7 July 2025 in IEEE Transactions on Instrumentation and Measurement
The assembly accuracy of motion axis of machine tool is determined by multi parameters, including geometric errors of linear guides and parallelism between multi axis, named error equalization effect. This article proposes a multi-functional laser calibrator, which is consisted of a novel five degree of freedom measurement (5-DOFM) system and a dual-axis precision level with a pentagonal prism. The geometric errors of linear guide (including straightness errors, pitch, yaw and roll angular errors) and parallelism between multi axis could be detected conveniently. Especially, the influence of the pentagonal prism on parallelism measurement was investigated and proved using reflection matrices. A series of validation experiments were conducted to demonstrate the effectiveness of laser calibrator. The experiments results reveal that designed laser calibrator can achieve measurement range of ± 150 um for straightness errors detection, and ± 200″ for angular errors detection. The measurement error of parallelism between multi guide rails can be controlled less than 1″ (5 um/m) according the analysis results of the pentagonal prism. The proposed instrument can provide numerical reference for the research of motion axis error equalization effect and the improvement of assembly accuracy.