Shaomin Zhang

Shaomin Zhang

Auto-generated profile, based on publicly available information

Shaomin Zhang

Department of Biomedical Engineering, Qiushi Academy for Advanced Studies, Zhejiang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GWGuangming Wang
Guangming Wang
Sameul ZhangSameul Zhang
Sameul Zhang
SDShurong Dong
Shurong Dong
DLDong Lou
Dong Lou
LMLie Ma
Lie Ma
JLJikui Luo
Jikui Luo
Objective: Continuous measurement of key physiological parameters, such as heart rate (HR), pulse oxygen saturation (SpO 2 ), and sweat pH value, has very broad applications in healthcare, disease surveillance, and fitness and sports training. In this study, a stretchable optical sensing patch system was developed for real-time continuous noninvasive monitoring of the HR, SpO 2 , and sweat pH, and the sensing data were transmitted to a smartphone through Bluetooth. Methods: The sensor patch system adopted serpentine stretchable interconnects between the optical sensor and microcontroller chip with wireless function on a flexible substrate. The pH sensing function was implemented by coating a pH sensitive organically modified silicate film on the surface of a commercial blood oxygen sensor, achieving simultaneous measurement of HR, SpO 2 , and sweat pH with a single sensor. Results: Real-time on-body assessment was carried out to evaluate the sensor patch system, showing its excellent repeatability and applicability. The sensor patch system could withstand up to 35% extension and exhibited a pH sensitivity of 4.42 mV/pH from 4.0 to 8.0, while the accuracy of HR from 25 to 250 b/min and SpO 2 from 70% to 100% sensing were ±1 b/min and ±2%, respectively. Conclusion: The triple sensing functions was achieved through a single optical sensor on a flexible substrate while holding excellent contact with the body. Significance: The sensor patch system can be used for fitness guidance, skin disease detection, and wound monitoring and management by replacing related sensitive films.

12 July 2023 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
JMJiaxiang Mu
Jiaxiang Mu
ZYZikun Yang
Zikun Yang
Qi ZhangQi Zhang
Qi Zhang
XYXiyi Yuan
Xiyi Yuan
GWGuangming Wang
Guangming Wang
WSWenjun Sun
Wenjun Sun

9 January 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HGHaonan Guan
Haonan Guan
TFTao Feng
Tao Feng
MWMinmin Wang
Minmin Wang
MMMingwei Ma
Mingwei Ma
XYXingwang Yong
Xingwang Yong
Yi ZhangYi Zhang
Yi Zhang
The measurements of magnetic flux density ( $\emph {B}_{\emph {z}}$ ) measurement needed in magnetic resonance electrical impedance tomography (MREIT) and magnetic resonance current density imaging (MRCDI) techniques often utilize spin echo (SE)-based sequences for data acquisition. The low imaging speed of SE-based methods significantly hampers the clinical applications of MREIT and MRCDI. Here, we propose a new sequence for substantially accelerating the acquisition of $\emph {B}_{\emph {z}}$ measurements. A skip-echo acquired turbo spin echo (SATE) imaging sequence based on the conventional turbo spin echo (TSE) technique was proposed by adding a skip-echo module in front of the TSE acquisition module. The skip-echo module consisted of a series of refocusing pulses without acquisition. In SATE, amplitude-modulated crusher gradients were used to remove the stimulated echo pathways, and the radiofrequency (RF) pulse shape was specially selected to preserve more signals. In efficiency evaluation experiments performed on a spherical gel phantom, we demonstrated that SATE had improved measurement efficiency compared to conventional TSE and multi-echo injection current nonlinear encoding (ME-ICNE) sequences via skipping one echo before acquiring signals. The accuracy of the $\emph {B}_{\emph {z}}$ measurements by SATE was validated against those by the ME-ICNE method, while SATE was able to accelerate the data acquisition up to 10-fold. Volumetric coverage of $\emph {B}_{\emph {z}}$ maps obtained in the phantom, pork, and human calf illustrated that SATE can reliably measure volumetric $\emph {B}_{\emph {z}}$ distributions within clinically acceptable time. The proposed SATE sequence provides a fast and effective approach for volumetric coverage of $\emph {B}_{\emph {z}}$ measurements, greatly facilitating the clinical applications of MREIT and MRCDI techniques.

20 May 2026 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
YXYuchen Xu
Yuchen Xu
CLChenyang Li
Chenyang Li
MWMinmin Wang
Minmin Wang
Yun-Hsuan ChenYun-Hsuan Chen
Yun-Hsuan Chen
SZShaomin Zhang
Shaomin Zhang
Mohamad SawanMohamad Sawan
Mohamad Sawan
!Lower extremity motor function deficits, combined with fatigue, are common in patients with neurological injuries. The interaction between motor deficits and fatigue further limits rehabilitation endurance and recovery. However, how different types of movement are modulated by the cortico-muscular network in response to a fatigue remains unclear. In this study, ten healthy subjects were recruited to perform sit-to-stand tasks (T1: concentric sit-to-stand, T2: eccentric stand-to-sit) in both pre-fatigue and post-fatigue states. During these tasks, electroencephalogram (EEG) and electromyogram (EMG) signals from the lower extremities were recorded. Muscle and mental fatigue were confirmed by EMG mean power frequency (MPF) and changes in EEG Lempel-Ziv complexity (LZC). Inter-cortical and cortico-muscular networks were analyzed using generalized partial directed coherence (GPDC), with clustering coefficient (CC) and global efficiency (GE) as network metrics. In the pre-fatigue state, T1 exhibited greater inter-cortical network connectivity compared to T2. In the post-fatigue state, T1 increased inter-cortical connectivity while T2 showed significant increases in CC and GE in the beta band (P=0.018, P=0.034). At the cortico-muscular level, T1 shifted the descending pathway from Beta band to Gamma band while T2 significantly upregulated the strength of descending cortico-muscular pathway and ascending pathways in both Beta and Gamma bands. These findings indicate concentric movements exhibited more compensation in inter-cortical connectivity and band shift in cortico-muscular network, while eccentric movements showed greater efficiency in inter-cortical level and stronger cortico-muscular network strength. This study reveals distinct modulation patterns for concentric and eccentric movements under fatigued conditions, which may provide insights for developing targeted training and therapeutic programs for rehabilitation.