0) models provide superior results to the linear regression model, except that the AR(1) model has a few unacceptable spikes. A complete control algorithm integrated with a corrected AR(1) forecast model for a chiller plant including chillers, thermal storage system, and pumping systems was developed and implemented to verify the feasibility of applying this algorithm in the building automation system. Application results are also introduced in the paper.

28 January 2016 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
OOOluwaseyi Ogunsola
Oluwaseyi Ogunsola
LSLi Song
Li Song
YWYing Wang
Ying Wang
Heating and cooling load calculations are critical to size HVAC systems and determine energy use of their operations. The ASHRAE recommended heating load calculation model is most commonly used for heating load calculations. It adopts a simplified approach by considering only steady-state conductive heat transfer. However, due to thermal storage effect, heat generated in daytime may still be stored in buildings and released at a later time. Such assumption leads to significantly over-sized heating systems which are usually accompanied by high initial cost and higher cost of energy use. This study therefore examines the thermal response and passive storage characteristic of heavy construction for typical office building in continental United States. By allowing space air to drift to reasonably lower values, buildings need to be warmed up before being occupied in the morning. The worst case conditions might happen during warm-up or beginning of occupied hours. This article evaluates the optimal size of heating system which satisfies thermal comfort while taking advantage of passive thermal storage. Results show varying downsizing opportunities ranging from 14% to 54% across the United States. These results have the potential of establishing new heating device design standards for certain climate classifications.

13 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
GWGang Wang
Gang Wang
Junke WangJunke Wang
Junke Wang
NTNurayn Tiamiyu
Nurayn Tiamiyu
Zufen WangZufen Wang
Zufen Wang
LSLi Song
Li Song
An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable frequency drives (VFDs) makes the motor efficiency data published by manufacturers inapplicable, the fan efficiency and drive (belt-motor-VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD-motor-fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency and drive efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then the energy model is identified for an existing VFD-motor-fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD-motor-fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.